Get support for Hunter 44860

Hunter 44860 Support Question

Hunter 44860 Support Question

Find answers below for this question about Hunter 44860.
Need a Hunter 44860 manual? We have 2 online manuals for this item!
Question posted by bbtrso on April 16th, 2014

Does Black Wire Black Go To Rh Or Rc For Hunter Thermostat

The person who posted this question about this Hunter product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Hunter 44860 Manual Pages

Owner's Manual - Page 1

Memphis, TN 38114 888-830-1326 www.hunterfan.com Hunter Fan 2500 Frisco Ave.
Owner's Manual - Page 2

Touchscreen Programmable Thermostat Model 44860 2 Stage Heat/2 Stage Cool installation and operation manual
Owner's Manual - Page 3

... 35 MANUAL OPERATION 36 PROGRAM OPERATION 39 PROGRAM OVERRIDES 46 ADDITIONAL FEATURES 56 CLEAN SCREEN 56 CHANGE FILTER 60 ENERGY MONITOR FUNCTION 64 TROUBLESHOOTING 68 WIRING DIAGRAMS 72  44002-01 r051807
Owner's Manual - Page 4

Please read this manual before beginning installation and save this booklet for choosing a Hunter programmable thermostat. Thank you for complete operating instructions.  Your new Hunter thermostat will provide years of reliable service and year-round energy savings. 44002-01 r051807 Touchscreen Programmable Thermostat Model 44860 2 Stage Heat/2 Stage Cool Congratulations!
Owner's Manual - Page 5

...Only Systems Single and Multi-Stage Heat Pumps Gas, Electric or Oil Systems Millivolt Systems 2-wire Hydronic Systems AC or Hard-wired This thermostat is not designed for use with 110V/220 V systems. If you are unsure of... Volt (AA) size alkaline batteries  44002-01 r051807 INSTALLATION PROCEDURES TOOLS This thermostat includes two #8 slotted screws and two wall anchors for mounting.
Owner's Manual - Page 6

The wires must be labeled prior to removal to ensure proper connection. 44002-01 r051807  RC Y G W RC Y G W w NOTICE OF CAUTION! DO NOT disconnect the wires from the existing thermostat before reading these instructions.
Owner's Manual - Page 8

... back into the wall during disconnection. Some models may have multiple covers, screws or other locking devices that open to access the wires from the wall. (Some thermostats may have doors that must be removed or disengaged.) 3. You may be capped with an approved electrical connector, such as you disconnect them. Locate...
Owner's Manual - Page 10

... HVAC technician. If the terminals are both present, "C" may be ignored. NOTE: Wire colors do not always comply with standards; If there is no "C" wire, the thermostat will run on battery power. 44002-01 r051807  therefore, wire color should be a Common wire and provides 24 VAC power to the unit. Connecting it greatly extends battery...
Owner's Manual - Page 11

... this sticker: if your existing thermostat is marked: label the wire with this sticker: Y1 / Y2 Cooling Stage 1 or 2 Y1 Y2 Y2 Y1 R/RC R / RC Cooling Transformer Power Supply R/RC W1 / W2 Heating Stage 1 or 2 W1 W2 W2 W1 C C 24 VAC Common (if available) C G G Fan G RH RH Heating Transformer Power Supply RH See pages 72-73 for a complete...
Owner's Manual - Page 12

... PUMP SYSTEMS label the wire with this sticker: if your existing thermostat is marked: label the wire with this sticker: Y1 / Y2 Compressor Stage 1 or 2 Y1 Y2 Y2 Y1 C 24 VAC Common C C O W2 Auxilliary Heat W2 W2 O Cool Mode Powered Reverse Valve O G Fan G G E Emergency Heat E E R/RC R / RC 24 VAC Power Supply R/RC B B Heat Mode Powered Reverse...
Owner's Manual - Page 14

... mark the wall for two holes. 44002-01 r051807 13 Remove the wall plate from the Hunter thermostat by gently pulling the wall plate from the back of the thermostat. 2. If the existing holes do not match those on the wall horizontally and pull the labeled wires through the opening. 3. MOUNTING THE WALL PLATE 1.
Owner's Manual - Page 16

... r051807 15 4. Remove the wall plate from the wall and drill two 3/16" holes where marked. 5. Reposition the wall plate on the wall, pulling the wires through the wall plate and into the holes until they are flush with the wall. 6. Verify that the wall plate is level.
Owner's Manual - Page 17

Terminal Shield Terminal Screw Jumper Wire 16 44002-01 r051807
Owner's Manual - Page 18

Loosen, but do not have both an RH and RC wire. Insert wires behind the black terminal shield. Push any extra wires individually in place. 2. otherwise, leave the jumper in electrical tape and carefully push them into the wall to the terminals as shown. Wrap the ends of any excess wire length back into the wall. Tighten each...
Owner's Manual - Page 20

... over the terminal and battery openings. If the thermostat does not snap into place easily, the unit may damage the terminal pins. Place the thermostat over the wall plate, aligning it will snap into the back of the thermostat. 2. NOTE: Do not force the thermostat onto the wall plate as this may not work...
Owner's Manual - Page 22

You can also operate the thermostat manually. 44002-01 r051807 21 You can program the thermostat to automatically readjust the temperature and airflow to settings that responds to program and use the pre-programmed default settings. GENERAL OPERATING INSTRUCTIONS Your new Hunter thermostat is a touch screen that you choose or you can use . The front...
Owner's Manual - Page 70

..., make sure the furnace blower door is installed between the RC and RH terminals. 6. Replace batteries. 7. My system continues to operate when the thermostat is not in the off . 5a. 5. Wait. The...on or off to the system. 5d. Make sure the thermostat is in permanent override mode. 5b. If your system has 4 wires, ensure the jumper is closed properly. 5f. Replace batteries....
Owner's Manual - Page 73

... (single stage): RH (jumper between RH and Rc/R), Y1, W1, G • 5-wire Heat/Cool System (single stage): RH, Rc/R (remove jumper between RH and RC/R), Y1, W1 G. • 2-wire Heat only (single stage): RH (jumper between RH and Rc/R), W1 • 3-wire Heat only (single stage): RH (jumper between RH and Rc/R), W1, G • 3-wire Cool only (single stage): RH (jumper between RH and Rc/R), Y1...
Owner's Manual - Page 74

Optional Jumper Conventional HVAC Systems RH RC/R C Y1 Y2 W1 W2 G Heat 24V Cool 24V Supply Supply Cool Cool Heat Heat Fan Stage 1 Stage 2 Stage 1 Stage 2 Control 24VAC Common (if available) 44002-01 r051807 73
Owner's Manual - Page 75

RC/R C Y1 Heat Pump Systems Optional Jumper Y2 W2 E O B G L 24VAC Supply Compressor Compressor Auxiliary Emergency Reversing Valve Reversing Valve Fan System Stage 1 Stage 2 Heat Heat Cool Heat Control Monitor 24VAC Common (if available) Number of wires connected depends on systems without an E wire. 74 44002-01 r051807 Not all terminals need to be connected...

Similar Questions

Wiring Question For Hunter Thermostat To Rheem Ac
I'm trying to connect a 5 minute universal hunter 44132 thermostat . I have a brand new Rheem AC. Ne...
(Posted by JeanPavlov 11 years ago)
Ask a New Question
Use the box below to post a new question about this Hunter product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hunter Manuals

Find free Hunter 44860 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hunter Reviews

View thousands of Hunter user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hunter customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hunter customer service rankings, employee comments and much more from our sister site.

Hunter Recalls

Find comprehensive Hunter recall information updated hourly on RecallOwl.com.