Hunter 23952 Support Question
Find answers below for this question about Hunter 23952.Need a Hunter 23952 manual? We have 4 online manuals for this item!
Question posted by Pattergd on February 7th, 2013
Glass Replacement
Where can I find a glass replacement for the Bolton 54" ceiling fan, model 23952?
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Hunter 23952 Manual Pages
Installation Guide - Page 1
..., available from outlet box. You have no larger than the minor diameter of outlet box.
If you to recess the outlet box a minimum of the fan. Ceiling Hole o e outlet box clearance hole is directly below the joist or support brace that will hold the outlet box and the full weight of...
Owner's Manual - Page 1
installation and operation manual for Hunter Ceiling Fans
TYPE 2 Models
42775-01 • 04/29/08 For Your Records and Warranty Assistance Model Name Catalog/Model No Serial No Date Purchased Where Purchased For reference also attach your receipt or a copy of your receipt to the manual.
Owner's Manual - Page 2
... SAVE THESE INSTRUCTIONS.
• Use only Hunter replacement parts. • To reduce the risk of personal injury, attach the fan directly to the
support structure of the building according.... . . . .12 9 • Operating and Cleaning Your Ceiling
Fan 16 10 • Troubleshooting 17
Welcome
Your new Hunter® ceiling fan is an addition to the outlet box and associated wall switch location....
Owner's Manual - Page 3
... building according to these instructions, and use sturdy 3/4" diameter pipe to the ceiling, recommended for a vaulted or angled ceiling
Support Brace
Low Profile Mounting Style
Ceiling Outlet Box
Low Profile Mounting fits close to assure stability and wobble-free performance. All Hunter fans use only the hardware supplied.
3 42775-01 • 04/29/08...
Owner's Manual - Page 4
... or electrician. Gathering the Tools
You will need help installing the fan, your Hunter fan dealer can do the following tools for safety, reliable operation, maximum efficiency, and energy savings. 1 • Getting Ready
To install a ceiling fan, be sure you begin installing the fan, follow all the instructions in sets, as they were shipped.
4 42775...
Owner's Manual - Page 5
... fasten a prominent warning device, such as a tag, to orient the ceiling plate so that the arrows printed on the ceiling plate are pointing toward the ceiling peak.
5 42775-01 • 04/29/08 • Hunter Fan Company
Isolator
Ceiling Plate
Step 2-2 Steps 2-3 - 2-5
For Angled Ceilings: Be sure to the service panel.
2-1. Thread the lead wires from...
Owner's Manual - Page 6
... with a wrench or pliers. Note: When the pipe and ball assembly is normal. CAUTION: The adapter has a special coating on the ceiling plate through the downrod.
3-3.
3 • Assembling and Hanging the Fan
3-1. Securely retighten the set screw on the adapter to use the enclosed optional downrod, follow Steps 3-9 - 3-13 on the next...
Owner's Manual - Page 7
...downrod.
3-13. Place the low profile washer (lip up toward the ceiling.
3-7. Optional Downrod Instructions:
Your Hunter fan comes with three low profile screws.
3-8. If you use the enclosed optional...8226; 04/29/08 • Hunter Fan Company Assemble securely with an optional downrod extension pipe. Note: The Perfect BalanceTM system is replaced with the holes in the rim. ...
Owner's Manual - Page 8
... the wire (ungrounded) for the wall switch
Single Switch Wiring: • The black wire (ungrounded) from the ceiling to the green ground wire (grounded) from the ceiling plate and the green ground wire from the fan. 4-5. Wall switches are visible after making connections.
4-6. Turn the splices upward and push them , then twist clockwise...
Owner's Manual - Page 9
...fan off the hook.
5-2. Step 5-2 Canopy
Should you need to the top of the canopy. Align the slots in , tighten them.
5-5. Using both hands, push the canopy trim ring up to remove the canopy trim ring, follow these steps:
1. Raise the canopy over the ceiling... plate. Once all three screws are in the canopy with the tabs on the ceiling plate totally engage with...
Owner's Manual - Page 10
...
Blade Iron Armature Screws
Step 6-3
10 42775-01 • 04/29/08 • Hunter Fan Company
Steps 6-1 - 6-2 Blade Assembly
Screw
Grommet
Blade Loosen the blade iron armature screws that are...possible with a screwdriver. If you used grommets, the blades may include blade grommets.
Your fan may appear slightly loose after screws are holding the shipping bumpers in , then lift them by...
Owner's Manual - Page 11
... the retaining screws in the mounting plate. Notch Steps 7-1 - 7-2
Switch Housing Mounting Plate
Red Retaining Screws
11 42775-01 • 04/29/08 • Hunter Fan Company Remove the retaining screw from the bottom of the red retaining screws is visible through the notch in their place and continue the installation...
Owner's Manual - Page 12
... plate.
8 • Completing Your Installation With or Without a Bowl Light Fixture
Your Hunter fan comes with the housing assembly screws.
8-4.
Align the keyhole slots in improper performance of the ... housing is to be installed ONLY with this fan model.
8-1.
Feed the upper plug connector through the center opening of the fan and will result in the housing with an...
Owner's Manual - Page 13
... and lower switch housings.
Lower Switch Housing
Plug Connector
Steps 8-6 - 8-7
Plug Connector Detail
Housing Assembly Screw
13 42775-01 • 04/29/08 • Hunter Fan Company 8 • Completing Your Installation With or Without a Bowl Light Fixture (Continued)
8-6. Align the side screw holes in the lower switch housing assembly. Place the...
Owner's Manual - Page 14
... chain through the hole in the metal disc. 8 • Completing Your Installation With or Without a Bowl Light Fixture (Continued)
Installing the Glass Bowl
8-8. Then, thread the fan pull chain through the hole in the center of the cover plate. 8-14. Align the holes in the center of the extra chain.) 8-11. Thread...
Owner's Manual - Page 15
.... Lower Switch Housing
Step 8-19
Male Dummy Terminal
Female Dummy Terminal
Cap Plug Button
Step 8-22
15 42775-01 • 04/29/08 • Hunter Fan Company Once you have uninstalled the light fixture, continue with step 8‑6.
Remove the light fixture from the lower switch housing, pulling
disconnected wires through...
Owner's Manual - Page 16
... is turned on , let it come in warm weather to the opposite position. 9 • Operating and Cleaning Your Ceiling Fan
9-1. Turn on the fan to cool the room with each other. The first time the fan is jerked. The chain uses a breakaway connector that separates if the chain is turned on , the components might...
Owner's Manual - Page 17
... the shipping bumpers.
If it appears the blades have become imbalanced, run your fan wobbles when operating, use the enclosed balancing kit and instructions to ensure it is cracked.
If your fan on , replace fuse, or reset breaker. 2. 10 • Troubleshooting
Problem: Nothing happens; Check the plug connection in the switch housing. 4. Push...
Owner's Manual - Page 18
... Housing Mounting Plate
If you must remove all 5 red retaining screws
under the switch housing mounting plate. Your new Hunter fan features an innovative, new breakthrough in ceiling fan technology known as dust and wear can cause one blade to become slightly off-balance over time, the Perfect BalanceTM mechanism works by Hunter...
Parts Guide - Page 1
... Hanging System Kit
Ceiling Plate Canopy Canopy... Bottom Cap Finial Switch Housing Cap Plug Button Male Dummy Terminal Female Dummy Terminal Light bulb / Bulb Glass Globe
Model # Asm. THIS PARTS GUIDE IS FOR REFERENCE ONLY. Hardware (Drawn to Scale)
x 1 x...Blade Assembly
Switch Housing Assembly
Fan Parts
(Not Drawn to ...98274-01 New Bronze
Part # 94945-30
23952 98274-02 Brushed Nickel
Part # 94945-09...
Similar Questions
Hello, I Have A Hunter Ceiling Fan Model 20715, I Need A Replacement Motor. Than
(Posted by abels999 1 year ago)
Hi - Need To Replace Remote For Hunter Ceiling Fan Model 21617. Where To Buy?
(Posted by 2r2plata925 2 years ago)
I Am Looking For A Replacement Globe For The 21564 Model?
(Posted by ginad57755 9 years ago)
How To Access The Capacitor In Hunter Fan Model 23856
how to access the capacitor in hunter fan model 23856
how to access the capacitor in hunter fan model 23856
(Posted by trioxyys 11 years ago)
I Need A Replacement Globe For A Hunter Model 21311 380 Fan. Any Vendors?
(Posted by stowns115 11 years ago)