Get support for Honeywell T8195B

Honeywell T8195B Support Question

Honeywell T8195B Support Question

Find answers below for this question about Honeywell T8195B.
Need a Honeywell T8195B manual? We have 2 online manuals for this item!
Question posted by ddeputycat on July 12th, 2012

Wire Schematics For A Honnywell T8195b 1009

Where can I get the schematics for how to install one. I need the wire color placing on the wall plate. Thanks

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Honeywell T8195B Manual Pages

Owner's Manual - Page 1

Heating/Cooling Thermostat and Subbase or Heating or Cooling Thermostat and Wallplate T8195A,B/Q682 OWNER'S MANUAL 69-0563-2
Owner's Manual - Page 2

... and cooling systems. During heating and cooling, this thermostat will automatically lower and raise the temperature in your ... sealed tube. This thermostat meets California Title 24 requirements-mandatory installation of energy savings with your new Honeywell thermostat. Read this control is your new thermostat. Do not place control in a sealed tube, do not place your local waste management...
Owner's Manual - Page 3

Table Of Contents PAGE Features Of Your Thermostat ...4 Setting The Temperature ...7 Setting Subbase Switches ...8 Inserting Timer Backup Batteries ...9 Setting The Timer ...10 Programming ...11 Troubleshooting ...14 Servicing The Thermostat ...21 Warranty ...23 3 69-0563-2
Owner's Manual - Page 4

... 4 69-0563-2 Controls high and low temperature at specific time of day as set timer for 24-hour dial. 8 PROGRAM INDEX WHEEL. Features Of Your Thermostat 1 FLIP-UP COVER. Provides accurate room temperature reading. 4 TEMPERATURE SETTING LEVERS. Must be inserted into 24-hour timer dial slots to match the correct a.m. or...
Owner's Manual - Page 5

Provides mounting base and wiring connections for program pin insertion. 11 MERCURY BULB AND BIMETAL ELEMENT (2). 5 6 9 11 12 M8744 10 8 7 M8745 10 PIN SLOTS. Provide automatic temperature control by switching the heating or cooling system on 24-hour dial at 10-minute intervals for heating or cooling thermostat without system or fan switching...
Owner's Manual - Page 6

13 Q682 SUBBASE. Provides mounting base, wiring connections and manual switching control for heating/cooling thermostat. 13 R G FAN ON AUTO O B W Y HEAT COOL OFF M1551 6 69-0563-2
Owner's Manual - Page 8

...fan switch controls fan operation as follows: HEAT-Heating system is controlled by the thermostat. OFF- If the fan switch is at the AUTO position, the fan ... operates continuously. Switch lever must stop in heating and cooling. Heating system is controlled by the thermostat in the detent over desired function indicator mark for proper circuit operation. 8 69-0563-2 AUTO-Fan ...
Owner's Manual - Page 9

... Energizer® batteries. Once a year or when batteries are dead, replace with two new AAA alkaline batteries. INSTALL WITH POSITIVE ENDS UP M8585 Fig. 2-Inserting timer backup batteries. 9 69-0563-2 Install the batteries in the thermostat as shown in Fig. 2. Inserting Timer Batteries (Optional) Power is interrupted due to the timer by the...
Owner's Manual - Page 10

... 24-hour program dial, slotted in 10-minute increments. When Daylight Savings Time ends, carefully move the knob clockwise one hour. Setting The Timer Lift thermostat flip-up cover and you will point to the correct time and corresponding daytime (light) or nighttime (dark) band of the program dial. PROGRAM DIAL...
Owner's Manual - Page 11

...period. 24-HOUR PROGRAM DIAL (GRAY AREA FOR NIGHT SETTINGS) FLIP-UP COVER PROGRAM PINS THERMOSTAT COVER PROGRAM PIN SLOT PROGRAM INDEX WHEEL TIME INDICATOR ARROW PROGRAM PIN STORAGE M7348 Fig. 4-...p.m. We recommend at 6:00 a.m. for high temperature (comfort period); You can program your thermostat. the blue pins start the high-temperature period; Programming You can set up cover and you...
Owner's Manual - Page 14

Off. - R and W thermostat connections. Repair any frayed or broken wires. Check for correct terminal hookups. May be out. May be Move...in OFF or COOL position. 1 - Turn Off power to HEAT position. fuse or circuit breaker. Troubleshooting Your Honeywell thermostat requires little or no attention. May be traced to ON. furnace power switch. pilot flame. If blown or tripped...
Owner's Manual - Page 17

...Move switch to ON position. If fuse is On. system switch. other Timer is Off. Repair any frayed or broken wires. Reset clock. (continued) 17 69-0563-2 Move to COOL position. Make sure power is losing time. - fuse or... (continued) Problem Check No cooling. 1 - Turn Off power to cooling system. Y and R thermostat connections. - Firmly tighten all terminal screws.
Owner's Manual - Page 18

... on equipment may be clogged. Safety limit on safety. Wire separate transformer to page 19 for cause and action. (continued) 18 69-0563-2 Refer to power clock. Troubleshooting (continued) Problem Timer is losing time (continued). Timer does not run. - Remove the thermostat from the wallplate or subbase, and measure the voltage. high...
Owner's Manual - Page 20

...15 to power the timer is Off. 2. Spring fingers on thermostat not making proper contact with proper secondary voltage. 1. Replace thermostat. 20 69-0563-2 Timer has failed. Replace wiring. 3. Install transformer with subbase terminals. 2. System power is inadequate. 2. Short in timer power supply wiring. 3. Transformer supplying power is burned out. Free or replace limit...
Installation Instructions - Page 1

...wire cutter/stripper or sharp knife, bubble level or plumb bob and line. a If thermostat...T8195B/Q682B,C, Y8224A Heating or Cooling and Heating/Cooling New Construction Thermostat, Wallplate and Subbase Installation Instructions for the heating, cooling, or heating/cooling system. Preparation Check thermostat and subbase (if used to Table 1 for thermostat... place control in the thermostat ...
Installation Instructions - Page 2

...wall behind doors and in the wallplate or subbase. unheated (uncooled) areas such as provided in an area with its accuracy. rough handling may be affected by lifting from setpoint. holes, and gently tap anchors into holes until needed... Installer must be pulled, a 4-wire heating/cooling requires five wires). hot or cold air from the sun or appliances. - Fig. 1-Unpack thermostat....
Installation Instructions - Page 3

...installation instructions furnished with your new subbase, refer to the Typical Wiring Diagrams section at the end of this publication. NOTE: All wiring must comply with the cover plate assembly. Plug the hole in the wall... strip the thermostat wire insulation as necessary. Fig. 4-Mounting wallplate or subbase on the subbase. MOUNTING SCREWS (2) M1554A 3 69-0564-3 WIRE WALLPLATE OR SUBBASE...
Installation Instructions - Page 4

...wire back into the mounting slots in the bottom corners of the thermostat base. Once a year or when batteries are removed. INSTALL... across terminals R and C. We recommend Energizer® batteries. Place the two tabs on the top inside edge of the base ... or subbase. MOUNT THE THERMOSTAT Note the tabs on the upper edge of the cover into the wall. FOR STRAIGHT CONNECTION- Subbase...
Installation Instructions - Page 6

.... REMEMBER: Your wiring must follow local electrical codes and ordinances. Push both temperature setting levers together at least 5° F [3° C] above room temperature. Place the system switch ..., or heating/cooling equipment. Fig. 11-Typical hookup for T8195B Thermostat and Q682C Wallplate in a convenient place for at least one complete cycle with the system switch in...
Installation Instructions - Page 7

...REQUIRED. 2 REMOTE INDICATION FOR FILTER OPTIONAL. M573B 7 69-0564-3 TIMER THERMOSTAT HEAT/COOL ANTICIPATOR H C FALL H C FALL SUBBASE SYSTEM SWITCH FAN ...COOLING RELAY 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. SWITCH M8606 TIMER THERMOSTAT HEAT ANTICIPATORS SUBBASE SYSTEM SWITCH H C FALL H C FALL COOL ANTICIPATORS FAN SWITCH HEAT OFF...

Similar Questions

Wire Color Question
The wire color listed for the terminals do not match the wire colors from my unit. The wires I have ...
(Posted by rbtx75098 8 years ago)
Replace T8195b
Old thermostat has R Y G wires but no markings on thermostat to indicate where each wire would go on...
(Posted by pkyoung 11 years ago)
Replacement For Honeywell Thermostat T8195b 1009
I am looking for replacement for honeywell thermostat t8195b 1009. The voltage to the thermostat is ...
(Posted by kjtriantafilo 12 years ago)
Ask a New Question
Use the box below to post a new question about this Honeywell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Honeywell Manuals

Find free Honeywell T8195B manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Honeywell Reviews

View thousands of Honeywell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Honeywell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Honeywell customer service rankings, employee comments and much more from our sister site.

Honeywell Recalls

Find comprehensive Honeywell recall information updated hourly on RecallOwl.com.