Get support for HP Integrity rx2660

HP Integrity rx2660 Support Question

HP Integrity rx2660 Support Question

Find answers below for this question about HP Integrity rx2660.
Need a HP Integrity rx2660 manual? We have 28 online manuals for this item!
Question posted by gokul72429 on December 27th, 2011

Finding Diag0 & Diag2 Lights Are Blinking How To Vector Reset

hp RX2660 SERVER spare p/n# AB419-69004 in the mother board we found diag0 & diag2 lights blinking and next to it it is mentioned as reset vector. how to reset the vector unable to find the vector reset switch.kindly advice

Current Answers

Answer #1: Posted by kcmjr on December 27th, 2011 1:50 PM
This answer was accepted by the poster of the original question.
kcmjr

Member since:
May 5th, 2011

Points: 4,254,255
1,090
points
There is no reset switch.  You should use the HP Insight Manager (came on a CD with the server) to review the errors and reset them.  The indicators can mean any number of things.

Also here for download.

http://h18013.www1.hp.com/products/servers/management/hpsim/index.html?jumpid=go/hpsim

All support manuals are here: https://support.hp.com/us-en?openCLC=true

 


Licenses & Certifications: Microsoft, Cisco, VMware, Novell, FCC RF & Amateur Radio licensed.

Related HP Integrity rx2660 Manual Pages

Information for HP Integrity Products - Page 1

...website: http://docs.hp.com Hardware Enterprise Servers, Workstations Systems Hardware High Performance Computing - HP shall not be liable for HP products and services are set forth in the express warranty statements accompanying such products and services. The only warranties for technical or editorial errors or omissions contained herein. Information for HP Integrity Products Information for...
HP Insight Manager WBEM Provider Events Reference - Page 11

...board number and slot number, contact HP support to other subsystems. Data being written or transmitted at the event log for additional information. WBEM EventID: 159. The server...has detected that there was shut down or reset caused by system firmware. Recommended Action: For... host bridge failure, contact your HP representative to be exited to find which sensor was determined to check...
HP Insight Manager WBEM Provider Events Reference - Page 12

... the operating system and hardware event logs to find out if there are correctly connected to processor,... an MCA event occurs that application. Recommended Action: HP recommends that process and contact the vendor of a ...reset. Watchdog timer expired - See the System Event Log (SEL). WBEM ProviderName: SEL02_IndicationProvider. Recommended Action: Reboot system to allow vector...
HP Insight Manager WBEM Provider Events Reference - Page 13

... systems, the CPU has failed selftest. If you find these events, replace that prevented EFI from the last time the system was unable to fail. Recommended Action: Replace CPU. Probable Cause... WBEM EventID: 210. WBEM ProviderName: FPL_IndicationProvider. If problem persists contact your HP representative for support. WBEM ProviderName: FPL_IndicationProvider. Probable Cause: A CPU has ...
HP Insight Manager WBEM Provider Events Reference - Page 15

...: FPL_IndicationProvider. SAL_B not in FIT table. NVRAM test fail. Interrupt vector out of IVT error. Probable Cause: An internal error has occurred....HP representative for support. Recommended Action: Reboot, if problem persists contact your HP representative for support. Console device failure. Recommended Action: Reset console device/system. Trap taken. Recommended Action: Reset...
HP Insight Manager WBEM Provider Events Reference - Page 56

...light on this problem. WBEM ProviderName: FPL_IndicationProvider. WBEM EventID: 829. Probable Cause: Invalidate NVRAM and reset... NVM was detected and the cell integration policy combined to cause the cell to... error context in every boot then contact HP Support personnel to allow its deletion. Recommended... was begun but firmware couldn't find a deleteable cell. WBEM ProviderName:...
HP Insight Manager WBEM Provider Events Reference - Page 64

... on unreachable cell Defective CPU Recommended Action: Contact HP Support personnel to confirm the CPUs, CC, and cell board are functioning properly. WBEM EventID: 1766. WBEM ... SR - 9/6/03 CC. Resetting the partition because a processor was not in the XIN error mask. WBEM ProviderName: FPL_IndicationProvider. Recommended Action: Contact HP Support to read the topology ...
HP Insight Manager WBEM Provider Events Reference - Page 83

... inconsistency exists or the server exhausted its internal resources and is unable to create an fPars EFI ownership variable for the CPU map is identified in the system firmware. WBEM EventID: 4676. WBEM ProviderName: FPL_IndicationProvider. WBEM ProviderName: FPL_IndicationProvider. Recommended Action: Contact your HP support representative. Reset server and reconfigure soft partitions...
HP Insight Manager WBEM Provider Events Reference - Page 84

...HP support representative to check the processor module or the system bus for the processor if an excessive number of an fPar discovered that an fPar failed to reset itself). WBEM ProviderName: FPL_IndicationProvider. WBEM ProviderName: FPL_IndicationProvider. The operating system has recovered from an interrupt or similar vector...environmental conditions inside the server. WBEM EventID: ...
HP Insight Manager WBEM Provider Events Reference - Page 85

...the IVT offset applicable to HP Customer Engineer. WBEM EventID:... System firmware was directed to reset using the ESIT DirectedfParResetAndMigrate() service...IPF firmware owned the processor interrupt vector table (IVT) at the time...Cause: An fPar was unable to the card. Unable to write to LBA SetDeviceMask... ProviderName: FPL_IndicationProvider. So the server boots in Arches Fabric Phase3...
HP Integrity Servers with Microsoft Windows Server 2008 R2 Release Notes v6.5 - Page 21

... is gracefully shut down, one . You can exhibit sluggish performance. Servers All Integrity Workaround HP recommends placing the 10Gb Ethernet cards in the SEL. Servers Superdome SX2000, rx8640, rx7640, rx6600, rx3600, rx2660 Workaround Run HPSUM with a workaround will be available soon on Integrity Servers Installation Guide. When the system is booted up, a type DC event...
Windows Integrity Management Agents Reference - Page 9

...reset. Recommended Action: Read the system logs to one of the redundant power supply units. The server is not operational and is in HPIFP02TRAP.MIB. Recommended Action: Check all boards...the system is connected to find which sensor was shut down or reset caused by system firmware. ... supply has failed. Recommended Action: Contact HP Support for this voltage rail. This may...
Windows Integrity Management Agents Reference - Page 11

...server to check the I /O host bridge failure, contact your server hardware, go and turn off the server immediately. Recommended Action: HP recommends that would have caused an INIT, TOC, or RESET...Action: For an I /O host bridge failure, contact your server hardware, go and turn off , entered by IPMI command. Recommended Action: Find cause of temperature anomaly and fix it . SNMP Trap:...
Windows Integrity Management Agents Reference - Page 15

...contact your HP representative for support. Recommended Action: Reset console device/system. Recommended Action: Reset console device...5083 in HPIFPTRAP.MIB. 5076 Error Interrupt vector out of range Probable Cause: An ...unable to memory. Recommended Action: Reboot, if problem persists contact your HP representative for support. Recommended Action: Reboot, if problem persists contact your HP...
Windows Integrity Management Agents Reference - Page 63

... to describe the problem. Probable Cause: PDH battery power is on unreachable cell Defective CPU Recommended Action: Contact HP Support personnel to troubleshoot cell board Investigate for additional chassis codes to sleep state Recommended Action: Reset would clear this issue SNMP Trap: hpevtBootRtnFromSwCpuNotAsleep - 9442 in HPIFPTRAP.MIB. 9440 Error FW will not handoff...
Windows Integrity Management Agents Reference - Page 82

... modules have been detected on the cell board. Recommended Action: Contact your HP support representative. Indicates invocation of an fPar discovered that an fPar failed to release critical resources within a reasonable time. Recommended Action: Reset the nPar. Probable Cause: NVRAM corruption of fPars specific database. Reset server and reconfigure soft partitions. Probable Cause: NVRAM...
Windows Integrity Management Agents Reference - Page 84

...unable to the NVRAM holding the EFI preferred-bsp variable Recommended Action: Reset the server...HP Support Representative to the card. Contact your HP Support Representative to LBA SetDeviceMask method fails. Data field: (XBC port 48) | (XBC ID 32) | (route). IPF firmware owned the processor interrupt vector...in HPIFPTRAP.MIB. 10940 Warning Couldn't find all the edges during a procedure ...
Windows Integrity Management Agents Reference - Page 89

...'s is over temp. Recommended Action: Check IO backplane power board. Recommended Action: Collect IPMI event logs, and contact your HP support representative to a cell being added by PS command. Faulted... - 11579 in HPIFPTRAP.MIB. 11581 Warning ArfOLAPreRendez() was unable to find a valid route to inspect the fabric and system firmware. Data field: bitmap of unreachable...
Windows Integrity Management Agents Reference - Page 100

... the original cause. The nPartition will be reset or powered off. Recommended Action: Collect IPMI events and contact your HP Support Representative to cause MP Bus communications failures... SNMP Trap: hpevt12VPCIFailonIOChass - 12255 in HPIFPTRAP.MIB. 12230 Warning System firmware was unable to clear the link error masks Probable Cause: This event does not indicate the...
Windows Integrity Management Agents Reference - Page 109

...] IPMI failure: could not obtain manufacturer name while reading inventory data for FRU board area serial number. 5 Error [Server Agents] IPMI failure: could not obtain board name and type while reading inventory data for FRU board area serial number. 5 Error [Server Agents] IPMI failure: could not obtain serial number type while reading inventory data for...

Similar Questions

How To Install Windows Server 2008 R2 On Hp Rx2660
how to install windows Server 2008 R2 on windows HP server RX2660
(Posted by kmine 9 years ago)
End Of Support
HP Server DL360e gen8. Please confirm end of support date for above-mentioned model
(Posted by pksrivastava 11 years ago)
No Power
power supply top right light blinking green red system light on front panel blinking second light ...
(Posted by kbostelman 12 years ago)
How To Reset Mp Console Of Hp Rp4440/9000 Server
I want to reset the Admin password of MP conslole
(Posted by vilasgnar 12 years ago)
Ask a New Question
Use the box below to post a new question about this HP product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

HP Manuals

Find free HP Integrity rx2660 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

HP Reviews

View thousands of HP user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls