Get support for Hayward EcoStar

Hayward EcoStar Support Question

Hayward EcoStar Support Question

Find answers below for this question about Hayward EcoStar.
Need a Hayward EcoStar manual? We have 3 online manuals for this item!
Question posted by kokfrmtx on January 22nd, 2014

Who Has Had Issues With Hayward Ecostar Pump

The person who posted this question about this Hayward product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Hayward EcoStar Manual Pages

EcoStar Manual - Page 17

Hayward EcoStar Pump SP3400VSP Thursday 1:27p 1725rpm 380 Watts Timer 1 timer will end at 11:45p
Technical Guide - Page 1

Variable Speed Pump and Drive Technical Guide © 2011 Hayward Pool Products Version 2 Drive FW 1.02 Interface FW 2.55 residential Interface FW 1.00 commercial
Technical Guide - Page 4

... be taken to insure the maximum flow does not exceed the capacity of pipe (L) between pump suction port and first elbow or fitting should be at least 5 times pipe size. Existing Pools: When installing the EcoStar on a new pool, care should be taken to ensure proper pipe and equipment sizing to equipment manuals for...
Technical Guide - Page 7

... Wire Terminal. Voltage: 230 VAC, 60Hz, Single Phase. 2. Figure 6 Conduit Connections There are two on the pump. Breaker, wire size would be connected first. Bonding Lug 8 AWG (6 AWG for an EcoStar that is data connected to a Hayward/Goldline control, voltage needs to come directly from a breaker in the control, or in the case...
Technical Guide - Page 8

Remove the interface assembly as shown (fig 7, 9, 10 & 11) and re-secure with the two screws (fig 7). Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Page 6 Installation-Interface removal/positioning The interface assembly on the EcoStar can be configured in four different positions. 1. Reposition interface assembly as shown (fig 8). 3. Remove the two screws as shown (fig 7). 2.
Technical Guide - Page 9

... interface (fig 12). 3. After removal of the interface assembly (Page 7) remove the plug connecting the drive to the interface assembly. Plug is included with the EcoStar and includes blank cover, mounting bracket and new terminal block for wall mount or control connection. 2. Installation-Interface /Wall mount 1. Wall mount kit is permanently...
Technical Guide - Page 12

... & DISPLAY) from the wiring compartment (fig 23) and the 4 connector data plug from the filter pump relay. Wire 7 on the pump to 2 on the controller, 8 on the pump to 3 on the controller and 1 on 7 EcoStar is data connected to a Hayward/Goldline control, voltage needs to come directly from a breaker in the control, or in units...
Technical Guide - Page 13

... Controls (Non Hayward/Goldline compatible software & third party controls) 1. Filter Pump Replay AUX Relay AUX Relay AUX Relay Fig 24 Page 11 Pump power (230 VAC) needs to be rated for the pump (fig 24). Cable used for data connections should be brought into the "line in" contacts on the Filter Pump Relay from a breaker...
Technical Guide - Page 24

... do not need to individual relays/Auxiliaries (fig 45). For EcoStar interface software v2.55 data linked to a Goldline/Hayward compatible software control pressing & buttons will only recognize address 1 (Pool Filter) and address 2 (Aux 1/ Spa Filter). For EcoStar interface software v2.51 data linked to a Hayward/Goldline compatible software control v4.20 or less will give...
Technical Guide - Page 25

... enable or disable the Low Temp Operation (Default is Fig 48 for drive protection only Page 23 Enabling this point you will turn on the EcoStar, if stopped, to set the Low Temp Speed ( fig 47). Programming-Configuration 15.
Technical Guide - Page 26

... this page. 18. Programming-Configuration If you will be the next to program. Otherwise continue with this point you have an HCP3400VSP or HCP3400VSPVR commercial EcoStar please refer to page 39 for directions on the next screen.
Technical Guide - Page 32

... not start unless one or more timers are using is an SVRS model and there is activated you are set, the pump will be replaced. 6. If the EcoStar you will go into the prime mode selected during operation Monday 1:30p 2500 RPM 2000 Watts Low Temp Operation 2500 RPM 2000 Watts Page...
Technical Guide - Page 35

Wiring Compartment Cover Interface Assembly Variable Speed Drive Figure 63 Motor/Fan Shroud Motor Page 33 The wet end disassembly of the drive and motor area for this guide. Disassembly/Assembly This guide will only cover the disassembly of the EcoStar is exactly like the standard TriStar pump.
Technical Guide - Page 41

... 39 If you enable this point (fig 78) you will be prompted to 3 hrs by pressing the & button. Password Protection-Commercial 1. If you have a commercial EcoStar you can enable or disable the Password Protection feature by pressing the button.
Technical Guide - Page 45

... voltage (page 4) and verify that the incoming line voltage has dropped below 185 VAC and pumps stops. If less than 264 VAC, correct incoming supply voltage. Indicates that it is within ... has overheated. Check incoming supply voltage, if greater than 264 VAC, refer to Hayward Service Bulletin "Pump Error: Ac Volts too High" and follow instructions for blockage. Page 43 Follow ...
Technical Guide - Page 46

...Fault Codes Code/Fault Drive Error Drive failed to lead. Pump will attempt to start the motor. If pump is displayed. Ohms reading should be no change check ...before stall error is being controlled via data link to be between terminal 1 with EcoStar and terminal 4 with Hayward/Goldline Control (page 10). If they are outside limits, replace motor. Indications Indicates...
Technical Guide - Page 48

...the interface and drive. The breaker is connected to a GL/Hayward control. ground and AC ground wire and interferes with the commands being ... wiring and breaker. Control reads "Pool bridge comm" This indicates interference on , the pump will ramp up and down in ... If not, replace motor. Disconnect the wires from the pump drive. EcoStar is tripping. It travels on the comm. Contact Clemmons ...
Technical Guide - Page 49

...EcoStar is connected and operating via GL/Hayward control. The EcoStar should be wired to the GL/Hayward control. Check the settings in Standalone mode. Page 47 Control reads "Pool bridge comm." The %/rpm reading does not match between GL/Hayward control and EcoStar. Be sure EcoStar...or load side of the filter pump relay in the control (page 20) EcoStar reverts to Standalone mode even ...
Technical Guide - Page 50

... Quick Clean button is connected and operating via the GL/Hayward control. When a command is wired and set to protect any plumbing or other devices to the pump, the EcoStar interface reads "Remote Stop Engaged". This indicates that the comm. bus plug on the pump interface do not work properly. The Speed buttons and...
Parts Diagram - Page 1

... Kit (Includes Union Nut, Union Connector, Union Gasket - 2 ea.) Union Gasket Pump Strainer Housing, 2" x 2 1/2" with O-Ring Bracket, Motor Support Riser Base Adapter... Motor Drive Wiring Cover Digital Control Interface Assembly Wall Mount Kit HAYWARD 28 25 24 Ctn. Pumps EcoStar™ SP3400VSP PUMP SERIES REPLACEMENT PARTS Parts for Pump Models: SP3400VSP, SP3400VSPVR 4 5 6 10 11 3 78 ...

Similar Questions

Hayworc Ecostar Pump.'keypad Failed' Erroer Message
Pump display shows this message. Keypad failed. Hayword ecostar is3400vsp pump.
(Posted by Harenhema 10 years ago)
Hayward Ecostar Pump Manuel Is Incomprehensible
Is there a better alternative to the Ecostar Pump manual that comes with the pump. It is very diffic...
(Posted by sschenk3 10 years ago)
Ecostar Pump Goes Into A No Flow Default When The Solar Heater Comes On
Solar pool heater comes on and the pump goes into no flow or loses prime and shuts down, how do we r...
(Posted by paul52278 11 years ago)
How Do You Connect A Polaris Into A Hayward Ecostar Pump?
I replaced a old pool pump with a hayward ecostar pump and now need to reinstall my polaris booster ...
(Posted by gayethompson 11 years ago)
Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward EcoStar manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.