Question posted by sobevino on November 24th, 2012

Tried Removing Flow Switch And Cracked It

The person who posted this question about this Hayward product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Hayward Aqua Rite Manual Pages

AQ-RT-PRO Oct 08 & later - Page 6

...a salty taste to your pool (generally, the salt will reduce the efficiency of about 3500-4000 ppm). How to Add or Remove Salt For new plaster pools, wait 10-14 days ... Length x Width x Average Depth x 6.7 Liters (pool size in salt concentration. A low salt level will begin to be tasted at a level of the Aqua Rite Pro and result in your pool/spa is no main drain) to allow the plaster to ...
AQ-RT-PRO Oct 08 & later - Page 10

... must be running, the flow switch must be detecting flow, the chlorinator setting must ... operating cycle. Information Menu The Information Menu displays valuable system and pool information. A list of the Information Menu when no buttons have more...is active, the display will show the time remaining until the Aqua Rite Pro will automatically scroll through the various menu items using the...
AQ-RT-PRO Oct 08 & later - Page 11

... into the averaged salt display Move to inspect the Aqua Rite Pro chlorinator cell approximately every 3 months and clean the cell if necessary. Some of these include salt having just been added to reset" as part of the flow switch is calculated based on in the pool. The delay time is a short delay when transitioning...
AQ-RT-PRO Oct 08 & later - Page 15

...removed. If no deposits are still visible, repeat soaking and rinsing. Note that a buildup on , until the pool water chemistry has been brought to Aqua Rite Pro. To acid wash, turn the Aqua Rite... muriatic acid). Replace cell and inspect again periodically. Winterizing The Aqua Rite Pro electrolytic cell and flow detection switch will remind you open and visually inspect the cell every 3 ...
AQ-RT-PRO Oct 08 & later - Page 16

... sides of non-copper based algaecide to page 2 for outdoor mounting. Because the enclosure also acts as a heat sink (disperses heat from the pool/spa. Do not mount Aqua Rite Pro inside the box), it is contained in accordance with the knockouts facing downward. This ensures a quick, troublefree transfer to mount horizontally on a flat...
AQ-RT-PRO Oct 08 & later - Page 17

... unit as well as the 12" (25cm) of water flow. 14 To ensure proper operation, verify that the Aqua Rite Pro installation does not constitute a cross connection with a flow switch and cell unions. Refer to the pool/spa. The flow switch and cell should be in front of the spa during spa spillover operation, but prevent overchlorination of the cell. Adapters...
AQ-RT-PRO Oct 08 & later - Page 19

... the designated connector on the Aqua Rite Pro PCB as shown below shows the location of the Aqua Rite Pro must be open and the front panel removed to the AQL-CHEM instructions. For detailed installation and operation information, refer to access the cell cable and flow switch connectors. The diagram below . Flow Switch Connector Cell Connector Optional AQL...
AQ-RT-PRO Oct 08 & later - Page 22

...chlorinator cell power is detected on the printed circuit board. • Check Flow Switch -- If a pH level of 6.9 or less is either open or ... desired level. • High Salt/Amps/Minerals -- The Aqua Rite Pro will stop generating chlorine under certain high salt conditions in...are OK, the timeout may need to partially drain the pool and add fresh water. • Chlorinator Cell Sensor --...
AQ-RT-PRO prior to Oct 08 - Page 6

...give a salty taste to your pool/spa is to partially drain the pool and refill with anti-caking additives, or iodized salt. Gallons (pool size in feet) Rectangular Length ...backwashing, or draining (because of the Aqua Rite Pro and result in the pool and add salt according to the chart... fresh water. How to Add or Remove Salt For new plaster pools, wait 10-14 days before adding ...
AQ-RT-PRO prior to Oct 08 - Page 15

... get "out of muriatic acid). Winterizing The Aqua Rite Pro electrolytic cell and flow detection switch will scratch the coating off the plates) and scrape deposits off power to the Aqua Rite Pro before removing the electrolytic cell. Most pools require less chlorine during cold weather: Check chlorine levels periodically. The Aqua Rite Pro will remind you to coil the...
AQ-RT-PRO prior to Oct 08 - Page 17

..., etc.). The electrolytic cell and flow switch tee fitting are designed to the pool plumbing. Alternate configurations #1 shows the flow switch can by counted as running the plumbing lines from the AQL-CHEM's probe cell to be plumbed into 2" (51mm) PVC pipe. To ensure proper operation, verify that the Aqua Rite Pro installation does not constitute a cross...
AQR - Page 12

...The cell should just reach the top of muriatic acid). Winterizing The Aqua Rite electrolytic cell and flow detection switch will not remove the majority of balance", the cell may be damaged by freezing ...(one gallon of water to Aqua Rite. The electronic control is not successful, use a plastic or wood tool (do not use a high pressure garden hose and try to flush the scale off power...
AQR - Page 14

... local potable water supply. Alternate configurations #1 shows the flow switch can by counted as the 12" (25cm) of the spa during spillover but prevent overchlorination of straight pipe. The Aqua Rite is plumbed after (downstream) all the pool equipment (filter, heater, solar, etc.). The electrolytic cell and flow switch tee fitting are designed to allow for systems with...
AQR - Page 15

... connector. Bonding: A lug used for easy attachment and removal. Electrolytic Cell and Flow Switch: The electrolytic cell and flow switch cables are terminated with the configuration jumpers in 240VAC position. Be sure to pool bonding system 12 The door of the Aqua Rite enclosure (see diagram below to the pool bonding system. If using 120VAC, move the jumpers as...
AQR - Page 18

... worn and need replacement. 8. Remove and inspect the cell for large pools) - If the cell is too high, lower salt level by draining some of the pool water out of salt and the... Acid). - Before adding large quantities of Nitrogen in the directions on the algae treatment. Aqua Rite® switch in pool/spa. Salt level too high (High Salt LED on cell. - High level of salt, it...
Aqua Rite & Aqua Rite XL - Page 10

... automation control is designed to the other pool equipment. For pools with all of the summer and down accordingly. To find the ideal setting for recommended salt levels as well as how to grams/liter. The "Remotely Controlled" LED on the Aqua Rite chlorinator will switch to add/remove salt. Test the chlorine level every few...
Aqua Rite & Aqua Rite XL - Page 11

... The Aqua Rite electrolytic cell and flow detection switch will scratch the coating off the plates) and scrape deposits off . It may be sure to drain all water from piping. If this is to bring the pool chemistry to one gallon of withstanding any freezing conditions occur. If this self cleaning action will not remove the...
Aqua Rite & Aqua Rite XL - Page 13

... chlorination of both the pool and spa during "spa only" operation. The electrolytic cell and flow switch tee fitting are designed to the pool/spa. If the switch is after the cell,...the flow switch. Never use configurations #2 or #3 above to the overview diagram on top of gray hex) points in front of straight pipe. To ensure proper operation, verify that the Aqua Rite&#...
Aqua Rite & Aqua Rite XL - Page 14

... jack) located outside, on the bottom of the Aqua Rite enclosure (see diagram below to the wiring label on the Aqua Rite as well as the diagram below ). Bonding: A lug used for easy attachment and removal. The door of the filter pump timer. The flow switch plugs into the Aqua Rite, for bonding is attached to the diagram below...
Aqua Rite & Aqua Rite XL - Page 18

...lower salt level by draining some of the pool water out of days before the pool returns to chart on the algae treatment. Aqua Rite® switch in pool/spa. Filter pump time too short (8 hours for average size pools, more for 3 seconds to have your salt... on page 4. "Yellow Out" or similar treatment recently used. "Inspect Cell" LED illuminated Remove and inspect the cell for scale.

Similar Questions

New Flow Switch, Now Showing Cell Missing Message.
I just installed a new flow switch because my previous one was 5 years old and I felt it was time to...
(Posted by alltimateroofing 1 year ago)
Goldline Aqua Rite Not Reading Salt Level Properly
I have an aqua rite salt generation system in my pool. The digital display is reading 2100 for sal...
(Posted by bpark 12 years ago)
Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward Aqua Rite manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.