Question posted by jdrb on September 2nd, 2012

Unit Does Not Cool

Worked very well for almost 2 years (installed new in October 2010).  Last night stopped cooling.  No odd noises or change in operation except for no cool air.  I can hear what sounds like the compressor turning on and fan goes to HIGH speed but no cool air, just ambient warm air.

Requests for more information

Request from Chattababy34 on September 13th, 2020 2:30 PM
did u ever get any information on ur unit not cooling? Mine is doing the same thing..

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related GE AZ61H12DAB Manual Pages

Owners Manual - Page 1

... # Serial # Find these numbers on a label behind the room cabinet on the base pan. IB-16 Installing the Zoneline ......... 17, 18 Optional Drain Kit 19 Preparation 11 Replacing an Existing Unit? ........ 12 Troubleshooting Tips ...... 20, 21 Normal Operating Sounds ......... 22 Consumer Support Consumer Support ........ GEAppliances.com Q QJ 0 N 0 0_ 0_ Safety Instructions...
Owners Manual - Page 2

...it is used. Replacing an existing unit? SAFETY PRECAUTIONS This Zoneline must be performed bg a qualified individual. • These R410A air conditioning sgstems require contractors and technicians to...or connector end. DO NOT use with a new power supply cord obtained from the manufacturer and not repaired. For details, see the Installation Instructions in this manual. A damaged power ...
Owners Manual - Page 3

... set temperature will decreasein the same manner. MODE--COOL--For cooling FAN--For fan-only operation HEAT--For heating OPERATION--ON/STOP--Turtnhse unit on or off to STOPand then restart the unit. If the flashing light reappears within 30 minutes, coil for 8 hours before the compressor and stops after the compressor cycles off. When the outdoor temperature is lower...
Owners Manual - Page 4

...position, some outdoor air will reduce the heating or cooling efficiency. Energy Tip...Air Direction To change the air direction. 4 Louvesrcrews Default position Flipthe louver insert 180° replace the screws and the room cabinet. Open position l When set at the closed position. Louverscrews Remove the room cabinet and flip the louver insert to use ..Seethe Installation...
Owners Manual - Page 5

Auxiliary controls on .To change modes, press AU,_SET('AU" appears on the display).Pressthe mode button on /off / B'_ - Removethe room cabinet. The COOLLED light on the main control will be turned ON or OFFwith the unit controls. This is shown in the second digit of the display for Mode I HEAT _7 Eu Load...
Owners Manual - Page 6

...turning the air conditionerONat 85% and OFFat 80%. ressMODEuntila 6 appears in the seconddigitat thedisplay.PressAUXSETtocontirmyour selectionand exitAUXSETmode,or pressMODEto continue settingotherfunctions. FAN HEAT FreezSe entineOl FF /COOL...WallThermostatP. NOTET: hesefunctions are active wheneverthe unit is plugged in, evenif the unit is in the STOPposition.Pressthe down arrowfor...
Owners Manual - Page 7

...isusedwhenthe unit is... is OFF. Damage or erratic operation may damage the Zoneline electronics. ...AUXSETmode. HighSpeed Fan Green- If the unit isducted,the DuctNode needsto be usedwith remotethermostatoperation...V AConly Solenoid(AZ61only) Green- E_] Turnoff and unplugthe unit. [] Removethe roomcabinet.Seethe ToRemovethe RoomCobinetsection. [_] Removethe screwfrom the...
Owners Manual - Page 8

... AConly J Green- Compressor White- o01 0o 0.1o I__J [-- NOTE:ThCe lass2 Nodesetting(Node6) mustbe setto ON"n" for the unitto operatewith a Class2 Remote Wall Thermostat. (Seethe installation instructions supplied with Heat...Forthis reason,the unitswill operate slightlydifferentlywhenconnectedto a remote thermostat.Thefollowingchart showsthe unit operation when connectedto a remotethermostat...
Owners Manual - Page 9

... door is not removable. Room Cabinet and Case Turn the Zoneline off and unplug before cleaning, i .... Base Pan In some areas of the outdoor coil. ji To clean the vent filter: IMPORTANT: This filter is open,access requiresthe removal of the unit), In some installations, dirt or other debris may be checked regularly...
Owners Manual - Page 10

...; Decreasecost of operation. • Saveenergu. • Prevent clogged heat exchanger coils. • Reducethe risk of the unit. To maintain...cooling, heating, airflow and efficiency of premature component failure. Careand cleaning. Air Filters To remove the air filters: 2 Air filters Pullup_ Dirty filter--Needs cleaning Clogged filter--Greatly reducescooling, heating and airflo_z Turn...
Owners Manual - Page 11

...unit is in the OFF position, there is not covered under the Warrantg. Disconnect the power to the electrical controls. Call 800.GE.CARES (800.432.2737) or visit our Websiteat:GEAppliances.com I Questions? Savethienssetructfionr s local inspector's use an extension cord with the owner. • Note to Installer - Installation Instructions Zoneline Air Conditioners...
Owners Manual - Page 12

... RAK601/602 Existing ducted installation: Replocement of condensotion forming bu instolling insulotion kit RAKgOIL,ovoiloble where you purchosed the unit. NOTE:There ore severol extro holes in the unit side flonges for importantinformation, Use the correct wall case This unit is ploced in o new ducted opplicotion using o duct kit, gou must olwoys turn Mode 7 to operote...
Owners Manual - Page 13

... Rating 15 20 30 Proper GE Power Cord with a power supplg kit or a junction box kit. The device should be installed using one of the following electrical subbases: Branch Circuit and Unit Amperage Rating 15 20 30 Proper GE Subbase Kit RAK204D15P RAK204D20P RAK204D30P* *Not approved for use of 208 or 230...
Owners Manual - Page 14

... inside the providedjunction box must be done in accordance with the following steps. Use the POWERCONNECTIONCHARTon page 16 to the "MAKE ELECTRICALCONNECTION TO THE UNIT" section. FOR SUBBASE INSTALLATION Electrical subbase kits are available to a branch circuit MUSTbe done bg direct connection in accordance with the selected subbase kit must be carefullg...
Owners Manual - Page 15

...bottom and driving the two screws until secure. Placethe junction box cover in the unit mating connector. Replacethe two screws removed earlier and tighten securelg. 15 Removethe junction...the sides are no loose connections or strag uninsulated wires exposed. 2. Installation Instructions MAKE ELECTRICAL CONNECTION TO THE UNIT m REMOVE JUNCTION BOX 1. Note how the tabs on the lower ...
Owners Manual - Page 19

..."A" screw for metal case or Type"B"screwfor moldecdase 19 Installation Instructions OPTIONAL--DRAIN KIT INSTALLATION Dry Air 25 Series models are designed to improve dehumidification by 25...air, there is a greater possibilitg that water will drip from dripping onto external building walls, we recommend the use of RAD10 Drain Kit. To prevent this water from the wall case than with a standard unit...
Owners Manual - Page 20

... and make sure that the yellow connector on the surface of heating operation of the heating element. • This can cause the unit to cycle off due to the compressor overload protector. • Outdoor grille must have been hot or cold. The air filter is waiting for the compressoroverload protector to reset. Consult your...
Owners Manual - Page 21

... page 5. The Smart Fan Au×iliarg • See Smart Fan - GEAppliances.com Problem The air is not always cool or hot during operation The air does not feel worm enough during heating operation The unit is not blowing out air The electric heating feature does not work Temperature display flashes Possible Causes The heat pump is normal.
Owners Manual - Page 22

... the compressor starts at any thermostat setting. 22 During the defrost cycle, both indoor and outdoor fans stop and start. Normal Operating Sounds pI NG! This will operate in the base pan during high humidity or on rainy days or when the humidity is due to change the room temperature. "CLICK" DRIP 6 WHIRl You may hear relays...
Owners Manual - Page 23

...year warranty, GEwill also provide, free of the original purchase dote is of the sealed refrigerating sgstem(the compressor,condenser,evaporator and all labor and related service to replace the defective part. If SOUhave an installation problem, or if the air conditioner...• In commercial locations, labor necessarg to move the unit to a location where it is accessible for any labor or...

Similar Questions

Az61h12dabw1
y does 6 of my units heater blow cold air no heat pumps in my units worked great last year ac great ...
(Posted by lancesgirl77 5 years ago)
Ge Aem12apw1 12000btu Air Conditioner
This a/c has stopped blowing cold air and its only 2yrs old. I've tried setting the unit on 75deg To...
(Posted by Nirpno 10 years ago)
Ask a New Question
Use the box below to post a new question about this GE product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

GE Manuals

Find free GE AZ61H12DAB manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

GE Reviews

View thousands of GE user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete GE customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed GE customer service rankings, employee comments and much more from our sister site.

GE Recalls

Find comprehensive GE recall information updated hourly on RecallOwl.com.