Question posted by wwwadmontes13 on February 17th, 2022

Fluke Error Rf

No display error r

Requests for more information

Request from wwwadmontes13 on February 17th, 2022 6:32 PM
what can i do to fix it

Current Answers

Answer #1: Posted by SonuKumar on February 18th, 2022 8:16 AM
This answer was accepted by the poster of the original question.
SonuKumar

Member since:
May 9th, 2021

Points: 16,609,790
1,090
points
https://dam-assets.fluke.com/s3fs-public/381_____cmeng0100.pdf

could remove battery and re- place again back .. if not it has to be taken service


Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful.

Regards,
Sonu
Your search handyman for all e-support needs!!

Related Fluke 381 Manual Pages

Fluke 381 Clamp Meter Product Datasheet - Page 1

... jobs that used to operate controls or remove protective equipment, all while watching real-time readings. clamp the Fluke 381 around a conductor, remove the display and walk across the room to require two people; 381 Remote Display True-rms AC/DC Clamp Meter with iFlex™ The first clamp meter with measurement accuracy • iFlex...
Fluke 381 Clamp Meter Product Datasheet - Page 2

...,000 Ω 500 Hz Resolution 0.1 A 0.1 A 0.1 A 0.1 V 0.1 V 0.1 Ω 0.1 Hz • Accuracy 2 % ± 5 digits 3 % ± 5 digits 2 % ± 5 digits 1.5 % ± 5 digits 1 % ± 5 digits 1 % ± 5 digits 0.5 % ± 5 digits Included Accessory 750 MCM or 2-500 MCM CAT III 1000V, CAT IV 600V 2 Fluke Corporation 381 Remote Display True-rms AC/DC Clamp Meter with iFlex™
Fluke 381 Users Manual - Page 1

Specifications are trademarks of their respective companies. All product names are subject to change without notice. All rights reserved. Printed in China. 381 Remote Display True-rms Clamp Meter Users Manual PN 3538357 July 2010 © 2010 Fluke Corporation.
Fluke 381 Users Manual - Page 4

381 Users Manual Display...17 Measurements...19 AC and DC Current (Jaw 19 AC Current (Flexible Current Probe 22 AC and DC Voltage 23 Resistance/Continuity 26 Inrush Current ...
Fluke 381 Users Manual - Page 5

... 1 Introduction XWWarning Read "Safety Information" before you use the Meter. This lets the display be removed from the measurement source. How to 2500 A ac) and larger cables that has a remote-display module and detachable iFlex (Flexible Current Probe). The Fluke 381 is a handheld, battery-operated Clamp Meter (the Meter) that traditional jawed meters cannot...
Fluke 381 Users Manual - Page 6

381 Users Manual • Singapore: +65-738-5655 • Anywhere in this manual or the protection provided by the Meter ...latched before operating the Meter. • Remove the test leads from the Meter before you use the Meter. Carefully look at www.fluke.com. A Caution identifies conditions and procedures that pose hazard(s) to the user; To see, print, or download the latest manual supplement...
Fluke 381 Users Manual - Page 10

... by TÜV Product Services. ; Do not apply to relevant Australian standards. - 381 Users Manual Symbol Meaning Symbol Meaning CAT III IEC Measurement Category III CAT III equipment has... from HAZARDOUS LIVE conductors is the LOWEST rating of test probe, test probe accessory, current clamp accessory, and the Meter is permitted. Note The Measurement Category (CAT) and voltage...
Fluke 381 Users Manual - Page 11

..., but are marketed for operation by Fluke Corporation could void the user's authority to operate the equipment. Remote Display True-rms Clamp Meter Radio Frequency Data...two conditions that can cause harmful interference to , personal computers, calculators, and equivalent electronic devices that interference will not occur in commercial, business and industrial environments. However, ...
Fluke 381 Users Manual - Page 12

..., and Backlight), complete remote control of the measures that the radio signal is docked on the Meter base and turned on. Different display modules can be synchronized to a Meter base at the same time. 8 381 Users Manual off and on, the user is encouraged to try to correct the interference by one...
Fluke 381 Users Manual - Page 14

... powers off , turn the Rotary Function Switch OFF and then back on the Meter. 10 381 Users Manual Hazardous Voltage Indicator When the Meter senses a voltage ±30 V or a voltage overload (OL), Y is shown on the display and the red high-voltage LED () on the Meter base illuminates to -reach areas...
Fluke 381 Users Manual - Page 16

... Low Battery Indicators The Meter uses two low battery symbols: Band Q. When B appears, the batteries in the display. 12 The Meter can capture this surge current reading. The Inrush function takes approximately 400 samples over a 100 ... Q is first powered on the Meter base will affect the readings. 381 Users Manual Inrush Inrush Current is surge current that occurs when an electrical device is...
Fluke 381 Users Manual - Page 18

... button or switch interaction and then shuts off . Hold button: freezes the display reading and releases the reading when pushed a second time. With subsequent pushes,...shows maximum input. 381 Users Manual Item A B C D E F G H I Table 2. This function works in current, voltage, and frequency modes. 14 Hazardous-voltage indicator Display release button Display Backlight button: turns ...
Fluke 381 Users Manual - Page 22

381 Users Manual Item A B Table 4. Min Max mode is present. RF signal is taken at the Flexible Current Probe. Continuity Hazardous voltage is active. 18 Display Description Item Inrush is active H Hold is active I C Volts J D Amps K E Ohms, DC, AC, Hz L F Main display M G Remote display low-battery symbol N O Description Meter base low-battery symbol ...
Fluke 381 Users Manual - Page 24

... Switch to zero the Meter. 3. View the reading on the display, indicating that the measurement is < 0.5 A, the center dot in the display icon X will be steady. 2. Note When the measured current is...Figure 4. 20 If measuring dc, wait for the display to stabilize and then push Z to the proper function. To measure ac or dc current: 1. 381 Users Manual Note Before zeroing the Meter, make sure...
Fluke 381 Users Manual - Page 25

Current Measurement with Jaw ghn04.eps 21 CAT 1000 V CAT 600 V 1000 A Remote Display True-rms Clamp Meter Measurements 6C01A0C0TV0A0TV 381 TRRMEMS OCTLEAMDPISPMLEATYER iFlex 1000 A Figure 4.
Fluke 381 Users Manual - Page 26

...22 When the Rotary Function Switch is in the correct position, Y shows on the display, meaning that you close to . De-energize the installation under test or wear suitable... follow these instructions: 1. Turn the Rotary Function Switch to other current-carrying conductors. 3. 381 Users Manual AC Current (Flexible Current Probe) XW Warning To prevent possible electrical shock or personal...
Fluke 381 Users Manual - Page 30

... Current Probe around the device's live wire. 3. Push E on the display. See Figure 7. 26 If the display reads OL, the circuit is being tested. 3. Inrush Current Measurement (Jaw... lead to K. 2. 381 Users Manual Resistance/Continuity To measure resistance or continuity: 1. Turn the Rotary Function Switch to the G terminal. 4. Turn on the Meter display. Measure the resistance by...
Fluke 381 Users Manual - Page 32

.... Clean the instrument case with the plastics used for cleaning. The frequency is displayed on the Meter to shift to A or D if the Flexible Current Probe is being used in...Meter, do not use aromatic hydrocarbons or chlorinated solvents for the measurement. 2. 381 Users Manual Frequency Measurement (Jaw and Flexible Current Probe) To measure frequency: 1. Turn the Meter Rotary Function ...
Fluke 381 Users Manual - Page 35

Fluke Part Number Battery, AAA 1.5 V 5 2838018 Battery Door - Display Module 1 3625529 Battery Door - Meter Base 1 3766406 Fluke 381 Remote Display 1 3766445 Soft Case 1 3752973 User Manual 1 3538357 31 Remote Display True-rms Clamp Meter User-Replaceable Parts User-Replaceable Parts Table 5. User-Replaceable Parts Description Qty.
Fluke 381 Users Manual - Page 42

381 Users Manual Flexible Current Probe Cable Length (head to electronics connector 1.8 m Environmental Specifications Operating Temperature 10 °C to +50 °C Storage ...50 °C) (Without Condensation) Operating Altitude 2000 meters Storage Altitude 12,000 meters EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006 ETSI EN 300 489 V1.8.1:2008 FCC ...

Similar Questions

Fluke 381
error en display rf
(Posted by Israelmxli 1 month ago)
I Am Getting An Rf Error, What Do I Do?
(Posted by bensalazar7164 1 year ago)
Error Display
Hi.. why display error in screen for fluka 8846a dives when resistense measurment...
(Posted by sarmadali778 3 years ago)
Rf Error
I have a fluke 233 meter with an rd error what is the problem and how do I fix it
(Posted by tandctracksales 5 years ago)
Ask a New Question
Use the box below to post a new question about this Fluke product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 381 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.