How To Diseble Auto Power Off Mode ?

Current Answers

Answer #1: Posted by waelsaidani1 on June 23rd, 2013 12:47 AM
This answer was accepted by the poster of the original question.
waelsaidani1

Member since:
May 12th, 2013

Points: 19,501,797
1,100
points
PRESS THE YELLOW BOTTUN to Disable automatic power-down ("Sleep mode").
(PoFF)
Sleep mode is also disabled while the Meter is in a
MIN MAX AVG Recording mode, or the AutoHOLD
mode.

 

Related Fluke 179 Manual Pages

Fluke 73, 77, 175, 177, and 179 Digital Multimeter Datasheet - Page 1

...; Electronics 179 Multimeter and Deluxe Accessory Combo Kit • 179 and IR Thermometer Combo Kit Feature Max voltage True-rms Temperature Basic dc accuracy Backlight Min/Max/Avg ToolPak meter hanging kit with magnet 73 600 0.3 % 77 1000 0.3 % 175 1000 177 1000 179 179/TPK 1000 1000 0.15 % 0.09 % 0.09 % 0.09 % Opt Opt Opt Included Fluke 73...
Fluke Current Clamp Meters - You Can Guess Which Fuse is Bad or You Can Try This Application Note - Page 1

... Note You've got a bad fuse in min/max mode with an open phase. That's because a three-phase induction...troubleshooting is sometimes done on each phase: the phase with a clamp accessory. good indications of why the fuse opened. A damaged enclosure or ...circuit power is drawn from , how do you can try this method is particularly useful. From the Fluke Digital Library @ www.fluke.com...
Fluke Digital Multimeters - 10 Dumb Things Smart People Do When Testing Electricity Application Note - Page 2

.... • Appliance outlets with short connections to utility power. • Electricity meters, primary overcurrent protection equipment. • ...Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. All rights reserved. i.e., where low-voltage connection is made to service entrance. IEC 1010 applies to well pump. CAT I Electronic • Protected electronic...
Fluke Multimeters - ABCs of Multimeter Safety Multimeter Safety and You Application Note - Page 2

... circuits, they tend to low-voltage (< 1000 V) test equipment.  Fluke Corporation ABCs of a power distribution system into categories is based on the fact that a dangerous high-energy... as CAT I Electronic • Protected electronic equipment. • Equipment connected to (source) circuits in larger buildings. • Appliance outlets with higher power available and higher-energy...
Fluke Multimeters - ABCs of Multimeter Safety Multimeter Safety and You Application Note - Page 3

... CAT I electronic circuitry, whatever...built-in CAT I location could actually encounter dc voltages much higher than the power line ac voltages measured by the European Commission and mandated through your hand,... Independent testing Independent testing is not, therefore, a guarantee of multimeter safety Fluke Corporation  ABCs of independent testing. Why? UL 3111, for the presence...
Fluke Multimeters - ABCs of Multimeter Safety Multimeter Safety and You Application Note - Page 6

... Hook on the side of safety.  Fluke Corporation ABCs of multimeter safety Use protective equipment such as programmable controllers, it is common to find electronic circuits (CAT I . Second, test the ... proper lock-out/tagout procedures. remove watches or other hand, is CAT I ) and power circuits (CAT III) existing in close proximity. Wear flame resistant clothing, not ordinary work ...
Fluke Multimeters - Anatomy of a High Quality Meter Application Note - Page 2

... 2140271 A-ENG-N Rev A 2 Fluke Corporation Anatomy of valuable safety information and...whenever possible. typically covers electronic equipment • Protected electronic equipment • Equipment ...accessories. And a system is a meter flashing, "low battery." But a failing battery is not what you and a powerful electrical circuit is only as good as its accessories as the accessories...
FE 175,177,179 Users Manual - Page 1

Printed in USA. All rights reserved. ® Models 175, 177, 179 True RMS Multimeters Users Manual May 2003 (English) © 2003 Fluke Corporation.
FE 175,177,179 Users Manual - Page 3

...Contents Title Page Contacting Fluke ...1 "Warning" and "Caution" Statements 1 Unsafe Voltage...1 Test Lead Alert ...1 Battery Saver ("Sleep Mode 2 Terminals ...2 Rotary Switch Positions...2 Display ...3 MIN MAX AVG Recording Mode 4 Display HOLD and AutoHOLD Modes 4 YELLOW Button ...4 Display Backlight (Model 177 and 179 Only 4 Manual Ranging and Autoranging 5 Power-Up Options ...5 Making...
FE 175,177,179 Users Manual - Page 5

... or tests the following: ♦ AC / DC voltage & current ♦ Diodes ♦ Resistance ♦ Continuity ♦ Voltage & current frequency ♦ Temperature (Model 179 only) ♦ Capacitance Contacting Fluke To contact Fluke, call: 1-888-993-5853 in USA 1-800-363-5853 in Canada +31 402-678-200 in Europe +81-3-3434-0181 in Japan...
FE 175,177,179 Users Manual - Page 6

... Positions Switch Position Measurement Function K AC voltage from 3.00 mA to 1000 V. The Sleep mode is no function change or button press for 20 minutes. Common (return) terminal for 2...overload for 30 BA seconds maximum). Models 175, 177 & 179 Users Manual Battery Saver ("Sleep Mode") The Meter enters the "Sleep mode" and blanks the display if there is always disabled in the MIN...
FE 175,177,179 Users Manual - Page 8

...Backlight (Model 177 and 179 Only) Press to activate MIN MAX AVG mode. Models 175, 177 & 179 Users Manual MIN MAX AVG Recording Mode The MIN MAX AVG recording mode captures the minimum and .... ⇒ ⇒ h h Press MIN MAX to select DC mA, DC A, Hz, temperature (Model 179 only), capacitance, diode test. The backlight automatically turns off . ⇒ To exit and erase stored readings,...
FE 175,177,179 Users Manual - Page 9

...minute backlight timeout. (Model 177 and 179 Only) 5 Manual Ranging and Autoranging The Meter has both Manual range and Autorange modes. ⇒ In the Autorange mode, the Meter selects the range with...YELLOW) Disables automatic power-down the button indicated while turning the Meter from OFF to Autorange and Auto Range is in a MIN MAX AVG Recording mode, or the AutoHOLD mode. When you turn...
FE 175,177,179 Users Manual - Page 10

Warning To avoid electric shock, injury, or damage to the Meter, disconnect circuit power and discharge all high-voltage capacitors before XW removing the common test lead. when removing the test leads, remove the live lead; Models 175, 177 & 179 Users Manual Making Basic Measurements The figures on the following pages show how...
FE 175,177,179 Users Manual - Page 11

... Continuity HOLD MINMAX RANGE HOLD MINMAX RANGE Testing Diodes Good Diode HOLD MINMAX RANGE Making Basic Measurements Good Diode HOLD MINMAX RANGE Measuring Temperature (Model 179 Only) AIK06F.EPS HOLD MINMAX RANGE RANGE Vent 80BK1 Type K Thermocouple or Pipe Probe XWWarning: Do not connect 80BK1 to live circuits. AIK10F.EPS + _ Single...
FE 175,177,179 Users Manual - Page 12

... accurately measure distorted waveforms. Calculating True RMS converters require a certain level of range. Turn power OFF, break circuit, insert Meter in -circuit current measure- They do not affect the specified...AC HOLD MINMAX RANGE DC mA + + A CAT CAT AIK08F.EPS 8 Models 175, 177 & 179 Users Manual XW Measuring AC or DC Current Warning To avoid personal injury or damage to the Meter:...
FE 175,177,179 Users Manual - Page 14

XW Testing the Fuses Warning To avoid electrical shock or injury, remove the test leads and any input signals before replacing the fuse. Do not use abrasives or solvents. Models 175, 177 & 179 Users Manual Cleaning Wipe the case with a damp cloth and mild detergent. HOLD MINMAX RANGE 440 mA 11 A Test fuses as shown below. Dirt or moisture in the terminals can affect readings.
FE 175,177,179 Users Manual - Page 16

... to 1 kHz) 60.00 mA 400.0 mA 6.000 A 10.00 A 0.01 mA 0.1 mA 0.001 A 0.01 A 1.5 % + 3 1. Models 175, 177 & 179 Users Manual Function Range 1 Resolution Accuracy ± ( [ % of Reading ] + [ Counts ] ) Model 175 Model 177 Model 179 AC Volts 2,3 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V 0.1 mV 0.001 V 0.01 V 0.1 V 1 V 1.0 % + 3 (45 Hz to 500 Hz...
FE 175,177,179 Users Manual - Page 17

... input burden voltage (typical): 400 mA input 2 mV/A, 10 A input 37 mV/A. 5. Frequency is the specified accuracy of Reading ] + [ Counts ] ) Model 175 Model 177 Model 179 DC Amps4 60.00 mA 400.0 mA 6.000 A 10.00 A 0.01 mA 0.1 mA 0.001 A 0.01 A 1.0 % + 3 1.0 % + 3 1.0 % + 3 Hz (AC...
FE 175,177,179 Users Manual - Page 18

... Scale Voltage To: 600 kΩ 50 MΩ < 660 mV DC < 4.6 V DC 2.4 V DC Normal Mode Rejection > 60 dB @ 50 Hz or 60 Hz > 60 dB @ 50 Hz or 60 Hz Short Circuit Current...Fuse Overload 600 mA overload for 2 minutes maximum 20 A overload for high energy circuits. Models 175, 177 & 179 Users Manual Function Volts AC Volts DC mV/T Overload Protection 1 1000 V RMS 1000 V RMS 1000 V RMS2 Input...

Similar Questions

No Power After Battery Change
I left my meter on volts and it sat for about 6 months when I went to use it the batteries were obvi...
(Posted by Ragius 6 months ago)
My Fluke 381 Has A Poff Fault?
what is the poff fault ?
(Posted by ian43ld001 5 years ago)
Works Fine With Battery But Cannot Charge The Battery By Power Supply
If the battery is charged full it works fine. the problem is we cannot chrge the battery from the po...
(Posted by rahimm 6 years ago)
When Press Power Button Lcd Screen Flash But No Power On,battery Is 100% Charged
When press power button lcd screen flash but no power on,battery is 100% chargeWhat coud be the poss...
(Posted by rubenzip71030 7 years ago)
Ask a New Question
Use the box below to post a new question about this Fluke product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 179 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.