Get support for Dell PowerEdge 2950

Dell PowerEdge 2950 Support Question

Dell PowerEdge 2950 Support Question

Find answers below for this question about Dell PowerEdge 2950.
Need a Dell PowerEdge 2950 manual? We have 8 online manuals for this item!
Question posted by ivlgh on March 20th, 2014

Pe2950 Motherboard Battery Type How To Replace

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Dell PowerEdge 2950 Manual Pages

Installing a SATA Optical Drive - Page 3

...bezel. See "Removing a SAS Controller Daughter Card" in which a SATA optical drive is being replaced by a SATA optical drive. Before you begin this procedure, review the safety instructions that came... Drive These instructions apply to Dell™ PowerEdge™ systems to remove the system cover and access any of the optical drive. 6 PowerEdge 2900 and 1900 systems only: Perform the ...
Installing a SATA Optical Drive - Page 4

... interposer board attached to the optical drive. The pins on the interposer board release tab at the back of the drive. 4 Installing a SATA Optical Drive Replacing a PowerEdge 2950 or 2970 Optical Drive NOTE: If you are replacing an existing IDE optical drive, you are replacing an existing optical drive, do not require optical drive trays.
Installing a SATA Optical Drive - Page 5

... Drive in a PowerEdge 2950 or 2970 System 2 1 3 4 5 6 7 1 optical drive 3 interposer 5 SATA power cable 7 optical drive carrier 2 interposer release latch 4 SATA cable 6 carrier latch Replacing a PowerEdge 1950 Optical Drive NOTE: The replacement drive tray provided in the side of the SATA optical drive into the tray until the pins on the carrier align with the holes...
Installing a SATA Optical Drive - Page 8

... right wall of the chassis and replace the cable retention bracket over the cable. Figure 1-4. See Figure 1-4. 7 Route the SATA cable along the top of the system until the bracket detaches from the chassis slots. 6 Route the SATA cable in the cable channel in the PowerEdge 2950 and 2970 1 2 3 4 5 1 SATA_B connector on the...
Information Update - Page 3

Power 2950 II and PowerEdge 2950 III Systems 9 System Board Replacement - PowerEdge 2950 III Systems 9 Processor Upgrades - Safeguarding Encrypted Data 9 System Message Update 10 LCD Status Messages Update 15 Contents 3 New ... Key 6 Installing the Optional Internal USB Memory Key 7 Support for 8-GB Memory Modules - Contents Non-Optimal Memory Configurations 5 PowerEdge 2950 III -
Information Update - Page 9

...", your system, verify that your system is installed, the system only recognizes and displays 63.75 GB during POST. System Board Replacement - Safeguarding Encrypted Data On PowerEdge 2950 III systems using Windows Server® 2008, you can use encryption programs, such as the BitLocker utility, to upgrading your system is on the latest processor...
Information Update - Page 10

...: Only trained service technicians are authorized to store this recovery key. If you replace the system board, you must supply the recovery key when you restart your system...problem persists, see functionality. System Message Update Table 1-1 lists new system messages for the PowerEdge 2950 III system and the probable cause and corrective action when the message appears. shooting System ...
Information Update - Page 24

System Diagnostics Update In the Customize window of operating systems on the Server OS Install tab. System Support for Microsoft Windows 2000 If you to a ... System Build and Update Utility, Microsoft® Windows® 2000 is supported by the PowerEdge 2950 and 2950 II systems, but not by the PowerEdge 2950 III system. You cannot save the file to specify the diskette drive or USB memory ...
Information Update - Page 46

Microsoft Windows 2000 System Build and Update Utility Microsoft® Windows® 2000 将位于 Server OS Install PowerEdge 29502950 II PowerEdge 2950 III Customize Log output file pathname USB 46 信息更新
Information Update - Page 132

...; cat/sys/devices/system/cpu/cpuxx/cpufreq/scaling_ cur_freq • RHEL 3 9 Intel Xeon 54xx proc/cpuinfo RHEL 4 Microsoft Windows 2000 System Build and Update Utility Server OS Install OS OS Microsoft® Windows® 2000 PowerEdge 2950/2950 II OS PowerEdge 2950 III Customize Log output file pathname USB 132
Information Update - Page 157

Microsoft Windows 2000 Microsoft® Windows® 2000 이 Server OS Install(서버 OS PowerEdge 2950 III 대신 PowerEdge 29502950 II Customize Log output file pathname USB 157
Hardware Owner's Manual (PDF) - Page 6

... Drive 86 Removing and Installing an Internal SCSI Tape Drive 86 Removing and Replacing the Tape Drive Cable Retention Bracket . . . . 88 System Memory ... the Integrated NIC TOE 93 Processors 93 Removing a Processor 93 Installing a Processor 95 System Battery 96 Replacing the System Battery 96 Expansion-Card Riser Boards 98 Removing the Left Expansion-Card Riser Board 98 Installing the...
Hardware Owner's Manual (PDF) - Page 56

...a Drive Blank NOTICE: To maintain proper system cooling, all empty hard-drive bays must replace the carrier with the SAS backplane board. The interposer card provides enhanced functionality that makes ... Do not turn off or reboot your finger under the shrouded end of the following two drive carrier types: • SATA drive carrier - NOTE: It is free of the blank outward until it , you...
Hardware Owner's Manual (PDF) - Page 70

...panel cable from the electrical outlet. 2 Open the system. NOTE: If you are installing a replacement RAID card, do not remove the plastic cover protecting the card until after installation of daughter cards..., and disconnect the system from the sideplane board. Although the cabling for the two types of the card is different (the SAS controller daughter card has only one connector, while...
Hardware Owner's Manual (PDF) - Page 96

... a heat sink and pre-applied thermal grease with the same or equivalent type recommended by the manufacturer. See Figure 3-28. See your Product Information Guide... off the system, including any of a new battery exploding if it locks. System Battery The system battery is incorrectly installed. Replacing the System Battery CAUTION: Only trained service technicians are authorized to...
Hardware Owner's Manual (PDF) - Page 97

... and turn the system on the positive side of battery connector NOTICE: To avoid damage to the battery connector, you must firmly support the connector while installing or removing a battery. 5 Install the new system battery. Replacing the System Battery 1 2 3 1 positive side of battery connector 2 system battery 3 negative side of the connector. See "System Board Connectors...
Hardware Owner's Manual (PDF) - Page 118

... fault indicator is not resolved by replacing the battery, see your Product Information Guide for the time kept in the System Setup program, replace the battery. See "Using the System Setup ... program, the problem may be caused by software rather than by a defective battery. See "Using Server Administrator Diagnostics" on page 131. 2 Locate the faulty power supply. Action 1 ...
Hardware Owner's Manual (PDF) - Page 127

... • If you have a SAS RAID controller daughter card, replace the SAS RAID daughter card battery. If replacing the battery does not solve the problem, see the documentation for your Product...: When troubleshooting an expansion card, see "Getting Help" on page 147. See "Installing a RAID Battery" on page 54. Problem • Error message indicates a problem with an expansion card. •...
Hardware Owner's Manual (PDF) - Page 175

...'s RAM. Video drivers may be integrated into the system board or may need to your system's video capabilities. W - Watt-hour(s). Windows Server 2003 - ZIF - Universal Internet Exchange. uplink port - UPS - A battery-powered unit that plugs into an expansion slot. USB - A USB connector provides a single connection point for example. USB devices can display...
Hardware Owner's Manual (PDF) - Page 178

..., 142 PCI buses, 142 external devices connecting, 17 F fan bracket removing, 68 replacing, 69 features back-panel, 17 front-panel, 13 G guidelines expansion card installation, 76...98 memory, 90 memory guidelines, 89 optical drive, 82 power supply blank, 65 processor, 93, 95 RAID battery, 74 installing (continued) SAS backplane board, 104 SAS controller daughter card, 70 SAS hard drive in a ...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerEdge 2950 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.