Current Answers

Answer #1: Posted by MWatDell on May 25th, 2014 10:21 PM
This answer was accepted by the poster of the original question.
MWatDell

Member since:
November 17th, 2011

Points: 306,490
1,100
points
Hi macleve

Multi bit error on memory means there is a fault either on the memory module or the memory slot.

You will have to troubleshoot to identify the issue.

Please refer to this manual on Page 25:
ftp://ftp.dell.com/Manuals/all-products/esuprt_ser_stor_net/esuprt_poweredge/poweredge-2950_owner's%20manual_en-us.pdf

Hope this helps.


MW@Dell

Related Dell PowerEdge 2950 Manual Pages

Installing a SATA Optical Drive - Page 4

... the left side of the drive tray to release the interposer board connected to lock it into the corresponding holes in the same carrier. Replacing a PowerEdge 2950 or 2970 Optical Drive NOTE: If you must be replaced with the drive tray provided with the system is used for the SATA optical drive...
Installing a SATA Optical Drive - Page 5

...Optical Drive in a PowerEdge 2950 or 2970 System 2 1 3 4 5 6 7 1 optical drive 3 interposer 5 SATA power cable 7 optical drive carrier 2 interposer release latch 4 SATA cable 6 carrier latch Replacing a PowerEdge 1950 Optical Drive ... carrier align with the holes in the installation kit must be used with PowerEdge 1950 systems. If you are replacing an existing optical drive, do not reuse...
Installing a SATA Optical Drive - Page 8

... in the right wall of the system until the bracket detaches from the chassis slots. 6 Route the SATA cable in the cable channel in the PowerEdge 2950 and 2970 1 2 3 4 5 1 SATA_B connector on the system board. 4 Remove the cooling shroud.
Information Update - Page 1

Dell™ PowerEdge2950 Systems Information Update
Information Update - Page 3

... Systems 9 Processor Upgrades - Power 2950 II and PowerEdge 2950 III Systems 9 System Board Replacement - Contents Non-Optimal Memory Configurations 5 PowerEdge 2950 III - Safeguarding Encrypted Data 9 System Message Update 10 LCD Status Messages Update 15 Contents 3 New System Features 5 New Performance Features 5 New High-Efficiency Power Supply ...
Information Update - Page 5

... Update 5 The system clocks down the performance to continue or F2 for the channel. PowerEdge 2950 III - Non-Optimal Memory Configurations The POST may halt when a non-optimal memory configuration is detected and the following message is displayed: Non-Optimal Memory Configuration Press F1 to the slowest speed in the system. New System Features New...
Information Update - Page 9

... of dual-core Intel Xeon processors and 5300 and 5400 series of the hard drive. See support.dell.com for 8-GB Memory Modules - Safeguarding Encrypted Data On PowerEdge 2950 III systems using Windows Server® 2008, you can use encryption programs, such as the BitLocker utility, to upgrading your system. Information Update 9 Processor Upgrades...
Information Update - Page 10

... node modules are installed in a interleaving, or the configuration that node for additional information interleaving cannot be for the PowerEdge 2950 III system and the probable cause and corrective action when the message appears. Memory configuration does not support Node Interleaving. Table 1-1. If you are using the TPM with an encryption application, you...
Information Update - Page 15

... as a precautionary measure. Check the system event log for information only. Turn off and active errors are displayed. LCD Status Messages Update Table 1-2 lists updates to the LCD status messages that can occur on the PowerEdge 2950 III system and the probable cause for each message. For information on the SEL and configuring...
Information Update - Page 18

...) logging, in xx seconds by the BIOS. in the Hardware and does not resume Owner's Manual. See "Installing a RAC Card" in the Hardware that the memory had a System Memory" in the memory multi-bit error Hardware Owner's (MBE). logging further SBEs until the system is missing or disconnected. The system BIOS has See "Troubleshooting spared the...
Information Update - Page 24

...cannot save the file to specify the diskette drive or USB memory key where the test log file is saved. This operating system is included in the list of operating systems on the Server OS Install tab. System Support for Microsoft Windows 2000 If ... run the System Build and Update Utility, Microsoft® Windows® 2000 is supported by the PowerEdge 2950 and 2950 II systems, but not by the...
Information Update - Page 27

目录 29 PowerEdge 2950 III 29 29 29 全新 I/O 30 30 内部 USB 30 USB 30 支持 8 GB PowerEdge 2950 III 32 PowerEdge 2950 II 和 PowerEdge 2950 III 32 32 33 LCD 37 40 Memory 40 CPU Information (CPU 42 Integrated Devices 42 System Security 44 Serial Communication 45 目录 27
Information Update - Page 29

POST Non-Optimal Memory Configuration Press F1 to continue or F2 for Setup (按 F1 F2 DIMM DIMM PowerEdge 2950 III 全新性能 Intel® Xeon® 5400 系列和 5300 8 GB BMC 信息更新 29
Information Update - Page 33

...!!*** Error: Remote Access Controller 化失败 initialization failure *** RAC virtual USB devices may not be available... 表 1-1 列出了 PowerEdge 2950 III 表 1-1 信息 原因 纠正措施 Alert! RAC 卡"。 Invalid PCIe card found in the Internal_Storage slot! Memory configuration...
Information Update - Page 109

POST Non-Optimal Memory Configuration Press F1 to continue or F2 for Setup F1 F2 DIMM DIMM DIMM PowerEdge 2950 III Intel® Xeon® 5400 5300 2 個。 • 8 GB BMC 109
Information Update - Page 137

POST Non-Optimal Memory Configuration Press F1 to continue or F2 for Setup F1 F2 DIMM DIMM PowerEdge 2950 III Intel® Xeon® 5400 5300 • 8GB BMC 137
Information Update - Page 142

...! PCIe PCIe SAS 142 RAC Invalid PCIe card found in the Internal_Storage slot! 표 1-1 PowerEdge 2950 III 표 1-1 메시지 원인 Alert! Memory configuration does not support Node Interleaving. DIMM !!*** Error: Remote Access Controller initialization failure *** RAC virtual USB devices may not be available...
Hardware Owner's Manual (PDF) - Page 25

... CPU configuration failure. Memory Population Incorrect memory configuration. Check screen for specific error Memory population order messages. If no memory card is present, the "Crd #" string is left out of the DIMMs in the set implicated by "## & ##" has had a memory multi-bit error (MBE). Prog Timer Programmable interval timer error. Parity Error Parity error. See "Getting...
Hardware Owner's Manual (PDF) - Page 26

... E2111 E2112 E2113 E2118 E2119 I1910 I1911 Text Causes Corrective Actions SBE Log Disable Crd # DIMM ## The system BIOS has disabled See "Troubleshooting System memory single-bit error (SBE) Memory" on page 120. If no memory riser card is present, the "Crd #" string is left out of the connections in the See "Troubleshooting System FBD...
Hardware Owner's Manual (PDF) - Page 33

... kits directly from www.dell.com or your Dell sales agent to determine if single-bit or multi-bit errors were detected and replace the faulty memory module. See system battery. See "Troubleshooting System Memory" on page 118. DIMM y Ensure that all appropriate cables are securely connected to ensure compatibility. "Using the System Setup Program" on...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerEdge 2950 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.