Question posted by jyohn on October 15th, 2012

Poweredge 1900 With An Error W1228 Romb Batt < 24 Hr.

What part do I order and where can I order it from quickly

Current Answers

Answer #1: Posted by DellDanielMy on October 15th, 2012 11:55 AM
This answer was accepted by the poster of the original question.
DellDanielMy

Member since:
October 15th, 2012

Points: 5,490
1,100
points
Hello jyohn

The PERC internal controller battery kit part # is 312-0448

http://accessories.us.dell.com/sna/productdetail.aspx?c=us&l=en&s=dhs&cs=19&sku=312-0448

The external controller battery is part # F07FP

The part numbers are subject to change. You can order the internal controller battery online. The external controller battery can only be ordered through a sales rep.

Either battery kit will work with PERC 5, 6, or the H700/H800 series counterparts.

Thanks

#Iwork4Dell


Dell Enterprise Engineer | Social Media and Communities
Get Support on Twitter @DellCaresPro
Download the Dell Quick Resource Locator app today to access PowerEdge support content on your mobile device! (iOS, Android, Windows)

Related Dell PowerEdge 1900 Manual Pages

Getting Started Guide - Page 6

• Dedicated PCI slot for system ID and error messaging. • System ID button on the front and back panels. The systems ...Linux AS and ES (version 4) for Intel Extended Memory 64 Technology (Intel EM64T) • SUSE® Linux Enterprise Server 9 for the latest support information about specific features, see "Technical Specifications" on the back) capable of the system ...
Getting Started Guide - Page 12

...-RW/DVD NOTE: DVD devices are data only. VGA connectors 16 MB of DDR SDRAM 800 W 90-264 VAC, autoranging, 47-63 Hz 2320 BTU/hr maximum Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55 A per power supply for integrated 1-GB...
Hardware Owner's Manual (PDF) - Page 2

... strictly forbidden. Dell Inc. Other trademarks and trade names may be used in this text: Dell, the DELL logo, Inspiron, Dell Precision, Dimension, OptiPlex, Latitude, PowerEdge, PowerVault, PowerApp, PowerConnect, XPS, and Dell OpenManage are trademarks of EMC Corporation. disclaims any proprietary interest in any manner whatsoever without notice. © 2006 Dell...
Hardware Owner's Manual (PDF) - Page 3

... System Messages 23 Warning Messages 30 Diagnostics Messages 30 Alert Messages 31 2 Using the System Setup Program Entering the System Setup Program 33 Responding to Error Messages 33 Using the System Setup Program 34 System Setup Options 34 Main Screen 34 CPU Information Screens 37 Integrated Devices Screen 38 Serial Communication...
Hardware Owner's Manual (PDF) - Page 12

...so by qualified support personnel or by descriptive text. Provides system ID, status information, and system error messages. NOTE: If you turn off the system using the end of the system can be pressed...About Your System The power button controls the DC power supply output to AC power and an error has been detected, the LCD lights amber regardless of the buttons is pushed, the LCD panel...
Hardware Owner's Manual (PDF) - Page 16

... management software documentation. Setup program. Ambient system temperature is off and active POST errors are authorized to boot, press the System ID button for information defined by descriptive...SYSTEM NAME E1000 E1114 FAILSAFE, Call Support Temp Ambient E1116 Temp Memory E1210 CMOS Batt Causes Corrective Actions A 62-character string that includes a status code followed by ...
Hardware Owner's Manual (PDF) - Page 17

... persists, see "Getting Help" on page 109. LCD Status Messages (continued) Code E1211 E12nn E1229 E122B E122C E1310 E1410 Text ROMB Batt XX PwrGd CPU # VCORE 0.9V Over Voltage CPU Power Fault RPM Fan ## CPU # IERR Causes Corrective Actions RAID battery is... when the processor regulator(s) was enabled See "Getting Help" on page 131. Specified microprocessor is reporting a system error.
Hardware Owner's Manual (PDF) - Page 18

.... If the problem persists, ensure that your system's Getting Started Guide. processor protocol error. Table 1-4. Processors are properly installed. LCD Status Messages (continued) Code E1414 E1418 E141C... source, or the SEL is cleared using either Server Assistant or the BMC Management Utility. processor initialization error. specified power Supply" on page 118. Power ...
Hardware Owner's Manual (PDF) - Page 19

...F## PCI SERR Slot # The system BIOS has reported a Remove and reseat the PCI PCI system error on page 117. About Your System 19 Remove and reseat the PCI expansion cards. If the problem ...the specified power supply. Unknown Err The system BIOS has determined that there has been an error in slot #. If problem persists, see "Troubleshooting the Power Supply" on page 108. If...
Hardware Owner's Manual (PDF) - Page 20

...131. 20 About Your System Int Controller Interrupt controller failure. Prog Timer Programmable interval timer error. SIO Err SIO failure. See "Getting Help" on page 131. See "Getting ... No memory is not configurable. Mem Config Err Memory detected, but not usable. Error detected during memory configuration. Unusable Memory Memory is configured, but is installed in the...
Hardware Owner's Manual (PDF) - Page 21

...) Code E201F E2020 E2021 E2022 E2110 E2111 E2112 E2113 Text Causes Corrective Actions DRAC Config Dell remote access controller Check screen for specific error Memory population order messages. messages. Check screen for specific error messages. determined that DRAC cables and connectors are properly seated. System Memory" on page 110. Check screen for specific...
Hardware Owner's Manual (PDF) - Page 22

...is unable to determine the problem if multiple related errors occur. I1912 SEL Full System Event Log is a... overflow message. Controller Daughter Card Battery" on page 110. W1228 ROMB Batt < 24hr Warns predictively that is not installed in this table, see...the Northbound side has failed. See battery has less than 24 hours of an abbreviation or acronym used in socket 1....
Hardware Owner's Manual (PDF) - Page 23

... explanation of same type and size; Either of range, the LCD displays the fault; Error messages will remove fault messages and return the status indicators and LCD colors to the same...faults, you receive a system message that is not listed in a new SEL entry. • A new error event is detected. • A failure is automatically removed when that can occur and the probable cause and...
Hardware Owner's Manual (PDF) - Page 24

.... See "Memory" on must be installed in sequential order, page 80. beginning with Single-rank DIMM - DIMMs should be matched in sequential order beginning with reduced ECC protection. Pairs must be populated in...dual-rank DIMM will be persists, see "Troubleshooting System Memory" on page 110. 24 About Your System See with different cache sizes detected! If the problem rank of memory modules...
Hardware Owner's Manual (PDF) - Page 25

...Troubleshooting a Diskette Drive" on page 112. See "Memory" on page 33. FBD training error: The following branch has been disabled: Branch x The specified branch (channel pair) contains... If the problem persists, see "Troubleshooting a Diskette Drive" on page 110. !!*** Error: Remote Access Controller initialization failure*** RAC virtual USB devices may not be installed in ...
Information Update - Page 1

Dell™ PowerEdge1900 Systems Information Update www.dell.com | support.dell.com
Installing a SATA Optical Drive - Page 3

... for specific step instructions. b Remove the center fans and the center fan bracket. c Release the spring latch at the top of the optical drive. 6 PowerEdge 2900 and 1900 systems only: Perform the following steps. See your Hardware Owner's Manual. 5 Disconnect the data and power cables from the electrical outlet. 2 Remove the bezel...
Installing a SATA Optical Drive - Page 4

The pins on the carrier fit into place. The PowerEdge 2900 and 1900 systems do not reuse the interposer board attached to the old drive. 1 Pull ... tray provided with the system is used for the SATA optical drive. Preparing the Optical Drive Tray - Replacing a PowerEdge 2950 or 2970 Optical Drive NOTE: If you are replacing an existing IDE optical drive, you are replacing an existing...
Installing a SATA Optical Drive - Page 9

... in the optical drive kit and connect one end to the optical drive and the other to the SATA connector on the system board. For a PowerEdge 1900, use the SATA_B connector. - See Figure 1-5. - Installing the SATA Optical Drive - Installing a SATA Optical Drive 9 See "Closing the System" in your Hardware Owner's Manual. 11...
Installing a SATA Optical Drive - Page 10

.... 10 Reconnect the system to the SAS controller daughter card. 9 Close the system. See "Closing the System" in a PowerEdge 2900 or 1900 3 2 4 5 1 1 optical drive 3 SATA data cable 5 SATA power connector on SAS backplane (PowerEdge 2900 only) 2 SATA power cable 4 SATA connector on system board 8 Reconnect the cables to power and turn on the...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerEdge 1900 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.