Get support for Dell PowerConnect 6248

Dell PowerConnect 6248 Support Question

Dell PowerConnect 6248 Support Question

Find answers below for this question about Dell PowerConnect 6248.
Need a Dell PowerConnect 6248 manual? We have 5 online manuals for this item!
Question posted by kevcasem on August 21st, 2013

How To Upgrade Dell 6248 Firmware

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Dell PowerConnect 6248 Manual Pages

User's Guide - Page 19

... RJ-45 or SFP interfaces. The Dell PowerConnect 6224F switch supports 24 1000Base-FX SFP ports and 4 "combo" ports for RJ-45 or SFP interfaces. The Dell PowerConnect 6248P adds support for RJ-45 or SFP interfaces. The DellPowerConnect™ 6200 series are provided with hot swappable stack members. The Dell PowerConnect 6248 supports 48 1000Base-T copper ports...
User's Guide - Page 59

...expansion slots are also mounted on the rear. Rear Panel Each PowerConnect 6200 series switch provides an RS-232 maintenance port, on the rear of the switch. The right slot (Bay 2) can support a plug-in ...plug-in Dual 10GbE XFP module, a 10GBase-T module, or a CX4 module. PowerConnect 6224, 6248, and 6224F Rear Panel Dual 10G slots for XFP, CX4, or stacking modules Dual 10G slots...
User's Guide - Page 62

... by observing the LEDs. Create a stack by observing the LEDs. Power Supplies The 6200 series switches have one each on the top and bottom switches. 62 Hardware Description You can stack up to 12 PowerConnect 6224 and/or 6248 switches, supporting up to connect the remaining free ports, one internal power supply which requires standard...
User's Guide - Page 93

... console(config)# NOTE: HTTP and HTTPS services require level 15 access and connect directly to appear. Configuring Dell PowerConnect 93 NOTE: In the Web browser enable SSL 2.0 or greater for the page content to the configuration level... authentication local NOTE: You should generate a new crypto certificate each time you upgrade (install a new version of) the control software application on the...
Getting Started Guide - Page 7

... a standard 48.26-cm (19-inch) rack or left freestanding (placed on documentation and firmware. Unpacking the Switch Package Contents When unpacking each switch, make sure that the chosen installation location meets the following items are included: • One PowerConnect switch • One AC power cable • One RS-232 cable • One rack-mount...
Getting Started Guide - Page 19

... be assigned a Stack ID that has not already been assigned to the Factory Default Configuration. A switch can insert and remove switches to the switch that is complete, the Master Switch will take place. None of firmware, the switch will initialize the stack using the last saved system configuration file. System Initialization for the new Stack ID...
Getting Started Guide - Page 21

PC 6224P Getting Started Guide 19 PC 6248 Figure 1-3. PC 6224 Figure 1-2. Figure 1-1. Front Panels and LEDs This appendix describes the front panels and LEDs of the Dell PowerConnect PC6224, PC6248, PC6224P, PC6248P, and PC6224F systems. Front Panels The front panels of the PowerConnect 6200 series systems are shown in the figures below.
Getting Started Guide - Page 266

...port counters show stack-port diag show switch‬‬ ‫‪show supported switchtype‬‬ LED‬‬ LED Dell Power Connect PC6248P ,PC6224P ,PC6248 , PC6224‬ו‪.PC6224F -‬‬ PowerConnect 6200 ‫‪PC 6224‬‬ 1-1‬‬ ‫‪PC 6248‬‬ 2-1‬‬ ‫‪...
Release Notes - Page 1

..., functionality or design. All rights reserved. Dell Inc disclaims any products or specifications referred to herein to any manner whatsoever without notice. © 2003 - 2010 Dell Inc. DellPowerConnect™ 6224/6224F/6224P/6248/6248P PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Date: May 2010 System Firmware Version 3.2.0.6 Information in this document is prohibited...
Release Notes - Page 3

... MUST follow the procedure set forth in the Dell PowerConnect 6200 Series Release 3.2 Upgrade Procedure included in your switch becoming inoperable. NOTE: The PC6200 switches when stacked require that this release note be installed on every switch member. System Firmware Version 3.2.0.6 Page 1 It is recommended that the same version of firmware be thoroughly reviewed prior to installing or...
Release Notes - Page 4

... should upgrade to the DellPowerConnect™ 6200 Series Systems CLI Reference Guide and the DellPowerConnect™ 6200 Series Configuration Guide. Hardware Supported PowerConnect 6224 PowerConnect 6248 PowerConnect 6224F PowerConnect 6224P PowerConnect 6248P 2 System Firmware Version 3.2.0.6 NOTE: OMNM 4.1 will not discover the switches running firmware...
Release Notes - Page 5

...of CX-4/Stacking Modules This feature will allow the forwarding plane of the switch will function according to a number when RADIUS indicates the Tunnel-Private-...session. System Firmware Version 3.2.0.6 Page 3 In order to support this feature, VLAN names must be downloaded via TFTP are configurable as protocols for a supplicant. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes...
Release Notes - Page 7

...VLAN Allow the user to configure the voice VLAN DSCP parameter and set the DSCP value. System Firmware Version 3.2.0.6 Page 5 The feature prevents a class of man-in a VLAN). The miscreant ...default if using phones with IP multicast address. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ MLD Snooping (RFC2710) In IPv4, Layer 2 switches can use IGMP Snooping to limit the flooding...
Release Notes - Page 15

PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ Trap Configuration In previous versions of the software, configuration of the flags for configuring all trap flags. Also note that the keyword "trap" has changed . If your previous configuration had flow control disabled, you upgrade a switch to support long usernames. ¾ Flow Control Flow Control is...
Release Notes - Page 19

...command to accept control characters: 'a-z' | 'A-Z' | '0-9 System Firmware Version 3.2.0.6 Page 17 Re-enabled objects to the CPU IPv6 ...not be displayed. Added an object to indicate when the switch is understood correctly. Added a comment to the running -config...Updated the help string to the default. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Issues Resolved The following...
Release Notes - Page 21

...to the next valid radius server. System Firmware Version 3.2.0.6 Page 19 Unknown characters being displayed are for invalid credentials. The switch was assuming that the default named radius ...Upon setting the priority to 250 such that verifies the session state. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Description Cannot enter Daylight Saving Time from Web interface...
Release Notes - Page 25

PowerConnect 6224/6224F/6224P/6248/6248P Release Notes RADIUS Accounting Servers Title radius-server host acct Description The switches... is a dot1x unaware client. If upgrading from a previous release the modes will...switch waits before authorizing the client if the client is used to the DellPowerConnect...to disable banner acknowledge. System Firmware Version 3.2.0.6 Page 23 Default:...
Release Notes - Page 27

PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Known Issues Summary Non-configuration file getting read an invalid start-up and create a default startup configuration. Banner MOTD: The switches Console and Web ... not work when the name of their configuration files. System Firmware Version 3.2.0.6 Page 25 The command vlan protocol group expected a string in the area...
Release Notes - Page 31

...with mark cos and assign queue attributes. System Firmware Version 3.2.0.6 Page 29 ip default gateway is... for VLAN routing interfaces. User Impact This behavior is 256. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes LACP Description LAGs Supported VLAN Description vlan association ...the PowerConnect 6200 series switches. User Impact The maximum number of MAC-based VLANs is a known...
Release Notes - Page 33

.... agentStpPortRootGuard object Use agentStpCstPortRootGuard instead. To configure the authentication type, either upgrade the browser to the default, delete the server and add it back...ports which are always enabled and cannot be disabled. System Firmware Version 3.2.0.6 Page 31 PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Management CLI Description radius-server mode commands do...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerConnect 6248 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.