Get support for Dell PowerConnect 6224

Dell PowerConnect 6224 Support Question

Dell PowerConnect 6224 Support Question

Find answers below for this question about Dell PowerConnect 6224.
Need a Dell PowerConnect 6224 manual? We have 5 online manuals for this item!
Question posted by jamesemsp on November 27th, 2013

Can I Use Sfp And Copper Ports Simultaneously On Dell 6224

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Dell PowerConnect 6224 Manual Pages

Command Line Interface Guide - Page 46

show fiber-ports optical-transceiver 1166 test copper-port tdr 1167 64 Power Over Ethernet Commands . . . . . 1169 power inline legacy 1170 power inline powered-device 1171 power inline priority 1172 power inline traps 1173 ...
Command Line Interface Guide - Page 123

... deliver power. IC (Ethernet ) Enables/disables the ability of a copper cable attached to GC support legacy Ethernet powered devices. PE transceiver test copper-port tdr Diagnoses with TDR (Time Domain PE Reflectometry) technology the quality and characteristics of the switch to a port. When a lockout count is configured, a user who is logging in must enter the...
Command Line Interface Guide - Page 139

..., the CLI allows the user to another instance (inclusive). ranges and non-consecutive instances listed together. Using the CLI 139 To facilitate this function, any characters entered after the character are allowed For LAG, use "interface range port-channel 1-48". • When operating on a range of non-consecutive instances. For example, (1/g1, 1/g3...
Command Line Interface Guide - Page 1164

... example displays the estimated copper cable length attached to a port. show copper-ports cable-length Use the show copper-ports cable-length [interface] • interface - A valid Ethernet port. The full syntax is unit / port. Default Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines The port must be active and working...
Command Line Interface Guide - Page 1166

... EXEC mode User Guidelines The show fiber-ports optical-transceiver Port TX Temp Voltage Current Output Input LOS Fault Power Power ----- --- 1/g3 w OK OK 1/g4 OK E OK 1/g1 Copper ------OK OK ------E OK -----OK OK ----OK OK 1166 PHY Diagnostics Commands show fiber-ports optical-transceiver Use the show fiber-ports optical-transceiver [interface] • interface...
Command Line Interface Guide - Page 1167

... Input Power - Loss of signal test copper-port tdr Use the test copper-port tdr command in a report on the cable attached to a port. During the test shut down the port under test unless it is 120 meters. Syntax test copper-port tdr interface • interface - console#test copper-port tdr 1/g3 Cable is unit / port. Command Mode Privileged EXEC mode User...
User's Guide - Page 19

...19 The Dell PowerConnect 6224P adds support for RJ-45 or SFP interfaces. The DellPowerConnect™ 6200 series are provided with hot swappable stack members. The Dell PowerConnect 6224F switch supports 24 1000Base-FX SFP ports and 4 "combo" ports for RJ-45 or SFP interfaces. The Dell PowerConnect 6224 switch supports 24 1000Base-T copper ports and 4 "combo" ports for RJ...
User's Guide - Page 26

... VLAN classification rules are collections of one or more ports. When ASF is useful for large packets. For information about defining Protocol-Based VLANs, see "Configuring VLANs." Port-Based VLANs Port-based VLANs classify incoming packets to VLANs based on the state of the link of switching ports that comprise a single broadcast domain. This feature is...
User's Guide - Page 41

... home page, the tree view provides an expandable view of features and their components. • Device view - Using Dell™ OpenManage™ Switch Administrator 41 NOTE: The switch is used to the CLI by using the console port. Enter the switch's IP address (as a view of the home page, the device view is not configured with a default password...
User's Guide - Page 52

.... Bay 1 and Bay 2 Interfaces The DellPowerConnect™ 6200series switches support dual 10 Gb slot interfaces. These interfaces can also use the supplied serial cable (null-modem) to connect the switch to female DB-9 crossover cable. Connect the serial cable to a Terminal 1. Figure 3-4. Connecting the Switch to the switch's serial port. 3. Connect the serial cable to...
User's Guide - Page 56

...-sensing Full-Duplex RJ-45 Ports 56 Hardware Description Combo Ports PowerConnect 6248 with four RJ-45/SFP combo ports that have an auto-sensing mode for speed, flow control, and duplex mode. Figure 4-2. PowerConnect 6224 with 24 10/100/1000 Base-T Ports 10/100/1000Base-T Auto-sensing Full Duplex RJ-45 Ports Combo Ports The PowerConnect 6248 front panel provides...
User's Guide - Page 62

... can verify operation by observing the LEDs. You can verify operation by connecting adjacent units using the stacking ports on the next switch. 3. Ventilation System Three fans cool the PowerConnect 6224. See "System LEDs" on page 67 for information. Connect one internal power supply which requires standard AC. Create a stack by observing the LEDs. For...
User's Guide - Page 72

... necessary commands to the switch before using the autoconfig feature, do not use on the console line only. 1. However, to the switch console port, or through a Telnet connection. Starting the CLI To begin running the CLI, perform the following steps: NOTE: The following steps are using CLI commands. 72 Configuring Dell PowerConnect Start the switch and wait until the...
User's Guide - Page 90

... server. 2. DHCP Management VLAN ID 1 Routing Interfaces: Netdir Multi 90 Configuring Dell PowerConnect To retrieve an IP address from a DHCP server, perform the following steps: 1. Select and connect any port to a DHCP server or to a subnet that has a DHCP server on port 1/ g1 using CLI commands: console(config)#interface ethernet 1/g1 console(config-if-1/g1...
User's Guide - Page 156

..., see the PHY Diagnostics Commands chapter in the CLI Reference Guide. Use to a port. Table 6-21. Cable Tests Commands CLI Command show copper-ports cable-length show copper-ports-tdr show fiber-ports optical-transceiver test copper-port tdr Description Use to display the estimated copper cable length attached to display the optical transceiver diagnostics. Optical Transceiver...
Getting Started Guide - Page 10

Create a stack by connecting adjacent units using the stacking ports on the left side of the switches to be turned off as they are connected in each of the switch rear. Connecting Power Cable Assembling a Stack You can stack PowerConnect 6200 series switches up to 12 switches high, supporting up to a stack. 1 Install a separately purchased stacking module in...
Getting Started Guide - Page 12

... configure the switch via serial console, use the console port: • VT100-compatible terminal or a desktop or a portable system with a serial port, running VT100 terminal emulation software. • An RS-232 crossover cable with Microsoft Windows 2000, make sure that you obtain the most recent version of the user documentation from the Dell Support website...
Configuration Guide - Page 25

... pairs unterminated or grounded. System Configuration 25 The switch uses Time Domain Reflectometry (TDR) technology to determine the quality and characteristics of the following statuses are returned: • Normal: The cable is working . One of a copper cable attached to the stacking, 10G BaseT, or CX-4 ports associated with these plug-in the cable. •...
Configuration Guide - Page 26

... Test has not been performed 1/g5 Test has not been performed --More-- Example #1: Cable Test for Copper Ports console#test copper-port tdr 1/g1 Cable Status Short Cable Length 5m console#show copper-ports cable-length Port Length [meters] ---- 1/g1 Example #2: Show Copper Cable Length Use the show copper-ports cable-length command in Privileged EXEC mode to display the estimated...
Configuration Guide - Page 27

NOTE: The show fiber ports command is only applicable to the SFP combo ports and XFP ports (not the ports on the SFP+ plug-in milliWatts TX Fault - Internally measured transceiver temperature Voltage - Measured RX received power in module). Internally measured supply voltage Current - Example #3: Show Last Time Domain Reflectometry Tests Use the show copper-ports tdr command in Privileged...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerConnect 6224 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.