Get support for Dell PowerConnect 6224

Dell PowerConnect 6224 Support Question

Dell PowerConnect 6224 Support Question

Find answers below for this question about Dell PowerConnect 6224.
Need a Dell PowerConnect 6224 manual? We have 5 online manuals for this item!
Question posted by leoclsrini on December 28th, 2013

What Is The Password For Powerconnect 6224

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Dell PowerConnect 6224 Manual Pages

Command Line Interface Guide - Page 1322

...(SID) Model Identifier Management Preference Code Version Description This field displays the index into the database of the show supported switchtype 1 Switch Type 0x73950001 Model Identifier 6224 Switch Description PowerConnect 6224 Management Preference 1 Expected Code Type 0x100b000 Supported Cards: Card Index (CID 3 Model Identifier PCM8024 The following example displays the format...
User's Guide - Page 19

..." ports for RJ-45 or SFP interfaces. NOTE: Before proceeding, read the release notes for all features, see the software version release notes. The Dell PowerConnect 6224 switch supports 24 1000Base-T copper ports and 4 "combo" ports for RJ-45 or SFP interfaces. 1 Introduction This section describes the...
User's Guide - Page 56

... front panel provides 48 10/100/1000M Base-T RJ-45 ports and four RJ-45/SFP combo ports. Figure 4-1. Front Panel The PowerConnect 6224 front panels provides 24 10/100/1000M Base-T RJ-45 ports with four RJ-45/SFP combo ports that have an auto-sensing mode for ...
User's Guide - Page 59

... switch. The left slot (Bay 1) can support a plug-in Dual 10GbE XFP module, a 10GBase-T module, or a CX4 module. RS-232 management port DC power AC power Figure 4-7. PowerConnect 6224P... support a plug-in Dual 10GbE XFP module, a CX4 module, or a stacking module. Figure 4-6. PowerConnect 6224, 6248, and 6224F Rear Panel Dual 10G slots for XFP, CX4, or stacking modules Dual 10G slots...
User's Guide - Page 62

... stacking cables into either of the stacking ports of the devices are connected. 4. Use the remaining stacking cable to connect the switches. Ventilation System Three fans cool the PowerConnect 6224. Connect one of the switch rear. Create a stack by connecting adjacent units using the stacking ports on the LEDs. Power Supplies The 6200 series...
Getting Started Guide - Page 266

‫‪show stack-port counters show stack-port diag show switch‬‬ ‫‪show supported switchtype‬‬ LED‬‬ LED Dell Power Connect PC6248P ,PC6224P ,PC6248 , PC6224‬ו‪.PC6224F -‬‬ PowerConnect 6200 ‫‪PC 6224‬‬ 1-1‬‬ ‫‪PC 6248‬‬...
Release Notes - Page 3

... Applicable Version No. 3.2.0.6 Release Date May 2010 Firmware Upgrade NOTE: Version 3.2 includes improvements to update the boot code AND firmware. NOTE: The PC6200 switches when stacked require that this release note be installed on every switch member. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Introduction This document provides specific information for the Dell...
Release Notes - Page 4

...product software. NOTE: OMNM 4.1 will not discover the switches running any version of 3.x.y.z firmware therefore users should save their configuration file to a PowerConnect 62xx device that is not supported. Only use it ...product software. Hardware Supported PowerConnect 6224 PowerConnect 6248 PowerConnect 6224F PowerConnect 6224P PowerConnect 6248P 2 System Firmware Version 3.2.0.6
Release Notes - Page 5

...-channel trunk index. ¾ Configurable Message of the Day Banner The system supports a configurable message of the switch will allow the forwarding plane of a power failure, hardware failure, or software fault on the console. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Added Functionality in Power Connect Release 2.1 to accept a VLAN name as...
Release Notes - Page 7

... ARP packets. The MGMD Proxy is used to share information between neighboring devices (routers, bridges, access servers, and switches). PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ MLD Snooping (RFC2710) In IPv4, Layer 2 switches can use IGMP Snooping to limit the flooding of multicast traffic by dynamically configuring Layer 2 interfaces so that multicast...
Release Notes - Page 9

... though the physical network is useful when there are only two routers attached to the link (either a physical or virtual LAN). System Firmware Version 3.2.0.6 Page 7 PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ Ping/Traceroute Enhancements New ping options have been added to allow the user to specify the number and...
Release Notes - Page 11

... through tracking process. ¾ ICMP Throttling This adds configuration options for IPv6 Hosts and Routers, the IPv6 MTU on each interface. System Firmware Version 3.2.0.6 Page 9 PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ Configured Tunnels MTU To comply with DHCP server addresses specified independently on configured IPv6 over IPv4 tunnels was...
Release Notes - Page 13

... topology change notification. This feature is not forwarded (acting in the same manner as the blocking state). It is moved to a "loop-inconsistent blocking state." PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Changed Functionality in this link as loop free and begins transitioning the link from blocking to forwarding. In forwarding...
Release Notes - Page 15

... to 128. The ip multicast staticroute command is enabled by default. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ Trap Configuration In previous versions of the software, configuration of places. If your previous configuration had flow control disabled, you upgrade a switch to support long usernames. ¾ Flow Control Flow Control is deprecated...
Release Notes - Page 17

... mode Rationale: The rmon table-size log command has been deprecated. It has been replaced by the show ip dhcp filtering command has been deprecated. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Deprecated Commands and Parameters The following CLI commands have been deprecated: • delete-on-reset • delete-on-timeout...
Release Notes - Page 19

...determine how cutthrough mode is a list of updated time with Router Alert Option. The switch must be deleted for correcting log messages time. Asset-tag is understood correctly. Used ... set like other . Added the no form for snmp-server host CLI command. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Issues Resolved The following is configured via the show...
Release Notes - Page 21

...authenticate a client when radius server is not reported correctly. NIM_events prints unknown characters. Switch gives error message when entered upper case letter for the interface name. Custom Protocol-...not displayed properly. Web page affected Switching > VLAN > Protocol Group Table. 1. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Description Cannot enter Daylight Saving Time from ...
Release Notes - Page 25

... to delete the message, and disable the banner. Use 'no configuration should be required to acknowledge the banner displayed on that the switch waits before authorizing the client if the client is a dot1x unaware client. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes RADIUS Accounting Servers Title radius-server host acct Description The...
Release Notes - Page 27

... is getting loaded to avoid the restarting order. Banner MOTD: The switches Console and Web sessions are inaccessible until the user enters a response ...PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Known Issues Summary Non-configuration file getting read an invalid start-up configuration file, it will give up and create a default startup configuration. User Impact When the switch...
Release Notes - Page 31

.... User Impact The maximum number of MAC-based VLANs is a known limitation of the PowerConnect 6200 series switches. ip default gateway is for the management interface and ip default route is used for different types of interfaces. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes LACP Description LAGs Supported VLAN Description vlan association mac...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerConnect 6224 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.