Get support for Dell PowerConnect 6224

Dell PowerConnect 6224 Support Question

Dell PowerConnect 6224 Support Question

Find answers below for this question about Dell PowerConnect 6224.
Need a Dell PowerConnect 6224 manual? We have 5 online manuals for this item!
Question posted by Rinkasha on April 21st, 2014

How To Backup 6224 Switch

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Dell PowerConnect 6224 Manual Pages

Command Line Interface Guide - Page 1322

... Preference Code Version Description This field displays the index into the database of the switch type. This field indicates the management preference value of the show supported switchtype 1 Switch Type 0x73950001 Model Identifier 6224 Switch Description PowerConnect 6224 Management Preference 1 Expected Code Type 0x100b000 Supported Cards: Card Index (CID 3 Model Identifier PCM8024...
User's Guide - Page 19

...-Ethernet (PoE) capability. NOTE: Before proceeding, read the release notes for RJ-45 or SFP interfaces. The Dell PowerConnect 6224 switch supports 24 1000Base-T copper ports and 4 "combo" ports for this section include: • System Features • Switching Features • Routing Features • IPv6 • Quality of Service Features • Multicast Features • Additional...
User's Guide - Page 21

... Management Information Base (MIB) that allows event notifications to be sent to set of backup firmware images. Remote Monitoring (RMON) RMON is supported. Real Time Clock The Real ...SNTP, see "Managing Logs." Trivial File Transfer Protocol (TFTP) The PowerConnect 6200 Series switches support boot image, firmware, and configuration upload or download through TFTP. For more information...
User's Guide - Page 25

The PowerConnect 6200 Series enhances auto negotiation by occupying the link so that share a point-to-point link segment, and to automatically configure both switches to configure the port...with Crossover (MDIX). Auto-MDI/MDIX Support The switch supports auto-detection between two switches that it is unavailable for hubs and switches is the standard wiring for end stations, and...
User's Guide - Page 59

...PowerConnect 6224, 6248, and 6224F Rear Panel Dual 10G slots for XFP, CX4, or stacking modules Dual 10G slots for XFP, CX4, or 10Gbase-T modules. The right slot (Bay 2) can support a plug-in Dual 10GbE XFP module, a 10GBase-T module, or a CX4 module. PowerConnect...Rear Panel Each PowerConnect 6200 series switch provides an RS-232 maintenance port, on the rear of the switch. This serial ...
User's Guide - Page 62

... the stacking ports of the top switch and the switch directly below it. For non-PoE switches, you can verify operation by observing the LEDs. You can also attach a redundant DC power supply, such as the PowerConnect RPS-600. Stacking You can stack up to 12 PowerConnect 6224 and/or 6248 switches, supporting up to connect the...
User's Guide - Page 63

...PowerConnect 6200 Series Switches XG1 Port XG2 Port Unit 1 Unit 2 Unit 3 Unit 4 In Figure 4-13, the stack has the following physical connections between the switches: • Unit 1 and Unit 2 are connected through the XG1 ports on each switch... member as a single switch with the current configuration. Stacking Standby The stacking feature supports a "Standby" or backup unit that will assume ...
User's Guide - Page 77

...event log using XMODEM 5 - Activate Backup Image 12 - Items such as addresses, versions, and dates may differ for each switch. Change baud rate 3 - Restore configuration...delete config files) 11 - Operational Code Date: Tue May 26 14:12:20 2009 Configuring Dell PowerConnect 77 Boot Menu 3.2.0.1 Select an option. Select (1, 2):2 Boot Menu Version: 3.2.0.1 Options available 1 ...
User's Guide - Page 180

... some networks, the RADIUS server is the configuration of the backup servers with the same RADIUS Server Name, designate one or more configured authentication servers that allows the switch to use the primary server first, and if the primary... The Remote Authorization Dial-In User Service (RADIUS) client on the PowerConnect 6200 Series switch supports multiple, named RADIUS servers.
Getting Started Guide - Page 266

‫‪show stack-port counters show stack-port diag show switch‬‬ ‫‪show supported switchtype‬‬ LED‬‬ LED Dell Power Connect PC6248P ,PC6224P ,PC6248 , PC6224‬ו‪.PC6224F -‬‬ PowerConnect 6200 ‫‪PC 6224‬‬ 1-1‬‬ ‫‪PC 6248‬‬...
Release Notes - Page 3

... version of firmware be thoroughly reviewed prior to installing or upgrading of this procedure may result in the zip file to the firmware management system. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Introduction This document provides specific information for the Dell PowerConnect 6200 Series switches, firmware version 3.2.0.6.
Release Notes - Page 4

...backup location before performing this firmware. NOTE: OMNM 4.1 will not discover the switches running firmware version 2.x or earlier. Supported Firmware Functionality For more details regarding the functionalities listed, please refer to a PowerConnect... 4.2. Hardware Supported PowerConnect 6224 PowerConnect 6248 PowerConnect 6224F PowerConnect 6224P PowerConnect 6248P 2 System ...
Release Notes - Page 5

...as protocols for protocol-based VLANs. When the management unit fails, only the management switch needs to be restarted. ¾ Configuration of CX-4/Stacking Modules This feature will ...release only ARP, IP and IPX are supported. This feature is called non-stop forwarding. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Added Functionality in Power Connect Release 2.1 to accept a VLAN...
Release Notes - Page 7

.... The MGMD Proxy is used to share information between neighboring devices (routers, bridges, access servers, and switches). System Firmware Version 3.2.0.6 Page 5 PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ MLD Snooping (RFC2710) In IPv4, Layer 2 switches can use IGMP Snooping to limit the flooding of multicast traffic by dynamically configuring Layer 2 interfaces so...
Release Notes - Page 15

... server priority is automatically enabled. The ip multicast staticroute command is enabled by default. If your previous configuration had flow control disabled, you upgrade a switch to 256. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ Trap Configuration In previous versions of the software, configuration of the flags for backward compatibility. The legacy...
Release Notes - Page 19

...cannot be deleted for correcting log messages time. Added a comment to indicate when the switch is configured in the respective APIs. MLD Packets are different and used reverse to provide ... packets that the only IPv4 address is accepted by -hop option set on the DUT. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Issues Resolved The following is a list of issues resolved in...
Release Notes - Page 21

...configured, the system returns an error message. NIM_events prints unknown characters. Web page affected Switching > VLAN > Protocol Group Table. 1. Captive Portal user can be configured. Resolution In...not accepting valid range. Corrected the error handling for the interface name. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Description Cannot enter Daylight Saving Time from...
Release Notes - Page 25

..., the session is terminated and no banner motd' to the login prompt. System Firmware Version 3.2.0.6 Page 23 PowerConnect 6224/6224F/6224P/6248/6248P Release Notes RADIUS Accounting Servers Title radius-server host acct Description The switches do not support creating accounting server names with the same name although the CLI Reference Manual and...
Release Notes - Page 27

... the router down and other routers in all users keep backups of a LAG will not be prompted to get access...the dead internal timer. If the configuration is saved and the switch is reset, the configuration is pending, it cannot process the other...user is used as a means for file download failures. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Known Issues Summary Non-configuration...
Release Notes - Page 31

... is for the ports to become active with traffic running . User Impact The maximum number of MAC-based VLANs is a known limitation of the PowerConnect 6200 series switches. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes LACP Description LAGs Supported VLAN Description vlan association mac command limitations User Impact Number of LAGs supported: •...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerConnect 6224 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.