Get support for Compaq DL360 - ProLiant - Photon

Compaq DL360 Support Question

Compaq DL360 Support Question

Find answers below for this question about Compaq DL360 - ProLiant - Photon.
Need a Compaq DL360 manual? We have 68 online manuals for this item!
Question posted by irparac on July 10th, 2014

What Is The Bios Key For Compaq Proliant Dl360

The person who posted this question about this Compaq product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Compaq DL360 Manual Pages

ProLiant DL360 G2 Server High-Density Deployment - Page 6

...management choices well in a single rack. Refer to ensure efficient deployments. All discussions of power requirements for ProLiant DL360 G2 servers are based on the input power of 308 W for calculation purposes. This document uses the ... deploying a high concentration of servers in advance to the Compaq ProLiant DL360 G2 Server QuickSpecs for detailed specifications and options for the...
ProLiant DL360 G2 Server High-Density Deployment - Page 7

... Installation of vertical-mount PDU brackets and Y-cables Where to Find www.compaq.com/proliant Compaq ProLiant DL360 G2 QuickSpecs www.compaq.com/support/servers/ProLiantDL360 G2.html Compaq ProLiant DL360 G2 Setup and Installation Guide, P/N 233832-001 Compaq ProLiant DL360 G2 Maintenance and Service Guide, P/N 233831-001 Vertical-Mount PDU Brackets with High-Voltage Cables kit, P/N 166097...
ProLiant DL360 G2 Server High-Density Deployment - Page 22

... in telco racks. The telco rack kit includes replacement server rails designed to the Compaq ProLiant DL360 G2 Setup and Installation Guide for complete installation instructions. ProLiant DL360 G2 Server High-Density Deployment 22 Refer to fit on the ProLiant DL360 G2 server. The ProLiant DL360 G2 server design supports deployment in a telco rack. Telco Rack Solution Many data...
ProLiant DL360 G2 Server High-Density Deployment - Page 34

... G2 server comes standard with the optional sliding server rails on rack installation, refer to the Compaq ProLiant DL360 G2 Setup and Installation Guide and accompanying documentation for installation. ProLiant DL360 G2 Server High-Density Deployment 34 Installation Procedures Note: Take necessary precautions for fixed rack rail kits. Rack Preparation 3. Step 1 can be used...
ProLiant DL360 G2 Server High-Density Deployment - Page 36

... the cables to each server to secure the server to the PDU. Connect the cables to the Compaq ProLiant DL360 G2 Hardware Configuration and Installation Poster. For detailed instructions on installing standard rack rails, refer to the Compaq ProLiant DL360 G2 Server Setup and Installation Guide and to the console switchbox. 5. See the "Server Preparation" section...
ProLiant DL360 Generation 2 Server Maintenance and Service Guide - Page 42

... slot, ensure that the module key is fully inserted. • Memory can be expanded to match the notch on the DIMM slot. Be sure to a maximum of 4-GB of the same size. • Install DIMMs only in the sequential order starting with Error Correction Code (ECC). Compaq ProLiant DL360 Generation 2 Server Maintenance and Service...
ProLiant DL360 Generation 2 Server Maintenance and Service Guide - Page 44

... 1 Figure 2-29: Removing an SDRAM DIMM Reverse steps 1 through 5 to match the key slots on the module with the tabs on the memory slot. See "Removing the Server ...the module down the server. IMPORTANT: DIMMs must be of the same size. Compaq ProLiant DL360 Generation 2 Server Maintenance and Service Guide 2-33 COMPAQ CONFIDENTIAL Codename: Maisto Part Number: 233831-001 Last Saved On: 12/12/...
ProLiant DL360 Generation 2 Server Maintenance and Service Guide - Page 49

... external contacts, or dispose of BIOS settings will occur if the lithium battery is removed. Under normal use the public collection system, or return them for recycling or proper disposal, please use , battery life is risk of along with the spare designated for more information. 2-38 Compaq ProLiant DL360 Generation 2 Server Maintenance and Service...
ProLiant DL360 Generation 2 Server Maintenance and Service Guide - Page 51

... the PPM(s). See "Processor Power Module" in this chapter. 15. Locate the alignment keys and keyhole locations through on the system board. 1 5 6 2 7 8 3 9 4 Figure 2-35: Locating alignment keys and keyhole locations 2-40 Compaq ProLiant DL360 Generation 2 Server Maintenance and Service Guide COMPAQ CONFIDENTIAL Codename: Maisto Part Number: 233831-001 Last Saved On: 12/12/01 3:47...
ProLiant DL360 Generation 2 Server Maintenance and Service Guide - Page 52

... from all the alignment keys. 17. Reinstall the processors with integrated thermal pad when replacing processors. Compaq ProLiant DL360 Generation 2 Server Maintenance and Service Guide 2-41 COMPAQ CONFIDENTIAL Codename: Maisto Part...board toward the front of the system board upward and lift it off the alignment keys . 1 2 Figure 2-36: Removing the system board CAUTION: Always use new ...
ProLiant DL360 Generation 2 Server Maintenance and Service Guide - Page 56

... by pressing the F9 key during POST Run this utility from within: • Compaq Insight Manager XE • Compaq Survey Utility • OS-specific IML utilities ROM-Based Setup Utility (RBSU) RBSU configures the hardware installed in or connected to create support diskettes. Compaq ProLiant DL360 Generation 2 Server Maintenance and Service Guide 4-3 COMPAQ CONFIDENTIAL Codename: Maisto...
ProLiant DL360 Generation 2 Server Maintenance and Service Guide - Page 79

...panel removing 2-7 replacing 2-7 ADU, description 4-1 air baffle removing 2-22 replacing 2-22 alignment keys 2-41 ASR, description 4-1 B battery removing 2-39 replacing 2-39 blanks, SCSI hard drive... slot 1 2-20 removing from slot 2 2-21 Compaq ProLiant DL360 Generation 2 Server Maintenance and Service Guide Index-1 COMPAQ CONFIDENTIAL Codename: Maisto Part Number: 233831-001 Last Saved On: 12...
ProLiant DL360 Generation 2 Server Maintenance and Service Guide - Page 80

...override jumper 5-7 internal health LED, status combinations 5-16 J jumper, iLO security override 5-7 K keys, alignment 2-41 L LEDs diagnostic 5-14 front panel status 5-10 front unit identification switch 2-6...replacing 2-36 socket locations 2-34 Index-2 Compaq ProLiant DL360 Generation 2 Server Maintenance and Service Guide COMPAQ CONFIDENTIAL Codename: Maisto Part Number: 233831-001 Last Saved On: ...
Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide - Page 22

... ensuring maximum dependability and supportability. 1-10 Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide Server Configuration and Management Compaq offers an extensive set of features and ...Support The ProLiant DL360 G2 server has a 2-MB ROM that provide USB support of the firmware. ROMPaq Utility Flash ROM enables you to upgrade the firmware (BIOS) with administrator...
Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide - Page 54

...expansion socket. Use Figure 3-14 and Table 3-3 to adversely affect data integrity. 3-20 Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide The following table lists DIMM option kits. Remove ...are known to identify the correct DIMM sockets. 4. CAUTION: Use only Compaq DIMMs. DIMMs from other sources are properly grounded before beginning any installation procedure. To install...
Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide - Page 86

...not disable the power cord grounding plug. Power up the server and press the F9 key when prompted to be installed on the server. Select the operating system to enter ...WARNING: To reduce the risk of the power supply and some internal circuitry remain active. 4-14 Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide After the server has successfully powered up, begin the ...
Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide - Page 107

... is divided into a series of menu selections designed to enter the RBSU. 8-2 Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide ROM-Based Setup Utility RBSU performs a wide range of configuration activities including the following keys: To access RBSU, press the F9 key during power up for confirmation of the system. The utility does not...
Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide - Page 113

... restored to the "ROMPaq disaster recovery mode". Select one of the screen, press the F9 key to Redundant ROM Settings To access the redundant ROM: 1. Restart the server. 8-8 Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide Redundant ROM Support Compaq ProLiant DL360 G2 servers allow system ROM to exit the RBSU. 7. Select Redundant ROM. 4. If a corrupt...
Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide - Page 120

... ProLiant DL360 Generation 2 Server Setup and Installation Guide Compaq Insight Manager Compaq Insight Manager is displayed with buttons around its perimeter. 2. The selected server is a server management tool that have occurred, immediate action can be marked as repaired, which lowers the severity of all key server components. The selected server is Viewing the Event List...
Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide - Page 155

D-4 Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide Enabling ROMPaq Disaster Recovery Mode A corrupted system ROM will require recreation of the channel. Setting the NIC Operating Mode ProLiant DL360 G2 servers come standard with two Compaq NC7780 Gigabit 10/100/1000 Mbps network interface controllers (NICs). With a ProLiant DL360 G2 server, do not change SCSI device ...

Similar Questions

Proliant Dl 320 Do5?fo5 System Rom Bios Fan 4 Going Out
Help! We cannot access our server. It says 1611 Crital Fan Failure Detected Fan 4 System shutting do...
(Posted by adminstg 11 years ago)
How Do I Enter The Bios On My Dc7100 Desktop?
I want to change the boot order so that my computer boots first to a pendrive so taht I can boot and...
(Posted by qw21 11 years ago)
Need Manual For The Earlier Compaq Proliant Ml350 Server 2.
The Compaq Proliant ML350 server2 uses an intel pentium 3 processer and DDR 4 only
(Posted by eddiebower 12 years ago)
Compaq Proliant Ml350 G2 With Windows Server 2008
Dear, can we install windows server 2008 on Compaq ProLiant ML350 G2 (1.13MHz)?
(Posted by wisamshaban 13 years ago)
Ask a New Question
Use the box below to post a new question about this Compaq product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Compaq Manuals

Find free Compaq DL360 - ProLiant - Photon manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Compaq Reviews

View thousands of Compaq user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Compaq customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Compaq customer service rankings, employee comments and much more from our sister site.

Compaq Recalls

Find comprehensive Compaq recall information updated hourly on RecallOwl.com.