Use & Care Guide
Page 7
...to activate the EcoBoost™ option, which adds steam at the top of the load that is not adjustable. B EcoBoost™ Option Touch to manually reposition bulky loads midway through the cycle. C Static Reduce (on Heavy Duty, Normal, Bulky, Casual, Towels, and Delicates cycles. The light ...Towels, and Sanitize. Follow garment label instructions. This may adjust the Dryness Level on Automatic Cycles (except for your energy savings by using Manual Cycles, you are available on or off. To unlock the control, touch and hold Cycle Signal for available settings on the type of...
...to activate the EcoBoost™ option, which adds steam at the top of the load that is not adjustable. B EcoBoost™ Option Touch to manually reposition bulky loads midway through the cycle. C Static Reduce (on Heavy Duty, Normal, Bulky, Casual, Towels, and Delicates cycles. The light ...Towels, and Sanitize. Follow garment label instructions. This may adjust the Dryness Level on Automatic Cycles (except for your energy savings by using Manual Cycles, you are available on or off. To unlock the control, touch and hold Cycle Signal for available settings on the type of...
Use & Care Guide
Page 9
... Drying Temperature A High heat setting may select the "With Steam" setting to dry foam, Low rubber, plastic, or Extra Low heat-sensitive Air Only fabrics. MANUAL CYCLES Settings and options shown in your load. Not all features and cycles are available on each cycle. Do not add dryer sheets. † You...
... Drying Temperature A High heat setting may select the "With Steam" setting to dry foam, Low rubber, plastic, or Extra Low heat-sensitive Air Only fabrics. MANUAL CYCLES Settings and options shown in your load. Not all features and cycles are available on each cycle. Do not add dryer sheets. † You...
Use & Care Guide
Page 11
...in standby mode (power is running or paused. Touch DRYNESS LEVEL to scroll to save the new dryness level setting. 11 Manual Cycles: When you select a Manual Cycle, the default time appears in 1 minute increments. Changing the Automatic Cycle settings to reduce odors and light wrinkles in ... hold START/PAUSE to select the dryness level shown in dry loads consisting of periodic tumbling. If you have selected an Automatic Cycle, Manual Cycle, or Steam Cycle. You may adjust different settings, depending on all options and settings are displayed using the time display: 01 ...
...in standby mode (power is running or paused. Touch DRYNESS LEVEL to scroll to save the new dryness level setting. 11 Manual Cycles: When you select a Manual Cycle, the default time appears in 1 minute increments. Changing the Automatic Cycle settings to reduce odors and light wrinkles in ... hold START/PAUSE to select the dryness level shown in dry loads consisting of periodic tumbling. If you have selected an Automatic Cycle, Manual Cycle, or Steam Cycle. You may adjust different settings, depending on all options and settings are displayed using the time display: 01 ...
Use & Care Guide
Page 12
... drying rack cannot be used within that the selected cycle has ended and the load may be dried on top of energy used with the Manual Dry/ Timed Dry cycles only. Allow space around items for Automatic cycles only. Items containing foam, rubber, or plastic must be removed. See "Troubleshooting" ...FEATURES USING THE DRYING RACK To obtain a drying rack for use the drying rack, the drum continues to turn, but the drum will light when a Manual Cycle has been selected. The dryer will rate the energy use . When you do not hang over the edges or between items and the inside...
... drying rack cannot be used within that the selected cycle has ended and the load may be dried on top of energy used with the Manual Dry/ Timed Dry cycles only. Allow space around items for Automatic cycles only. Items containing foam, rubber, or plastic must be removed. See "Troubleshooting" ...FEATURES USING THE DRYING RACK To obtain a drying rack for use the drying rack, the drum continues to turn, but the drum will light when a Manual Cycle has been selected. The dryer will rate the energy use . When you do not hang over the edges or between items and the inside...
Installation Guide
Page 8
.... Gas supply pressure testing ■■The dryer must be an additional 18" (460 mm) from the floor. In Canada: An individual manual shut-off valve GAS SUPPLY CONNECTION REQUIREMENTS ■■Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the stainless steel ... of the dryer in accordance with the B149.1, Natural Gas and Propane Installation Code. DRYER GAS PIPE ■■The gas pipe that an individual manual shutoff valve be used . It is acceptable for opening and closing . D B A. 3/8" flexible gas connector B. 3/8" pipe to the dryer. See ...
.... Gas supply pressure testing ■■The dryer must be an additional 18" (460 mm) from the floor. In Canada: An individual manual shut-off valve GAS SUPPLY CONNECTION REQUIREMENTS ■■Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the stainless steel ... of the dryer in accordance with the B149.1, Natural Gas and Propane Installation Code. DRYER GAS PIPE ■■The gas pipe that an individual manual shutoff valve be used . It is acceptable for opening and closing . D B A. 3/8" flexible gas connector B. 3/8" pipe to the dryer. See ...