Ventilation Specification
Page 1
Post the following warning in the event the customer smells gas. This information should be obtained from your local gas supplier. W10100920D DRYER VENTING SPECIFICATIONS Table of Contents DRYER SAFETY...1 INSTALLATION REQUIREMENTS ...4 Venting Requirements ...5 DRYER INSPECTION AND CLEANING 7 Frequency of Exhaust System Cleaning 7 Inspecting the Exhaust System ...7 DRYER SAFETY ■ If you are installing a gas dryer, it is recommended that the owner post, in a prominent location, instructions for the customer's use in a prominent location.
Post the following warning in the event the customer smells gas. This information should be obtained from your local gas supplier. W10100920D DRYER VENTING SPECIFICATIONS Table of Contents DRYER SAFETY...1 INSTALLATION REQUIREMENTS ...4 Venting Requirements ...5 DRYER INSPECTION AND CLEANING 7 Frequency of Exhaust System Cleaning 7 Inspecting the Exhaust System ...7 DRYER SAFETY ■ If you are installing a gas dryer, it is recommended that the owner post, in a prominent location, instructions for the customer's use in a prominent location.
Ventilation Specification
Page 4
... avoid lint accumulation in cold weather. To remove excess heat from laundry area. 3. The dryer has 4" (102 mm) exhaust duct connections. WARNING: To reduce the risk of dryer vent systems. Whirlpool does not design multidryer vent systems, nor does Whirlpool review or provide approvals for vent systems designed by third-party engineering firms. Outside...
... avoid lint accumulation in cold weather. To remove excess heat from laundry area. 3. The dryer has 4" (102 mm) exhaust duct connections. WARNING: To reduce the risk of dryer vent systems. Whirlpool does not design multidryer vent systems, nor does Whirlpool review or provide approvals for vent systems designed by third-party engineering firms. Outside...
Ventilation Specification
Page 5
...range) to a residential-type 4" (102 mm) diameter rigid metal vent system. Codes Agency Approvals All Whirlpool electric dryer models, including "long vent dryers," Turbo Vent™ dryers and combo washer/dryer units that have an inlet and outlet for the minimum spacing allowed. ■ Additional spacing should be measured... the maximum rated vent length shown in the United States and Canada are UL listed (reference UL 2158 standard), and all Whirlpool gas dryer models are CSA listed (reference ANSI Z21.5.1 standard). See the following calculations may be reduced by 6 ft (1.83 m). ...
...range) to a residential-type 4" (102 mm) diameter rigid metal vent system. Codes Agency Approvals All Whirlpool electric dryer models, including "long vent dryers," Turbo Vent™ dryers and combo washer/dryer units that have an inlet and outlet for the minimum spacing allowed. ■ Additional spacing should be measured... the maximum rated vent length shown in the United States and Canada are UL listed (reference UL 2158 standard), and all Whirlpool gas dryer models are CSA listed (reference ANSI Z21.5.1 standard). See the following calculations may be reduced by 6 ft (1.83 m). ...
Ventilation Specification
Page 6
...and number of elbows for the type of the Use and Care Guide for an example of the maximum allowed. For single dryer venting systems, this code means that you are using. See the following illustration for details). Maximum back pressure measurement location B....blocked or partially blocked vent or that have airflow detection capabilities. (See specific model product literature for an example of three different multiple dryer venting systems. Option 1 - To resolve this case, the engineering firm that an architectural or HVAC engineering firm be considered. Barometric ...
...and number of elbows for the type of the Use and Care Guide for an example of the maximum allowed. For single dryer venting systems, this code means that you are using. See the following illustration for details). Maximum back pressure measurement location B....blocked or partially blocked vent or that have airflow detection capabilities. (See specific model product literature for an example of three different multiple dryer venting systems. Option 1 - To resolve this case, the engineering firm that an architectural or HVAC engineering firm be considered. Barometric ...
Ventilation Specification
Page 7
... the system and usage of these banks then exhausts into a central vertical vent. The frequency of the dryer. Complaints of long drying times or a hot dryer top indicate the need for an example of these inspections will not open or close completely. ■ After... hood (at several different levels. Each of a combination system. Central vertical duct - Maximum back pressure measurement location D. Weighted damper (each dryer) C. Option 3 - Combination System The combination system may collect in the exhaust hood so that the flappers or louvers will vary, depending ...
... the system and usage of these banks then exhausts into a central vertical vent. The frequency of the dryer. Complaints of long drying times or a hot dryer top indicate the need for an example of these inspections will not open or close completely. ■ After... hood (at several different levels. Each of a combination system. Central vertical duct - Maximum back pressure measurement location D. Weighted damper (each dryer) C. Option 3 - Combination System The combination system may collect in the exhaust hood so that the flappers or louvers will vary, depending ...
Installation Guide
Page 2
DRYER SAFETY IMPORTANT: When discarding or storing your old clothes dryer, remove the door. 2
DRYER SAFETY IMPORTANT: When discarding or storing your old clothes dryer, remove the door. 2
Installation Guide
Page 4
... the required tools and parts before purchasing parts. For further information, please refer to the "Assistance or Service" section in your dryer. See "Electrical Requirements" and "Venting Requirements" before starting installation. Optional Equipment: (Not supplied with riser Leveling legs (4) for ...your "Use and Care Guide." Read and follow the instructions provided with dryer) Check local codes. Check existing electrical supply and venting. Parts needed for gas installations: 8" (203 mm) or 10" (254 mm...
... the required tools and parts before purchasing parts. For further information, please refer to the "Assistance or Service" section in your dryer. See "Electrical Requirements" and "Venting Requirements" before starting installation. Optional Equipment: (Not supplied with riser Leveling legs (4) for ...your "Use and Care Guide." Read and follow the instructions provided with dryer) Check local codes. Check existing electrical supply and venting. Parts needed for gas installations: 8" (203 mm) or 10" (254 mm...
Installation Guide
Page 5
.... ■■ Steam models only: Cold water faucets located within 2 ft. (610 mm) of either side of 1" (25 mm) under entire dryer. this can be installed in an area where it will need: ■■ A location allowing for exhaust vent with maximum slope of...137.9-689.6 kPa). Models without riser Side view Bottom view: Back view NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for proper exhaust installation. LOCATION REQUIREMENTS INSTALLATION CLEARANCES The location must be exposed to open fully. If slope is greater than 1" (25 mm), clothes...
.... ■■ Steam models only: Cold water faucets located within 2 ft. (610 mm) of either side of 1" (25 mm) under entire dryer. this can be installed in an area where it will need: ■■ A location allowing for exhaust vent with maximum slope of...137.9-689.6 kPa). Models without riser Side view Bottom view: Back view NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for proper exhaust installation. LOCATION REQUIREMENTS INSTALLATION CLEARANCES The location must be exposed to open fully. If slope is greater than 1" (25 mm), clothes...
Installation Guide
Page 6
... result in "Assistance or Service" section of your "Use and Care Guide." ■■ Special provisions must be plugged into dryer. CANADA ONLY ELECTRICAL REQUIREMENTS Mobile home - A time-delay fuse or circuit breaker is recommended that the electrical connection is properly installed... and grounded in mobile homes to order. Do not modify the plug provided with the dryer: if it is recommended. Spacing for recessed area or closet installation All dimensions show recommended spacing allowed, with tested spacing of ...
... result in "Assistance or Service" section of your "Use and Care Guide." ■■ Special provisions must be plugged into dryer. CANADA ONLY ELECTRICAL REQUIREMENTS Mobile home - A time-delay fuse or circuit breaker is recommended that the electrical connection is properly installed... and grounded in mobile homes to order. Do not modify the plug provided with the dryer: if it is recommended. Spacing for recessed area or closet installation All dimensions show recommended spacing allowed, with tested spacing of ...
Installation Guide
Page 7
...well of your "Use and Care Guide." 7 WARNING: Improper connection of electric shock by a quali ed electrician. GAS DRYER POWER HOOKUP ELECTRICAL REQUIREMENTS WARNING GAS SUPPLY REQUIREMENTS Electrical Shock Hazard Plug into an appropriate outlet that a separate circuit serving only...this information does not agree with all local codes and ordinances. It is recommended. GROUNDING INSTRUCTIONS I For a grounded, cord-connected dryer: This dryer must have a proper outlet installed by providing a path of electric shock. In the event of malfunction or breakdown, grounding will ...
...well of your "Use and Care Guide." 7 WARNING: Improper connection of electric shock by a quali ed electrician. GAS DRYER POWER HOOKUP ELECTRICAL REQUIREMENTS WARNING GAS SUPPLY REQUIREMENTS Electrical Shock Hazard Plug into an appropriate outlet that a separate circuit serving only...this information does not agree with all local codes and ordinances. It is recommended. GROUNDING INSTRUCTIONS I For a grounded, cord-connected dryer: This dryer must have a proper outlet installed by providing a path of electric shock. In the event of malfunction or breakdown, grounding will ...
Installation Guide
Page 8
...ANSI Z21.24 or CSA 6.10. The location should use larger tubing and a different size adapter fitting. ■■ If your dryer has been converted to the gas supply line with a listed flexible gas connector that an individual manual shutoff valve be installed within six (6).... GAS SUPPLY CONNECTION REQUIREMENTS ■■ Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to flare adapter fitting C. 1/8" NPT minimum plugged tapping D. 1/2" NPT gas supply line E. No attempt shall be disconnected ...
...ANSI Z21.24 or CSA 6.10. The location should use larger tubing and a different size adapter fitting. ■■ If your dryer has been converted to the gas supply line with a listed flexible gas connector that an individual manual shutoff valve be installed within six (6).... GAS SUPPLY CONNECTION REQUIREMENTS ■■ Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to flare adapter fitting C. 1/8" NPT minimum plugged tapping D. 1/2" NPT gas supply line E. No attempt shall be disconnected ...
Installation Guide
Page 9
...of all connections by brushing on cardboard. Leave enough room for leveling legs To avoid damaging floor, use the cardboard corner posts the dryer was packed with to action of the riser. Do not use pipe-joint compound resistant to avoid damaging the back of cardboard from ...when handle is approximately 1/2" (13 mm) from gas pipe. Connect gas supply to connect the exhaust vent. Prepare dryer for electrical connection and to dryer 1. place under entire dryer. Screw in supply line; Foot is fully installed when bottom of foot is shown. Flared male fitting A Non-flared...
...of all connections by brushing on cardboard. Leave enough room for leveling legs To avoid damaging floor, use the cardboard corner posts the dryer was packed with to action of the riser. Do not use pipe-joint compound resistant to avoid damaging the back of cardboard from ...when handle is approximately 1/2" (13 mm) from gas pipe. Connect gas supply to connect the exhaust vent. Prepare dryer for electrical connection and to dryer 1. place under entire dryer. Screw in supply line; Foot is fully installed when bottom of foot is shown. Flared male fitting A Non-flared...
Installation Guide
Page 10
... Recommended for exhausting. 4" (102 mm) Angled Hood Elbows: ■■ 45° elbows provide better airflow than 90° elbows. Dryer exhaust must not be used . ■■ Do not use duct tape. IMPORTANT: Observe all joints. ■■ Exhaust vent must... vent: (Acceptable only if accessible to seal all governing codes and ordinances. For more information, see "Assistance or Service" section in final dryer location. ■■ Remove excess to achieve best drying performance. Recommended Styles: Good Better 4" (102 mm) heavy metal exhaust vent ...
... Recommended for exhausting. 4" (102 mm) Angled Hood Elbows: ■■ 45° elbows provide better airflow than 90° elbows. Dryer exhaust must not be used . ■■ Do not use duct tape. IMPORTANT: Observe all joints. ■■ Exhaust vent must... vent: (Acceptable only if accessible to seal all governing codes and ordinances. For more information, see "Assistance or Service" section in final dryer location. ■■ Remove excess to achieve best drying performance. Recommended Styles: Good Better 4" (102 mm) heavy metal exhaust vent ...
Installation Guide
Page 11
...your local dealer. ■■ Over-the-Top Installation: Part Number 4396028 ■■ Periscope Installation (For use with one offset elbow) B. B A A. Dryer B. Exhaust hood C D E F G B H E. Standard rear offset exhaust installation B. Optional exhaust installations: ■■ Exhaust Cover Kit (to the manufacturer...exhaust through the bottom. Select the type best for close clearance alternate installations are shown. If you prefer, dryer may be securely fastened to connect elbows H. Clamps F. Terminate exhaust vent outside. Wall D. PLAN VENT SYSTEM Recommended ...
...your local dealer. ■■ Over-the-Top Installation: Part Number 4396028 ■■ Periscope Installation (For use with one offset elbow) B. B A A. Dryer B. Exhaust hood C D E F G B H E. Standard rear offset exhaust installation B. Optional exhaust installations: ■■ Exhaust Cover Kit (to the manufacturer...exhaust through the bottom. Select the type best for close clearance alternate installations are shown. If you prefer, dryer may be securely fastened to connect elbows H. Clamps F. Terminate exhaust vent outside. Wall D. PLAN VENT SYSTEM Recommended ...
Installation Guide
Page 12
...(17.4 m) NOTE: Bottom exhaust installations have a 90° turn to use caulking compound to dryer location using elbows or making turns, allow as much room as possible. Whirlpool Vent System Chart Number of 90° elbows Type of vent Box/louvered hoods Angled hoods 0 ....7 m) 29 ft. (8.8 m) 4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m) Maytag Vent System Chart Number of 90° elbows Type of dryer. ■■ Reduce performance, resulting in the "Y" connector. Avoid 90° turns. Run vent to seal exterior wall opening around exhaust hood. 2. Install exhaust...
...(17.4 m) NOTE: Bottom exhaust installations have a 90° turn to use caulking compound to dryer location using elbows or making turns, allow as much room as possible. Whirlpool Vent System Chart Number of 90° elbows Type of vent Box/louvered hoods Angled hoods 0 ....7 m) 29 ft. (8.8 m) 4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m) Maytag Vent System Chart Number of 90° elbows Type of dryer. ■■ Reduce performance, resulting in the "Y" connector. Avoid 90° turns. Run vent to seal exterior wall opening around exhaust hood. 2. Install exhaust...
Installation Guide
Page 13
Attach long hose to the cold water faucet, the short hose must be used. If "Y" connector cannot be attached directly to dryer fill valve and tighten coupling Fig. Screw on coupling by hand until it is seated on connector. 3. Screw on coupling by hand until it is .... Using pliers, tighten the couplings an additional two-thirds turn . B If space permits, attach the female end of the "Y" connector to the male end of dryer back panel. Tighten couplings 11" (279 mm) Attach other side of the long hose has a wire mesh strainer inside the coupling. Damage to the coupling...
Attach long hose to the cold water faucet, the short hose must be used. If "Y" connector cannot be attached directly to dryer fill valve and tighten coupling Fig. Screw on coupling by hand until it is seated on connector. 3. Screw on coupling by hand until it is .... Using pliers, tighten the couplings an additional two-thirds turn . B If space permits, attach the female end of the "Y" connector to the male end of dryer back panel. Tighten couplings 11" (279 mm) Attach other side of the long hose has a wire mesh strainer inside the coupling. Damage to the coupling...
Installation Guide
Page 14
...system to exhaust hood with riser Models without riser If dryer is in dryer. Check that vent is clean. NOTE: The dryer must fit over dryer exhaust outlet and inside exhaust hood. Repeat from front to exhaust outlet LEVEL DRYER 1. Not Level LEVEL 2. After dryer is not level, prop up using a wood block..., use wrench to exhaust outlet in place, remove cardboard from side to final location. Move dryer to side. Once legs are snug against the floor. 14 Avoid crushing or kinking vent. If connecting to existing vent, make sure ...
...system to exhaust hood with riser Models without riser If dryer is in dryer. Check that vent is clean. NOTE: The dryer must fit over dryer exhaust outlet and inside exhaust hood. Repeat from front to exhaust outlet LEVEL DRYER 1. Not Level LEVEL 2. After dryer is not level, prop up using a wood block..., use wrench to exhaust outlet in place, remove cardboard from side to final location. Move dryer to side. Once legs are snug against the floor. 14 Avoid crushing or kinking vent. If connecting to existing vent, make sure ...
Installation Guide
Page 15
... work space to see what was skipped. Do not select Air Only Temperature setting. This odor is common when heating element is on dryer. Open the dryer door. 2. Remove the bottom screw (B) from each of a water softener is closed. Install 4 plastic plugs (A) into a grounded outlet. COMPLETE ...have all of your tools. All Models: q Select a Timed Dry heated cycle, and start of scale through steps to avoid damaging the surface. If dryer will not start, check the following: • Controls are now installed. A B A B 4. Over time, the buildup of lime scale may clog ...
... work space to see what was skipped. Do not select Air Only Temperature setting. This odor is common when heating element is on dryer. Open the dryer door. 2. Remove the bottom screw (B) from each of a water softener is closed. Install 4 plastic plugs (A) into a grounded outlet. COMPLETE ...have all of your tools. All Models: q Select a Timed Dry heated cycle, and start of scale through steps to avoid damaging the surface. If dryer will not start, check the following: • Controls are now installed. A B A B 4. Over time, the buildup of lime scale may clog ...
Installation Guide
Page 16
... side to attach the hinge to engage door strike. 16 A B A . Remove the 4 screws and two hinges from the opposite side of dryer door opening from the dryer door opening . Remove the door strike (A) from where they were removed. NOTE: Door strike and plugs must be on the opposite side of... the door. Do not tighten screws. Install two bottom screws. Align bottom screw holes in the same holes 3. Remove the 4 screws from the dryer door. 6. Hang door by placing screw heads into top slotted holes of screw exposed. Replace the 4 screws in hinge and door.
... side to attach the hinge to engage door strike. 16 A B A . Remove the 4 screws and two hinges from the opposite side of dryer door opening from the dryer door opening . Remove the door strike (A) from where they were removed. NOTE: Door strike and plugs must be on the opposite side of... the door. Do not tighten screws. Install two bottom screws. Align bottom screw holes in the same holes 3. Remove the 4 screws from the dryer door. 6. Hang door by placing screw heads into top slotted holes of screw exposed. Replace the 4 screws in hinge and door.