Owners Manual
Page 10
... fuel supply line. 5. Make sure leveling legs are secure in dryer base. 4. Moving Care For power supply cord-connected dryers: 1. Changing the drum light (on the back wall of the dryer. Plug into a grounded outlet or reconnect power. For gas dryers: 1. Unplug dryer or disconnect power. 2. (For gas dryers only): Close shut off power at home. Disconnect wiring...
... fuel supply line. 5. Make sure leveling legs are secure in dryer base. 4. Moving Care For power supply cord-connected dryers: 1. Changing the drum light (on the back wall of the dryer. Plug into a grounded outlet or reconnect power. For gas dryers: 1. Unplug dryer or disconnect power. 2. (For gas dryers only): Close shut off power at home. Disconnect wiring...
Owners Manual
Page 11
... door. Clothing knotted or balled up , the load will increase drying times. Separate the load items and restart the dryer. http://www.whirlpool.com/help - Use 4" (102 mm) diameter vent material. Electric dryers use it a gas dryer? Replace both fuses or reset the circuit breaker. The drum may be a thumping sound during the first few...
... door. Clothing knotted or balled up , the load will increase drying times. Separate the load items and restart the dryer. http://www.whirlpool.com/help - Use 4" (102 mm) diameter vent material. Electric dryers use it a gas dryer? Replace both fuses or reset the circuit breaker. The drum may be a thumping sound during the first few...
Dimension Guide
Page 1
...old hoses. Louvered hood 4" (102 mm) B. Large opening side-swing door B. Recessed area B. Do not use with Natural gas. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to the cold water faucet using new inlet ...- Use the fewest 90° turns possible. 29" and 27" Wide Model Gas Dryer PRODUCT MODEL NUMBERS WGD4750X, WGD4800X, WGD4900X, WGD5500X, WGD5550X, WGD5600X, WGD5700X, WGD4850X, WGD4890X, WGD5610X Gas supply: This dryer is equipped for use vent runs longer than specified in vent length chart. Angled ...
...old hoses. Louvered hood 4" (102 mm) B. Large opening side-swing door B. Recessed area B. Do not use with Natural gas. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to the cold water faucet using new inlet ...- Use the fewest 90° turns possible. 29" and 27" Wide Model Gas Dryer PRODUCT MODEL NUMBERS WGD4750X, WGD4800X, WGD4900X, WGD5500X, WGD5550X, WGD5600X, WGD5700X, WGD4850X, WGD4890X, WGD5610X Gas supply: This dryer is equipped for use vent runs longer than specified in vent length chart. Angled ...
Installation Instructions
Page 2
...that can kill or hurt you and others are not followed. The dryer must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1. This symbol alerts you to ...reduce the chance of others . DRYER SAFETY Your safety and the safety of injury, and tell you what...
...that can kill or hurt you and others are not followed. The dryer must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1. This symbol alerts you to ...reduce the chance of others . DRYER SAFETY Your safety and the safety of injury, and tell you what...
Installation Instructions
Page 4
... qualified or licensed by the State of Massachusetts. � If using a ball valve, it shall be a T-handle type. � A flexible gas connector, when used, must not exceed 3 feet. Tools needed for all installations: Adjustable wrench that opens to 1" (25 mm) or hex-head ... clamps 8" or 10" pipe wrench 8" or 10" adjustable wrench (for gas connections) Level 4 Pliers Pipe-joint compound resistant to LP gas IMPORTANT SAFETY INSTRUCTIONS When discarding or storing your old clothes dryer, remove the door. SAVE THESE INSTRUCTIONS INSTALLATION REQUIREMENTS Tools and Parts Gather the...
... qualified or licensed by the State of Massachusetts. � If using a ball valve, it shall be a T-handle type. � A flexible gas connector, when used, must not exceed 3 feet. Tools needed for all installations: Adjustable wrench that opens to 1" (25 mm) or hex-head ... clamps 8" or 10" pipe wrench 8" or 10" adjustable wrench (for gas connections) Level 4 Pliers Pipe-joint compound resistant to LP gas IMPORTANT SAFETY INSTRUCTIONS When discarding or storing your old clothes dryer, remove the door. SAVE THESE INSTRUCTIONS INSTALLATION REQUIREMENTS Tools and Parts Gather the...
Installation Instructions
Page 5
...sleeping quarters. Check code requirements. At lower temperatures, the dryer might not shut off at temperatures below 45°F (7°C). Contact your Use and Care Guide for information about accessories available for gas dryers. 5 Location Requirements You will be extended. Drying times can... be considered. ■■ Level floor with dryer) Refer to your local building inspector. Check that all parts are ...
...sleeping quarters. Check code requirements. At lower temperatures, the dryer might not shut off at temperatures below 45°F (7°C). Contact your Use and Care Guide for information about accessories available for gas dryers. 5 Location Requirements You will be extended. Drying times can... be considered. ■■ Level floor with dryer) Refer to your local building inspector. Check that all parts are ...
Installation Instructions
Page 8
... to reach for the type of the "Dryer User Instructions." Securely tighten all gas connections. Gas shutoff valve Gas supply connection requirements There are some guidelines for use Gas dryers must conform with local codes, or in accordance with the National Fuel Gas Code, ANSI Z223.1. Now stand the dryer on the model/serial rating plate for two...
... to reach for the type of the "Dryer User Instructions." Securely tighten all gas connections. Gas shutoff valve Gas supply connection requirements There are some guidelines for use Gas dryers must conform with local codes, or in accordance with the National Fuel Gas Code, ANSI Z223.1. Now stand the dryer on the model/serial rating plate for two...
Installation Instructions
Page 9
...up to prevent kinking. rating shown on the model/serial number plate. Do not remove ground prong. Failure to the rigid gas supply line. This dryer is more than 1/2 psi. Do not modify the plug provided with all local codes and ordinances. Do not use an ... ft. (6.1 m) can be provided. Burner input adjustments are using Natural Gas, do not use copper tubing. ■■ 3/8" flare x 3/8" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe, as to use LP gas, 3/8" LP compatible copper tubing can use TEFLON®† tape. Use...
...up to prevent kinking. rating shown on the model/serial number plate. Do not remove ground prong. Failure to the rigid gas supply line. This dryer is more than 1/2 psi. Do not modify the plug provided with all local codes and ordinances. Do not use an ... ft. (6.1 m) can be provided. Burner input adjustments are using Natural Gas, do not use copper tubing. ■■ 3/8" flare x 3/8" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe, as to use LP gas, 3/8" LP compatible copper tubing can use TEFLON®† tape. Use...
Installation Instructions
Page 10
... lint from ground or any object that may result in reduced airflow and poor performance. ■■ Do not install in final dryer location. ■■ Remove excess to avoid crushing and kinking. Review Vent system chart and if necessary, modify existing vent system to..., wallpaper, carpets, etc. Housecleaning problems and health problems. See "Venting Kits" for best drying performance and to avoid sagging and kinking that extend into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of duct and catch lint. B 4" C A (102 mm) Fire Hazard Use ...
... lint from ground or any object that may result in reduced airflow and poor performance. ■■ Do not install in final dryer location. ■■ Remove excess to avoid crushing and kinking. Review Vent system chart and if necessary, modify existing vent system to..., wallpaper, carpets, etc. Housecleaning problems and health problems. See "Venting Kits" for best drying performance and to avoid sagging and kinking that extend into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of duct and catch lint. B 4" C A (102 mm) Fire Hazard Use ...
Installation Instructions
Page 13
...) clamp. If connecting to exhaust outlet Flared male fitting Non-flared male fitting Remove red cap from under the dryer. 13 Your connection may be different, according to gas pipe. Open shut-off valve in supply line; valve is open when handle is parallel to supply line type,...to final location. Connect Vent 1. A recommended connection is used, be used to connect dryer to existing gas line. Avoid crushing or kinking vent. Dryer vent must be sure there are no kinks. After dryer is a registered trademark of vent to exhaust outlet in place, remove corner posts and ...
...) clamp. If connecting to exhaust outlet Flared male fitting Non-flared male fitting Remove red cap from under the dryer. 13 Your connection may be different, according to gas pipe. Open shut-off valve in supply line; valve is open when handle is parallel to supply line type,...to final location. Connect Vent 1. A recommended connection is used, be used to connect dryer to existing gas line. Avoid crushing or kinking vent. Dryer vent must be sure there are no kinks. After dryer is a registered trademark of vent to exhaust outlet in place, remove corner posts and ...
Installation Instructions
Page 14
...and Care Guide. Once legs are snug against the ground before tightening them. NOTE: The dryer must be level for 5 minutes, open it, then repeat the 5-minute test as outlined above. ■■ If the gas supply line shutoff valve is the 27" Wide Side-Swing Door, follow steps 1-13. ... up using a wood block, use wrench to see whether gas supply line shutoff valve is open. ■■ If the gas supply line shutoff valve is closed . q When the dryer has been running for the moisture sensing system to back. q Read "Dryer Use" in your door is the 29" Super Wide Side...
...and Care Guide. Once legs are snug against the ground before tightening them. NOTE: The dryer must be level for 5 minutes, open it, then repeat the 5-minute test as outlined above. ■■ If the gas supply line shutoff valve is the 27" Wide Side-Swing Door, follow steps 1-13. ... up using a wood block, use wrench to see whether gas supply line shutoff valve is open. ■■ If the gas supply line shutoff valve is closed . q When the dryer has been running for the moisture sensing system to back. q Read "Dryer Use" in your door is the 29" Super Wide Side...