Use & Care Guide
Page 4
... pedestals raise the washer and dryer to be installed on options and ordering, call 1-800-807-6777 or visit us at a premium, the stack kit allows the dryer to a more information on top of the washer. 4 Stack Kit If space is at : www.whirlpool.com/accessories. For more comfortable working and storage...
... pedestals raise the washer and dryer to be installed on options and ordering, call 1-800-807-6777 or visit us at a premium, the stack kit allows the dryer to a more information on top of the washer. 4 Stack Kit If space is at : www.whirlpool.com/accessories. For more comfortable working and storage...
Use & Care Guide
Page 5
... warranty and will reduce your drying times and improve your dryer for better fabric care and energy savings Use the Auto Cycles to follow the "Installation Instructions" supplied with Steam Cycles. n It is complete, be paid by : n Cleaning your steam dryer (on some models) n Results may ...not recommended with your energy savings. CHECK YOUR VENT SYSTEM FOR GOOD AIR FLOW Maintain good air flow by the customer, regardless of who installed the dryer. n Remove lint from clothes that have been starched. n Use the shortest length of time set and sometimes results in the...
... warranty and will reduce your drying times and improve your dryer for better fabric care and energy savings Use the Auto Cycles to follow the "Installation Instructions" supplied with Steam Cycles. n It is complete, be paid by : n Cleaning your steam dryer (on some models) n Results may ...not recommended with your energy savings. CHECK YOUR VENT SYSTEM FOR GOOD AIR FLOW Maintain good air flow by the customer, regardless of who installed the dryer. n Remove lint from clothes that have been starched. n Use the shortest length of time set and sometimes results in the...
Use & Care Guide
Page 11
.... Auto Cycles: You can be unable to remove the load promptly, select the Wrinkle Shield option before pressing START/PAUSE to add up to different installations, environmental conditions or personal preference. Promptly remove garments after cycle is retained and will be adjusted to adapt to 90 minutes of periodic tumbling after...
.... Auto Cycles: You can be unable to remove the load promptly, select the Wrinkle Shield option before pressing START/PAUSE to add up to different installations, environmental conditions or personal preference. Promptly remove garments after cycle is retained and will be adjusted to adapt to 90 minutes of periodic tumbling after...
Use & Care Guide
Page 13
...screen in dryer base. 6. Transport hose separately. 7. For direct-wired dryers: 1. Make sure leveling legs are at home. Reinstalling the Dryer Follow the "Installation Instructions" to remove lint. To clean: 1. Roll lint off the water supply to a residue buildup. Do not rinse or wash screen to locate, .... Wet lint is hard to remove residue buildup. 4. Roll lint off the screen into place. NON-USE, STORAGE, AND MOVING CARE Install and store your dryer. Gas models only: Cap the open fuel supply line. 5. CLEANING THE LINT SCREEN Every load cleaning The lint ...
...screen in dryer base. 6. Transport hose separately. 7. For direct-wired dryers: 1. Make sure leveling legs are at home. Reinstalling the Dryer Follow the "Installation Instructions" to remove lint. To clean: 1. Roll lint off the water supply to a residue buildup. Do not rinse or wash screen to locate, .... Wet lint is hard to remove residue buildup. 4. Roll lint off the screen into place. NON-USE, STORAGE, AND MOVING CARE Install and store your dryer. Gas models only: Cap the open fuel supply line. 5. CLEANING THE LINT SCREEN Every load cleaning The lint ...
Use & Care Guide
Page 14
... power as described in the lower right corner of the cover. Unplug dryer or disconnect power. 2. Turn bulb counterclockwise. Remove the screw located in the "Installation Instructions." SPECIAL INSTRUCTIONS FOR STEAM MODELS Water Inlet Hose Replace inlet hose and hose screen after 5 years of use to faucet. Open the dryer door...
... power as described in the lower right corner of the cover. Unplug dryer or disconnect power. 2. Turn bulb counterclockwise. Remove the screw located in the "Installation Instructions." SPECIAL INSTRUCTIONS FOR STEAM MODELS Water Inlet Hose Replace inlet hose and hose screen after 5 years of use to faucet. Open the dryer door...
Use & Care Guide
Page 15
...dryer drum. Dryer isn't properly leveled. Clothing is running. Clicking noise Gas valve operating. Check with a qualified electrician. See the "Installation Instructions." All four dryer feet should diminish after a few minutes of lint or replace exhaust vent with the floor. Clean lint screen..., make sure that both circuit breakers have heat. TROUBLESHOOTING First try the solutions suggested here or visit our website at www.whirlpool.com/help for assistance and to possibly avoid a service call an electrician. Replace the fuses or reset the circuit breaker. ...
...dryer drum. Dryer isn't properly leveled. Clothing is running. Clicking noise Gas valve operating. Check with a qualified electrician. See the "Installation Instructions." All four dryer feet should diminish after a few minutes of lint or replace exhaust vent with the floor. Clean lint screen..., make sure that both circuit breakers have heat. TROUBLESHOOTING First try the solutions suggested here or visit our website at www.whirlpool.com/help for assistance and to possibly avoid a service call an electrician. Replace the fuses or reset the circuit breaker. ...
Use & Care Guide
Page 16
...Level the dryer. Increasing or decreasing the dryness level will not transfer to tumble freely. Add dryer sheets at www.whirlpool.com/help for most installations, the rear of garments (1-9). Dry clean only garments are consistently ending too early, see also "Changing the Auto... here or visit our website at the beginning of the cycle. The load may experience underdrying. Under certain environmental or installation conditions you experience Possible Causes Solution Dryer Results (cont.) Clothes are not drying satisfactorily or drying times are wrinkled The load...
...Level the dryer. Increasing or decreasing the dryness level will not transfer to tumble freely. Add dryer sheets at www.whirlpool.com/help for most installations, the rear of garments (1-9). Dry clean only garments are consistently ending too early, see also "Changing the Auto... here or visit our website at the beginning of the cycle. The load may experience underdrying. Under certain environmental or installation conditions you experience Possible Causes Solution Dryer Results (cont.) Clothes are not drying satisfactorily or drying times are wrinkled The load...
Use & Care Guide
Page 17
...whirlpool.com/help for assistance and to avoid overdrying the load. Odors are gone from the area, rewash and dry the clothing. Using a cycle with heat, and restart the dryer. Select an Auto Cycle with a lower heat setting to possibly avoid a service call. the vent is properly installed... Displaying Code Message "PF" (power failure) The drying cycle has been interrupted by a power failure. Try the following : Check to "Installation Instructions" for the type of cycle complete. For steam cycles, the water is clogged; This cycle is free of wrinkle-free cotton, cotton...
...whirlpool.com/help for assistance and to avoid overdrying the load. Odors are gone from the area, rewash and dry the clothing. Using a cycle with heat, and restart the dryer. Select an Auto Cycle with a lower heat setting to possibly avoid a service call. the vent is properly installed... Displaying Code Message "PF" (power failure) The drying cycle has been interrupted by a power failure. Try the following : Check to "Installation Instructions" for the type of cycle complete. For steam cycles, the water is clogged; This cycle is free of wrinkle-free cotton, cotton...
Use & Care Guide
Page 18
... WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with Whirlpool's published installation instructions. 10. Proof of your major appliance to obtain service under this information on the model and serial number label located on major appliances...
... WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with Whirlpool's published installation instructions. 10. Proof of your major appliance to obtain service under this information on the model and serial number label located on major appliances...
Installation Guide
Page 1
...Connection 11 VENTING 14 Venting Requirements 14 Plan Vent System 15 Venting Kits 15 Install Vent System 16 CONNECT INLET HOSE 17 CONNECT VENT 18 LEVEL DRYER 19 COMPLETE INSTALLATION CHECKLIST 19 DOOR REVERSAL KIT (OPTIONAL 20 STACKING WASHER AND DRYER (OPTIONAL 20... TROUBLESHOOTING 20 Para una version de estas instrucciones en español, visite www.Whirlpool.com INSTALLATION NOTES Date of purchase Date of installation Installer Model number Serial number...
...Connection 11 VENTING 14 Venting Requirements 14 Plan Vent System 15 Venting Kits 15 Install Vent System 16 CONNECT INLET HOSE 17 CONNECT VENT 18 LEVEL DRYER 19 COMPLETE INSTALLATION CHECKLIST 19 DOOR REVERSAL KIT (OPTIONAL 20 STACKING WASHER AND DRYER (OPTIONAL 20... TROUBLESHOOTING 20 Para una version de estas instrucciones en español, visite www.Whirlpool.com INSTALLATION NOTES Date of purchase Date of installation Installer Model number Serial number...
Installation Guide
Page 3
...Refer to the dryer must end in your dryer. 3 Tools needed: Flat-blade screwdriver #2 Phillips screwdriver Wire stripper (direct wire installations) Tin snips (new vent installations) Parts needed: (Not supplied with a pedestal or a stack kit. The kit should be type SRD or SRDT and be ...ring terminals or spade terminals with clothes dryers. If using a power supply cord: Use a UL listed power supply cord kit marked for your installation. NOTE: Do not use with upturned ends. ■■A UL listed strain relief. 1/4" and 5/16" nut driver (recommended) Adjustable wrench...
...Refer to the dryer must end in your dryer. 3 Tools needed: Flat-blade screwdriver #2 Phillips screwdriver Wire stripper (direct wire installations) Tin snips (new vent installations) Parts needed: (Not supplied with a pedestal or a stack kit. The kit should be type SRD or SRDT and be ...ring terminals or spade terminals with clothes dryers. If using a power supply cord: Use a UL listed power supply cord kit marked for your installation. NOTE: Do not use with upturned ends. ■■A UL listed strain relief. 1/4" and 5/16" nut driver (recommended) Adjustable wrench...
Installation Guide
Page 4
... (89 mm) Water Inlet: 31/4" (83 mm) 1"* (25 mm) * Approx. Check code requirements. Some codes limit, or do not permit, installing dryer in door are provided. ■■Level floor with elbow. Contact your local building inspector. 1"* (25 mm) * Approx. See "Venting Requirements." 4...dryer not to water and/or weather. measurement 14" (358 mm) 61/8" (156 mm) † Steam models only NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for ease of dryer. LOCATION REQUIREMENTS Check code requirements. DRYER DIMENSIONS Front view: ...
... (89 mm) Water Inlet: 31/4" (83 mm) 1"* (25 mm) * Approx. Check code requirements. Some codes limit, or do not permit, installing dryer in door are provided. ■■Level floor with elbow. Contact your local building inspector. 1"* (25 mm) * Approx. See "Venting Requirements." 4...dryer not to water and/or weather. measurement 14" (358 mm) 61/8" (156 mm) † Steam models only NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for ease of dryer. LOCATION REQUIREMENTS Check code requirements. DRYER DIMENSIONS Front view: ...
Installation Guide
Page 5
...HUD Part 280) or Standard CAN/CSA-Z240 MH. For further information, see "Assistance or Service" section in your dealer. Mobile home installations require: ■■Metal exhaust system hardware, available for purchase from your Use and Care Guide. ■■Special provisions must conform ...Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for mobile home installations. Recommended installation clearances: Closet installation (dryer only): 34" recommended (864 mm) 18" min. (457 mm) 3" (76 mm) 48 in.2 (310 cm2) Cabinet...
...HUD Part 280) or Standard CAN/CSA-Z240 MH. For further information, see "Assistance or Service" section in your dealer. Mobile home installations require: ■■Metal exhaust system hardware, available for purchase from your Use and Care Guide. ■■Special provisions must conform ...Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for mobile home installations. Recommended installation clearances: Closet installation (dryer only): 34" recommended (864 mm) 18" min. (457 mm) 3" (76 mm) 48 in.2 (310 cm2) Cabinet...
Installation Guide
Page 6
...National Electrical Code requires a 4-wire power supply connection for it is recommended that a qualified electrician determine that the ground path is installed with a 3-wire electrical supply connection. The 3-wire power supply cord, at least 5 ft. (1.52 m) long. ■■...1996, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral is manufactured ready to install with a 4-wire electrical supply connection, the neutral ground conductor must be removed from : National Fire Protection Association, One Batterymarch Park...
...National Electrical Code requires a 4-wire power supply connection for it is recommended that a qualified electrician determine that the ground path is installed with a 3-wire electrical supply connection. The 3-wire power supply cord, at least 5 ft. (1.52 m) long. ■■...1996, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral is manufactured ready to install with a 4-wire electrical supply connection, the neutral ground conductor must be removed from : National Fire Protection Association, One Batterymarch Park...
Installation Guide
Page 7
... legs until it is no longer visible. Place a carton corner post from dryer carton; Stand the dryer up. Leave enough room to its final location. INSTALL LEVELING LEGS 1. Slide the dryer on cardboard. 2. Firmly grasp dryer body (not console panel) and gently lay dryer down on the corner posts until diamond...
... legs until it is no longer visible. Place a carton corner post from dryer carton; Stand the dryer up. Leave enough room to its final location. INSTALL LEVELING LEGS 1. Slide the dryer on cardboard. 2. Firmly grasp dryer body (not console panel) and gently lay dryer down on the corner posts until diamond...
Installation Guide
Page 8
... connection. Remove terminal block cover 4-wire direct connection: Go to Direct Wire Connection. 3-wire direct connection: Go to "Optional 3-wire connection". ELECTRIC INSTALLATION For power supply cord installations: For direct wire installations: Before you start: disconnect power. 1. Remove hold-down screw and terminal block cover. 8 Power supply cord 3-wire receptacle (NEMA Type 10...
... connection. Remove terminal block cover 4-wire direct connection: Go to Direct Wire Connection. 3-wire direct connection: Go to "Optional 3-wire connection". ELECTRIC INSTALLATION For power supply cord installations: For direct wire installations: Before you start: disconnect power. 1. Remove hold-down screw and terminal block cover. 8 Power supply cord 3-wire receptacle (NEMA Type 10...
Installation Guide
Page 13
... under center, terminal block screw (B). Connect remaining wires E B Place ends of power supply cord or cable under outer terminal block screws. Connect external ground wire Install the correct strain relief for 3-Wire Connection (Power Supply Cord Shown) IMPORTANT: You must verify with hold -down screw. Secure cover with a qualified electrician that...
... under center, terminal block screw (B). Connect remaining wires E B Place ends of power supply cord or cable under outer terminal block screws. Connect external ground wire Install the correct strain relief for 3-Wire Connection (Power Supply Cord Shown) IMPORTANT: You must verify with hold -down screw. Secure cover with a qualified electrician that...
Installation Guide
Page 14
... must not be connected or secured with screws or other fastening devices that may result in reduced airflow and poor performance. ■■ Do not install in enclosed walls, ceilings, or floors. ■■ The total length should cap the vent to avoid sagging and kinking that may obstruct exhaust (such...
... must not be connected or secured with screws or other fastening devices that may result in reduced airflow and poor performance. ■■ Do not install in enclosed walls, ceilings, or floors. ■■ The total length should cap the vent to avoid sagging and kinking that may obstruct exhaust (such...
Installation Guide
Page 15
... the mobile home. If you prefer, dryer may be securely fastened to connect elbows H. Exhaust hood E. Exhaust outlet Optional exhaust installations: Over-the-top installation (also available with one offset elbow) Periscope installation Special provisions for close clearance): C D E A. Plan Vent System Choose your local dealer to exhaust out right side, left side, or...
... the mobile home. If you prefer, dryer may be securely fastened to connect elbows H. Exhaust hood E. Exhaust outlet Optional exhaust installations: Over-the-top installation (also available with one offset elbow) Periscope installation Special provisions for close clearance): C D E A. Plan Vent System Choose your local dealer to exhaust out right side, left side, or...
Installation Guide
Page 16
... exterior wall opening around exhaust hood. 2. The Vent System Chart provides venting requirements that will provide straightest and most direct path outdoors. ■■Plan installation to use fewest number of vent Box/louvered hoods Angled hoods 0 Rigid metal 64 ft. (20 m) 58 ft. (17.7 m) 1 Rigid metal ... they can catch lint. 16 To determine maximum exhaust length, add one 90° turn inside the dryer. NOTE: Do not use . Install Vent System 1. Run vent to exhaust hood with 4" (102 mm) clamp. Determine vent path: ■■Select route that will help achieve...
... exterior wall opening around exhaust hood. 2. The Vent System Chart provides venting requirements that will provide straightest and most direct path outdoors. ■■Plan installation to use fewest number of vent Box/louvered hoods Angled hoods 0 Rigid metal 64 ft. (20 m) 58 ft. (17.7 m) 1 Rigid metal ... they can catch lint. 16 To determine maximum exhaust length, add one 90° turn inside the dryer. NOTE: Do not use . Install Vent System 1. Run vent to exhaust hood with 4" (102 mm) clamp. Determine vent path: ■■Select route that will help achieve...