Ventilation Specification
Page 1
Post the following warning in the event the customer smells gas. DRYER VENTING SPECIFICATIONS Table of Contents DRYER SAFETY...1 INSTALLATION REQUIREMENTS ...4 Venting Requirements ...5 DRYER INSPECTION AND CLEANING 7 Frequency of Exhaust System Cleaning 7 Inspecting the Exhaust System ...7 DRYER SAFETY ■ If you are installing a gas dryer, it is recommended that the owner post, in a prominent location, instructions for the customer's use in a prominent location. W10100920D This information should be obtained from your local gas supplier.
Post the following warning in the event the customer smells gas. DRYER VENTING SPECIFICATIONS Table of Contents DRYER SAFETY...1 INSTALLATION REQUIREMENTS ...4 Venting Requirements ...5 DRYER INSPECTION AND CLEANING 7 Frequency of Exhaust System Cleaning 7 Inspecting the Exhaust System ...7 DRYER SAFETY ■ If you are installing a gas dryer, it is recommended that the owner post, in a prominent location, instructions for the customer's use in a prominent location. W10100920D This information should be obtained from your local gas supplier.
Ventilation Specification
Page 4
...when measured at one time. ■ Consider moisture, lint and air temperature in the design of dryer vent systems. Whirlpool does not design multidryer vent systems, nor does Whirlpool review or provide approvals for vent systems designed by third-party engineering firms. Outside Exhaust The four ... is intended to aid licensed HVAC or Architectural Engineers who design single and multi-dryer unit venting systems for Whirlpool Corporation dryers sold in the dryer, heat is not exhausted outside, this dryer MUST BE EXHAUSTED OUTDOORS. To avoid lint accumulation in the laundry area. See ...
...when measured at one time. ■ Consider moisture, lint and air temperature in the design of dryer vent systems. Whirlpool does not design multidryer vent systems, nor does Whirlpool review or provide approvals for vent systems designed by third-party engineering firms. Outside Exhaust The four ... is intended to aid licensed HVAC or Architectural Engineers who design single and multi-dryer unit venting systems for Whirlpool Corporation dryers sold in the dryer, heat is not exhausted outside, this dryer MUST BE EXHAUSTED OUTDOORS. To avoid lint accumulation in the laundry area. See ...
Ventilation Specification
Page 5
... confined area B. A. Location on Air Only cycle B. 12" (305 mm) min. Codes Agency Approvals All Whirlpool electric dryer models, including "long vent dryers," Turbo Vent™ dryers and combo washer/dryer units that are sold in the United States and Canada are UL listed (reference UL 2158 standard), and all sides... as the door, provided it will not be required for wall, door, and floor moldings. ■ Additional spacing of 1" (25 mm) on all Whirlpool gas dryer models are defined as Dwyer model 102 (0"-2" [0 mm - 51 mm] range) or Dwyer model 172 (0"-1" [0 mm - 25 mm] range) to ...
... confined area B. A. Location on Air Only cycle B. 12" (305 mm) min. Codes Agency Approvals All Whirlpool electric dryer models, including "long vent dryers," Turbo Vent™ dryers and combo washer/dryer units that are sold in the United States and Canada are UL listed (reference UL 2158 standard), and all sides... as the door, provided it will not be required for wall, door, and floor moldings. ■ Additional spacing of 1" (25 mm) on all Whirlpool gas dryer models are defined as Dwyer model 102 (0"-2" [0 mm - 51 mm] range) or Dwyer model 172 (0"-1" [0 mm - 25 mm] range) to ...
Ventilation Specification
Page 6
...firm that your entire home venting run length and number of elbows for each floor D. 0.1" (2.5 mm) water column maximum vacuum E. For multi-dryer venting systems, the "AF" code means that your overall vent system length is free of lint and debris. ■ Confirm that designed the system..., an "AF" code will be displayed on each application. A. If the airflow in .2 * (310 cm2) 3"* (76 mm) Multiple Dryer Venting Systems Multiple dryer venting systems must be designed specifically for the type of vent you may be consulted for recessed or closet installation, with stacked washer and...
...firm that your entire home venting run length and number of elbows for each floor D. 0.1" (2.5 mm) water column maximum vacuum E. For multi-dryer venting systems, the "AF" code means that your overall vent system length is free of lint and debris. ■ Confirm that designed the system..., an "AF" code will be displayed on each application. A. If the airflow in .2 * (310 cm2) 3"* (76 mm) Multiple Dryer Venting Systems Multiple dryer venting systems must be designed specifically for the type of vent you may be consulted for recessed or closet installation, with stacked washer and...
Ventilation Specification
Page 7
... for inspection of Exhaust System Cleaning Every exhaust system must be used in multiple dryer systems, a more frequent inspection is intact and free from the exhaust hood. Weighted damper (each dryer) C. Operate the dryer and verify that the exhaust air is not obstructed in the vent and that ...in the system. ■ Seal any lint accumulation. ■ Be sure that it is recommended. A B C E D A. Central vertical duct - Outside air source DRYER INSPECTION AND CLEANING Frequency of the exhaust system. In commercial usage or in high-rise apartments, with a bank of...
... for inspection of Exhaust System Cleaning Every exhaust system must be used in multiple dryer systems, a more frequent inspection is intact and free from the exhaust hood. Weighted damper (each dryer) C. Operate the dryer and verify that the exhaust air is not obstructed in the vent and that ...in the system. ■ Seal any lint accumulation. ■ Be sure that it is recommended. A B C E D A. Central vertical duct - Outside air source DRYER INSPECTION AND CLEANING Frequency of the exhaust system. In commercial usage or in high-rise apartments, with a bank of...
Installation Guide
Page 1
... INSTRUCTIONS Table of Contents DRYER SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 LOCATION REQUIREMENTS 4 ELECTRICAL REQUIREMENTS 5 INSTALL LEVELING LEGS 6 ELECTRICAL INSTALLATION 7 Power Supply Cord Connection 8 Direct Wire Connection 10 VENTING...Vent System 14 CONNECT INLET HOSE (STEAM MODEL ONLY 15 CONNECT VENT 16 LEVEL DRYER 17 COMPLETE INSTALLATION CHECKLIST 17 DOOR REVERSAL (OPTIONAL 18 Para una version de estas instrucciones en español, visite www.Whirlpool.com INSTALLATION NOTES Date of purchase Date of installation Installer Model number Serial number...
... INSTRUCTIONS Table of Contents DRYER SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 LOCATION REQUIREMENTS 4 ELECTRICAL REQUIREMENTS 5 INSTALL LEVELING LEGS 6 ELECTRICAL INSTALLATION 7 Power Supply Cord Connection 8 Direct Wire Connection 10 VENTING...Vent System 14 CONNECT INLET HOSE (STEAM MODEL ONLY 15 CONNECT VENT 16 LEVEL DRYER 17 COMPLETE INSTALLATION CHECKLIST 17 DOOR REVERSAL (OPTIONAL 18 Para una version de estas instrucciones en español, visite www.Whirlpool.com INSTALLATION NOTES Date of purchase Date of installation Installer Model number Serial number...
Installation Guide
Page 2
DRYER SAFETY IMPORTANT: When discarding or storing your old clothes dryer, remove the door. 2
DRYER SAFETY IMPORTANT: When discarding or storing your old clothes dryer, remove the door. 2
Installation Guide
Page 3
... that opens to 1" (25 mm) or hex-head socket wrench "Y" connector Parts package is located in ring terminals or spade terminals with dryer) ■■Vent clamps ■■Vent elbows and vent work Parts needed : Parts supplied (all parts are included. The cord should... cord kit marked for your "Use and Care Guide" for information about accessories available for use leveling legs supplied with dryer if installing with clothes dryers. Parts needed: (Not supplied with upturned ends. ■■A UL listed strain relief. INSTALLATION REQUIREMENTS TOOLS AND PARTS...
... that opens to 1" (25 mm) or hex-head socket wrench "Y" connector Parts package is located in ring terminals or spade terminals with dryer) ■■Vent clamps ■■Vent elbows and vent work Parts needed : Parts supplied (all parts are included. The cord should... cord kit marked for your "Use and Care Guide" for information about accessories available for use leveling legs supplied with dryer if installing with clothes dryers. Parts needed: (Not supplied with upturned ends. ■■A UL listed strain relief. INSTALLATION REQUIREMENTS TOOLS AND PARTS...
Installation Guide
Page 4
...appliances and clearances for proper exhaust installation. If a closet door or louvered door is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. Contact your local building inspector. You may use the water supply for your washer using power supply... ft. (1.2 m) of the water fill valves, and water pressure of installation and servicing; IMPORTANT: Do not operate, install, or store dryer where it will be installed or stored in garages, closets, mobile homes, or sleeping quarters. LOCATION REQUIREMENTS Check code requirements. See "Electrical Requirements...
...appliances and clearances for proper exhaust installation. If a closet door or louvered door is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. Contact your local building inspector. You may use the water supply for your washer using power supply... ft. (1.2 m) of the water fill valves, and water pressure of installation and servicing; IMPORTANT: Do not operate, install, or store dryer where it will be installed or stored in garages, closets, mobile homes, or sleeping quarters. LOCATION REQUIREMENTS Check code requirements. See "Electrical Requirements...
Installation Guide
Page 5
... using and follow the instructions provided for it is recommended that a qualified electrician determine that the electrical connection is allowed. Louvered doors with clothes dryers. Recommended installation clearances (dryer only): 18" min. (457 mm) 3" (76 mm) 48 in.2 min. (310 cm2) 5" * (127 mm) 24 in.2 min. (...least 4 ft. (1.22 m) long. The wires that connect to the neutral wire, see "Assistance or Service" section in your dryer, you must be made in the neutral or grounding circuit. ■■Do not use with equivalent ventilation openings are required. Additional...
... using and follow the instructions provided for it is recommended that a qualified electrician determine that the electrical connection is allowed. Louvered doors with clothes dryers. Recommended installation clearances (dryer only): 18" min. (457 mm) 3" (76 mm) 48 in.2 min. (310 cm2) 5" * (127 mm) 24 in.2 min. (...least 4 ft. (1.22 m) long. The wires that connect to the neutral wire, see "Assistance or Service" section in your dryer, you must be made in the neutral or grounding circuit. ■■Do not use with equivalent ventilation openings are required. Additional...
Installation Guide
Page 6
... direct wire: Power supply cable must be either green or bare. Screw in leveling legs diamond marking Examine leveling legs, find diamond marking. Slide the dryer on cardboard. 2. To avoid damaging floor, use aluminum) at least 4 ft. (1.22 m) long, must have three 10-gauge copper wires and ... LEGS 3-wire receptacle (10-30R) Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. Stand the dryer up. If your outlet looks like this: 4-wire receptacle (14-30R) Then choose a 4-wire power supply cord with ring or spade terminals and...
... direct wire: Power supply cable must be either green or bare. Screw in leveling legs diamond marking Examine leveling legs, find diamond marking. Slide the dryer on cardboard. 2. To avoid damaging floor, use aluminum) at least 4 ft. (1.22 m) long, must have three 10-gauge copper wires and ... LEGS 3-wire receptacle (10-30R) Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. Stand the dryer up. If your outlet looks like this: 4-wire receptacle (14-30R) Then choose a 4-wire power supply cord with ring or spade terminals and...
Installation Guide
Page 8
Attach power supply cord to strain relief 4-wire receptacle (NEMA type 14-30R) 4-prong plug Spade terminals with the dryer cabinet and be in place. Tighten strain relief screws just enough to "4-Wire Power Supply Cord Connection" on page 9. 8 Remove center terminal block screw (B). The ...
Attach power supply cord to strain relief 4-wire receptacle (NEMA type 14-30R) 4-prong plug Spade terminals with the dryer cabinet and be in place. Tighten strain relief screws just enough to "4-Wire Power Supply Cord Connection" on page 9. 8 Remove center terminal block screw (B). The ...
Installation Guide
Page 9
... Ring terminals Connect remaining wires under outer terminal block screws. Remove center screw A B F Connect ground wire (F) (green or bare) of dryer rear panel. Connect neutral wire (white or center) (C) of dryer rear panel. Now, go to "Venting Requirements". 3-Wire Power Supply Cord Connection Use where local codes permit connecting cabinet-ground conductor...
... Ring terminals Connect remaining wires under outer terminal block screws. Remove center screw A B F Connect ground wire (F) (green or bare) of dryer rear panel. Connect neutral wire (white or center) (C) of dryer rear panel. Now, go to "Venting Requirements". 3-Wire Power Supply Cord Connection Use where local codes permit connecting cabinet-ground conductor...
Installation Guide
Page 10
... external ground conductor screw (A). 3. Strip insulation back 1" (25 mm). The strain relief should have 5 ft. (1.52 m) of extra length so dryer may be in a horizontal position. If your 4-wire cable for mobile homes and where local codes do not permit 3-wire connections. 1. Shape ends of ...is required for direct connection 31 (89 ⁄2" mm) (251"mm) (127 5" mm) Direct wire cable must have a tight fit with the dryer cabinet and be moved if needed. Tighten strain relief screw against the direct wire cable. Attach direct wire strain relief A B C Unscrew the removable ...
... external ground conductor screw (A). 3. Strip insulation back 1" (25 mm). The strain relief should have 5 ft. (1.52 m) of extra length so dryer may be in a horizontal position. If your 4-wire cable for mobile homes and where local codes do not permit 3-wire connections. 1. Shape ends of ...is required for direct connection 31 (89 ⁄2" mm) (251"mm) (127 5" mm) Direct wire cable must have a tight fit with the dryer cabinet and be moved if needed. Tighten strain relief screw against the direct wire cable. Attach direct wire strain relief A B C Unscrew the removable ...
Installation Guide
Page 11
...(C) of direct wire cable under outer terminal block screws (hooks facing right). Strip 31/2" (89 mm) of outer covering from end of dryer rear panel. Now, go to "Venting Requirements". 3-Wire Direct Wire Connection Use where local codes permit connecting cabinet-ground conductor to "Venting ...52 m) of direct wire cable under outer terminal block screws (hooks facing right). 4. Connect neutral wire B C Place hooked ends of dryer rear panel. Secure cover with hold -down screw. Remove center screw A B F Connect ground wire (green or bare) (F) of extra length so...
...(C) of direct wire cable under outer terminal block screws (hooks facing right). Strip 31/2" (89 mm) of outer covering from end of dryer rear panel. Now, go to "Venting Requirements". 3-Wire Direct Wire Connection Use where local codes permit connecting cabinet-ground conductor to "Venting ...52 m) of direct wire cable under outer terminal block screws (hooks facing right). 4. Connect neutral wire B C Place hooked ends of dryer rear panel. Secure cover with hold -down screw. Remove center screw A B F Connect ground wire (green or bare) (F) of extra length so...
Installation Guide
Page 12
...EXHAUSTED OUTDOORS. Tighten screw. 3. Connect remaining wires WARNING: To reduce the risk of remaining wires under outer terminal block screws. Dryer exhaust must verify with hold-down screw. Place ends of fire, this grounding method is acceptable before connecting. 4. Tighten screws. ...or metal foil vent. Optional External Ground for 3-Wire Connection (Power Supply Cord Shown) IMPORTANT: You must not be connected into slot of dryer rear panel. Remove neutral ground wire (E) from green external ground conductor screw (A). Now, go to connect neutral ground wire and neutral wire...
...EXHAUSTED OUTDOORS. Tighten screw. 3. Connect remaining wires WARNING: To reduce the risk of remaining wires under outer terminal block screws. Dryer exhaust must verify with hold-down screw. Place ends of fire, this grounding method is acceptable before connecting. 4. Tighten screws. ...or metal foil vent. Optional External Ground for 3-Wire Connection (Power Supply Cord Shown) IMPORTANT: You must not be connected into slot of dryer rear panel. Remove neutral ground wire (E) from green external ground conductor screw (A). Now, go to connect neutral ground wire and neutral wire...
Installation Guide
Page 13
... E G Louvered Hood Acceptable Style: Box Hood Angled Hood Elbows: ■■ 45° elbows provide better airflow than 90° elbows. Dryer E. Vent length necessary to achieve best drying performance. Rigid metal or flexible metal vent C. Rigid metal vent: ■■ Recommended for best drying...A. Elbow F. Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in final dryer location. ■■ Remove excess to seal all joints. ■■ Exhaust vent must be connected or secured with screws or...
... E G Louvered Hood Acceptable Style: Box Hood Angled Hood Elbows: ■■ 45° elbows provide better airflow than 90° elbows. Dryer E. Vent length necessary to achieve best drying performance. Rigid metal or flexible metal vent C. Rigid metal vent: ■■ Recommended for best drying...A. Elbow F. Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in final dryer location. ■■ Remove excess to seal all joints. ■■ Exhaust vent must be connected or secured with screws or...
Installation Guide
Page 14
... (10.7 m) 29 ft. (8.8 m) 4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m) NOTE: Side and bottom exhaust installations have the dryer converted. Install Vent System 1. Terminate exhaust vent outside. NOTE: Do not use fewest number of elbows and turns. ■■When using elbows or making... that will : ■■Shorten life of vent material and hood combinations acceptable to use caulking compound to determine type of dryer. ■■Reduce performance, resulting in "Vent System Chart". A B C A. Bottom exhaust installation Special provisions for best drying...
... (10.7 m) 29 ft. (8.8 m) 4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m) NOTE: Side and bottom exhaust installations have the dryer converted. Install Vent System 1. Terminate exhaust vent outside. NOTE: Do not use fewest number of elbows and turns. ■■When using elbows or making... that will : ■■Shorten life of vent material and hood combinations acceptable to use caulking compound to determine type of dryer. ■■Reduce performance, resulting in "Vent System Chart". A B C A. Bottom exhaust installation Special provisions for best drying...
Installation Guide
Page 15
...it is seated on connector. 3. Attach washer cold inlet hose to other fastening devices that extend into interior of "Y" connector. Damage to dryer location using the new inlet hoses (not supplied). Run vent to the coupling can catch lint. Use clamps to the cold water faucet using... straightest path possible. The dryer must fit over the exhaust hood. Periodically inspect and replace hoses if bulges, kinks, cuts, wear, or leaks are found. Tighten couplings 1....
...it is seated on connector. 3. Attach washer cold inlet hose to other fastening devices that extend into interior of "Y" connector. Damage to dryer location using the new inlet hoses (not supplied). Run vent to the coupling can catch lint. Use clamps to the cold water faucet using... straightest path possible. The dryer must fit over the exhaust hood. Periodically inspect and replace hoses if bulges, kinks, cuts, wear, or leaks are found. Tighten couplings 1....
Installation Guide
Page 16
... (102 mm) clamp, connect vent to final location Check that vent is clean. 5. Attach long hose to exhaust outlet Remove protective cap from under dryer. NOTE: Do not overtighten. Damage to existing vent, make sure vent is secured to crush or kink vent. Check for leaks Move... dryer to final location, taking care not to exhaust hood with a 4" (102 mm) clamp. 2. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood. If connecting to the coupling can result. 6. Attach ...
... (102 mm) clamp, connect vent to final location Check that vent is clean. 5. Attach long hose to exhaust outlet Remove protective cap from under dryer. NOTE: Do not overtighten. Damage to existing vent, make sure vent is secured to crush or kink vent. Check for leaks Move... dryer to final location, taking care not to exhaust hood with a 4" (102 mm) clamp. 2. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood. If connecting to the coupling can result. 6. Attach ...