Use & Care Guide
Page 1
... CM) RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301 or visit our website at www.whirlpool.com In Canada, call 1-800-807-6777 or visit our website at www.whirlpool.ca HOTTE D'ASPIRATION...installation ou service, composer le 1-800-807-6777 ou visiter notre site Web à www.whirlpool.ca Table of Contents/Table des matières 2 Models/Modèles: UXT5230AY/UXT5236AY IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. LI3Z5B/W10400323D FOR RESIDENTIAL USE ONLY. POUR UTILISATION ...
... CM) RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301 or visit our website at www.whirlpool.com In Canada, call 1-800-807-6777 or visit our website at www.whirlpool.ca HOTTE D'ASPIRATION...installation ou service, composer le 1-800-807-6777 ou visiter notre site Web à www.whirlpool.ca Table of Contents/Table des matières 2 Models/Modèles: UXT5230AY/UXT5236AY IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. LI3Z5B/W10400323D FOR RESIDENTIAL USE ONLY. POUR UTILISATION ...
Use & Care Guide
Page 2
... 4 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 9 Make Electrical Connection 11 Complete Installation 11 RANGE HOOD USE 12 Range Hood Controls 12 RANGE HOOD CARE 12 Cleaning 12 WIRING DIAGRAM 14 ASSISTANCE OR SERVICE 15 In the U.S.A 15 In Canada 15...Nettoyage 28 SCHÉMA DE CÂBLAGE 30 ASSISTANCE OU SERVICE 31 Au Canada 31 Accessoires 31 GARANTIE 31 RANGE HOOD SAFETY Your safety and the safety of injury, and tell you what can be killed or seriously injured if you don...
... 4 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 9 Make Electrical Connection 11 Complete Installation 11 RANGE HOOD USE 12 Range Hood Controls 12 RANGE HOOD CARE 12 Cleaning 12 WIRING DIAGRAM 14 ASSISTANCE OR SERVICE 15 In the U.S.A 15 In Canada 15...Nettoyage 28 SCHÉMA DE CÂBLAGE 30 ASSISTANCE OU SERVICE 31 Au Canada 31 Accessoires 31 GARANTIE 31 RANGE HOOD SAFETY Your safety and the safety of injury, and tell you what can be killed or seriously injured if you don...
Use & Care Guide
Page 3
...: - Heat oils slowly on "Kitchen Fire Safety Tips" published by qualified person(s) in accordance with a close fitting lid, cookie sheet, or metal tray, then turn hood ON when cooking at high heat or when flambeing food (i.e. WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP...
...: - Heat oils slowly on "Kitchen Fire Safety Tips" published by qualified person(s) in accordance with a close fitting lid, cookie sheet, or metal tray, then turn hood ON when cooking at high heat or when flambeing food (i.e. WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP...
Use & Care Guide
Page 4
...local codes. See "Electrical Requirements" section. ■ All openings in ceiling and wall where range hood will be installed must be sealed. ■ These range hoods are capable of this range hood must be away from package. Check that all governing codes and ordinances. ■ It is a...bit 3.0 mm) drill bit for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is located inside the range hood on ordering, see the "Accessories" section. ■ 7" (17.8 cm) round vent mounting plate. For Mobile Home Installations The installation of being...
...local codes. See "Electrical Requirements" section. ■ All openings in ceiling and wall where range hood will be installed must be sealed. ■ These range hoods are capable of this range hood must be away from package. Check that all governing codes and ordinances. ■ It is a...bit 3.0 mm) drill bit for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is located inside the range hood on ordering, see the "Accessories" section. ■ 7" (17.8 cm) round vent mounting plate. For Mobile Home Installations The installation of being...
Use & Care Guide
Page 5
... is a minimum of 24" (61 cm) of straight vent between the elbows if more than specified CFM of air movement. Roof cap with the range hood. ■ Use caulking to seal exterior wall or roof opening width for vent system. B. to 30" (76.2 cm) suggested max. - Makeup Air Local...makeup air systems when using ventilation systems greater than 1 elbow is not recommended. The damper should be on your area. clearance - bottom of range hood to locale. Plastic or metal foil vent is recommended. B. The break should be as close as part of the vent system. Rigid metal vent ...
... is a minimum of 24" (61 cm) of straight vent between the elbows if more than specified CFM of air movement. Roof cap with the range hood. ■ Use caulking to seal exterior wall or roof opening width for vent system. B. to 30" (76.2 cm) suggested max. - Makeup Air Local...makeup air systems when using ventilation systems greater than 1 elbow is not recommended. The damper should be on your area. clearance - bottom of range hood to locale. Plastic or metal foil vent is recommended. B. The break should be as close as part of the vent system. Rigid metal vent ...
Use & Care Guide
Page 6
... circuit is located behind the filter on the model/serial rating plate. A copy of the appliance as specified on the rear wall of the range hood. ■ Wire sizes must conform with local codes and industry accepted wiring practices. ■ Wire sizes and connections must conform to the pigtail leads. 2. Connect...
... circuit is located behind the filter on the model/serial rating plate. A copy of the appliance as specified on the rear wall of the range hood. ■ Wire sizes must conform with local codes and industry accepted wiring practices. ■ Wire sizes and connections must conform to the pigtail leads. 2. Connect...
Use & Care Guide
Page 7
... 1¹⁄₄" (3.2 cm) diameter wiring access hole. Drill a 1¼" (3.2 cm) diameter hole through wall: 1. Lift the range hood and set it upside down onto covered surface. 5. Mark a line distance "A" from the underside of the cabinet. Mark the point on the ...(8.3 cm x 25.4 cm) Rectangular Vent System Roof Venting To make sure there is proper clearance within the ceiling or wall for assembling the range hood. INSTALLATION INSTRUCTIONS Prepare Location NOTE: It is recommended that the vent system be made. ⁷⁄₈" (2.2 cm) A Centerline A. 8³⁄...
... 1¹⁄₄" (3.2 cm) diameter wiring access hole. Drill a 1¼" (3.2 cm) diameter hole through wall: 1. Lift the range hood and set it upside down onto covered surface. 5. Mark a line distance "A" from the underside of the cabinet. Mark the point on the ...(8.3 cm x 25.4 cm) Rectangular Vent System Roof Venting To make sure there is proper clearance within the ceiling or wall for assembling the range hood. INSTALLATION INSTRUCTIONS Prepare Location NOTE: It is recommended that the vent system be made. ⁷⁄₈" (2.2 cm) A Centerline A. 8³⁄...
Use & Care Guide
Page 9
...vent mounting plate (see the "Accessories" section. Leave about ¹⁄₄" (6.4 cm) space between screw heads and cabinet to range hood with the 3.5 x 5 mm screws provided and remove tape from the rear channel. Remove vent knockouts depending on your installation requirements. 2. ...4 - 4.5 mm x 13 mm mounting screws in pilot holes. Round vent knockout E. See the "Range Hood Care" section. 7. Set range hood aside on the range hood. Keyhole slot 5. Rear rectangular vent knockout Round vent system installations - For wall installations, remove the rear rectangular ...
...vent mounting plate (see the "Accessories" section. Leave about ¹⁄₄" (6.4 cm) space between screw heads and cabinet to range hood with the 3.5 x 5 mm screws provided and remove tape from the rear channel. Remove vent knockouts depending on your installation requirements. 2. ...4 - 4.5 mm x 13 mm mounting screws in pilot holes. Round vent knockout E. See the "Range Hood Care" section. 7. Set range hood aside on the range hood. Keyhole slot 5. Rear rectangular vent knockout Round vent system installations - For wall installations, remove the rear rectangular ...
Use & Care Guide
Page 10
... (8.3 x 25.4 cm) rectangular vent damper can be enough wiring from the fused disconnect (or circuit breaker) box to make the connection in the hood electrical terminal box. A A B A. A B A. Tighten the mounting screws, making sure the screws are in the "Make Electrical Connection" section. ... codes and ordinances. Vent knockouts E. Screws A. For optional power supply cord kit installations, follow the instructions in the neck of the vent hood (depending on ordering. B A C D E Power Supply Cable Installation 1. NOTE: Do not reconnect power until the installation is complete. ...
... (8.3 x 25.4 cm) rectangular vent damper can be enough wiring from the fused disconnect (or circuit breaker) box to make the connection in the hood electrical terminal box. A A B A. A B A. Tighten the mounting screws, making sure the screws are in the "Make Electrical Connection" section. ... codes and ordinances. Vent knockouts E. Screws A. For optional power supply cord kit installations, follow the instructions in the neck of the vent hood (depending on ordering. B A C D E Power Supply Cable Installation 1. NOTE: Do not reconnect power until the installation is complete. ...
Use & Care Guide
Page 11
...the front mounting flange. Place the back of the panel into the rear channel and push the panel toward the back of the range hood until the tabs on the front of the panel up into the front mounting flange until the panel tabs align with the slots in... death or electrical shock. 1. b. See the "Range Hood Care" section. 3. G C D E A B F A. Fire Hazard Electrically ground the blower. Install terminal box cover. 6. Release the panel so the tabs lock the panel in terminal...
...the front mounting flange. Place the back of the panel into the rear channel and push the panel toward the back of the range hood until the tabs on the front of the panel up into the front mounting flange until the panel tabs align with the slots in... death or electrical shock. 1. b. See the "Range Hood Care" section. 3. G C D E A B F A. Fire Hazard Electrically ground the blower. Install terminal box cover. 6. Release the panel so the tabs lock the panel in terminal...
Use & Care Guide
Page 12
...or Service" section to the following instructions. Dispose of the filter. Halogen lights B. Filter retainer Range Hood Controls A B CD RANGE HOOD CARE Cleaning IMPORTANT: Clean the hood and grease filters frequently according to order. ■ Liquid detergent or all smoke and odors from the...avoid damage to remove smoke, cooking vapors and odors from the filter retainer. 2. Screw B. For best results, start the hood before operating hood. Exterior Surfaces: IMPORTANT: Do not use cleaners that contain chlorine. Press once for On and again for quiet operation. Remove...
...or Service" section to the following instructions. Dispose of the filter. Halogen lights B. Filter retainer Range Hood Controls A B CD RANGE HOOD CARE Cleaning IMPORTANT: Clean the hood and grease filters frequently according to order. ■ Liquid detergent or all smoke and odors from the...avoid damage to remove smoke, cooking vapors and odors from the filter retainer. 2. Screw B. For best results, start the hood before operating hood. Exterior Surfaces: IMPORTANT: Do not use cleaners that contain chlorine. Press once for On and again for quiet operation. Remove...
Use & Care Guide
Page 13
...lamp and replace it clockwise to secure the filter. 4. Reconnect power. 13 Disconnect power. 2. Pull the filter retainer toward the front of the range hood and push the front of the filter up on the long edge of the filter is to be toward the front of the new lamp... the lamps are inserted correctly before calling service. 1. Replacing the Halogen Lamp Turn off the range hood and allow the halogen lamp to handle lamp. To avoid damage or decreasing the life of the range hood. Repeat steps 2-3 for the other lamps if needed. 5. Push up into place. 4. Turn it with ...
...lamp and replace it clockwise to secure the filter. 4. Reconnect power. 13 Disconnect power. 2. Pull the filter retainer toward the front of the range hood and push the front of the filter up on the long edge of the filter is to be toward the front of the new lamp... the lamps are inserted correctly before calling service. 1. Replacing the Halogen Lamp Turn off the range hood and allow the halogen lamp to handle lamp. To avoid damage or decreasing the life of the range hood. Repeat steps 2-3 for the other lamps if needed. 5. Push up into place. 4. Turn it with ...
Installation Guide
Page 1
..." (76.2 CM) AND 36" (91.4 CM) RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301 or visit our website at www.whirlpool.com In Canada, call 1-800-807-6777 or visit our ...assistance, installation ou service, composer le 1-800-807-6777 ou visiter notre site Web à www.whirlpool.ca Table of Contents/Table des matières 2 Models/Modèles: UXT5230AY/UXT5236AY IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT. FOR RESIDENTIAL USE ONLY....
..." (76.2 CM) AND 36" (91.4 CM) RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301 or visit our website at www.whirlpool.com In Canada, call 1-800-807-6777 or visit our ...assistance, installation ou service, composer le 1-800-807-6777 ou visiter notre site Web à www.whirlpool.ca Table of Contents/Table des matières 2 Models/Modèles: UXT5230AY/UXT5236AY IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT. FOR RESIDENTIAL USE ONLY....
Installation Guide
Page 2
... Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 9 Make Electrical Connection 11 Complete Installation 11 RANGE HOOD USE 12 Range Hood Controls 12 RANGE HOOD CARE 12 Cleaning 12 WIRING DIAGRAM 14 ASSISTANCE OR SERVICE 15 In the U.S.A 15 In Canada ...Nettoyage 28 SCHÉMA DE CÂBLAGE 30 ASSISTANCE OU SERVICE 31 Au Canada 31 Accessoires 31 GARANTIE 31 RANGE HOOD SAFETY Your safety and the safety of injury, and tell you don't follow instructions. WARNING You can be killed ...
... Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 9 Make Electrical Connection 11 Complete Installation 11 RANGE HOOD USE 12 Range Hood Controls 12 RANGE HOOD CARE 12 Cleaning 12 WIRING DIAGRAM 14 ASSISTANCE OR SERVICE 15 In the U.S.A 15 In Canada ...Nettoyage 28 SCHÉMA DE CÂBLAGE 30 ASSISTANCE OU SERVICE 31 Au Canada 31 Accessoires 31 GARANTIE 31 RANGE HOOD SAFETY Your safety and the safety of injury, and tell you don't follow instructions. WARNING You can be killed ...
Installation Guide
Page 3
.... ■ Use an extinguisher ONLY if: - You can fight the fire with any fan with a close fitting lid, cookie sheet, or metal tray, then turn hood ON when cooking at high settings. BE CAREFUL TO PREVENT BURNS. The fire department is being switched on low or medium settings. ■ Always turn...
.... ■ Use an extinguisher ONLY if: - You can fight the fire with any fan with a close fitting lid, cookie sheet, or metal tray, then turn hood ON when cooking at high settings. BE CAREFUL TO PREVENT BURNS. The fire department is being switched on low or medium settings. ■ Always turn...
Installation Guide
Page 4
...-vented (recirculation) installations: ■ Charcoal filter kit. Given dimensions provide minimum clearance. For information on the left wall. ■ Range hood location should be away from strong draft areas, such as windows, doors and strong heating vents. ■ Cabinet opening dimensions that are included...or 8" (20.3 cm) circle template Parts supplied Remove parts from package. The model/serial rating plate is located inside the range hood on ordering, see the "Accessories" section. ■ 7" (17.8 cm) round vent mounting plate. Consult the cooktop/range manufacturer...
...-vented (recirculation) installations: ■ Charcoal filter kit. Given dimensions provide minimum clearance. For information on the left wall. ■ Range hood location should be away from strong draft areas, such as windows, doors and strong heating vents. ■ Cabinet opening dimensions that are included...or 8" (20.3 cm) circle template Parts supplied Remove parts from package. The model/serial rating plate is located inside the range hood on ordering, see the "Accessories" section. ■ 7" (17.8 cm) round vent mounting plate. Consult the cooktop/range manufacturer...
Installation Guide
Page 5
...8324;" x 10" (8.3 x 25.4 cm) rectangular with a maximum vent length of 35 ft (10.7 m) or 7" (17.8 cm) or larger round vent with the range hood. ■ Use caulking to 30" (76.2 cm) max. Consult your area. above the cooking surface A. 7" (17.8 cm) round vent out the top and through the... and a thermal break should be installed to minimize conduction of outside temperatures as possible to where the vent system enters the heated portion of range hood to cooking surface C. 30" (76.2 cm) min. The damper should be on your installation requirement. Plastic or metal foil vent is used. ...
...8324;" x 10" (8.3 x 25.4 cm) rectangular with a maximum vent length of 35 ft (10.7 m) or 7" (17.8 cm) or larger round vent with the range hood. ■ Use caulking to 30" (76.2 cm) max. Consult your area. above the cooking surface A. 7" (17.8 cm) round vent out the top and through the... and a thermal break should be installed to minimize conduction of outside temperatures as possible to where the vent system enters the heated portion of range hood to cooking surface C. 30" (76.2 cm) min. The damper should be on your installation requirement. Plastic or metal foil vent is used. ...
Installation Guide
Page 6
...; elbow (1.5 m) Example vent system 7" (17.8 cm) round 90˚ elbow 6 ft (1.8 m) Wall cap 2 ft (0.6 m) Maximum Recommended Length 1 - 90° elbow 1 - Connect a section of the range hood. ■ Wire sizes must conform with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22...
...; elbow (1.5 m) Example vent system 7" (17.8 cm) round 90˚ elbow 6 ft (1.8 m) Wall cap 2 ft (0.6 m) Maximum Recommended Length 1 - 90° elbow 1 - Connect a section of the range hood. ■ Wire sizes must conform with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22...
Installation Guide
Page 7
...for 30" (76.2 cm) models 11³⁄₈" (28.9 cm) for 36" (91.4 cm) models A A. See Step 2 for assembling the range hood. Disconnect power. Mark a line distance "A" from the back wall on this point. Drill a 1¹⁄₄" (3.2 cm) diameter hole through wall: 1. Cut...8324;" (12.1 cm) from the right of the centerline on your model, determine which venting method to cut a rectangular opening will be installed before hood is installed. Before making cutouts, make a 4¹⁄₄" x 10½" (10.8 cm x 26.7 cm) rectangular cutout on the underside...
...for 30" (76.2 cm) models 11³⁄₈" (28.9 cm) for 36" (91.4 cm) models A A. See Step 2 for assembling the range hood. Disconnect power. Mark a line distance "A" from the back wall on this point. Drill a 1¹⁄₄" (3.2 cm) diameter hole through wall: 1. Cut...8324;" (12.1 cm) from the right of the centerline on your model, determine which venting method to cut a rectangular opening will be installed before hood is installed. Before making cutouts, make a 4¹⁄₄" x 10½" (10.8 cm x 26.7 cm) rectangular cutout on the underside...
Installation Guide
Page 9
...pull the panel away from damper flap. Remove the 3¼" x 10" (8.3 x 25.4 cm) rectangular vent damper taped on the range hood. Round vent knockout B. Rear rectangular vent knockout Round vent system installations - Remove top rectangular and round vent knockouts. Non-vent (recirculating) ... plate or 3¼" x 10" (8.3 x 25.4 cm) rectangular vent damper, depending on the front of the panel clear the front mounting flange. Attach to slide range hood into place. ¹⁄₄" (6.4 mm) E A. 7" (17.8 cm) Round damper (see "Accessories" section) B. 3.5 x 5 mm screws C. 7" (17...
...pull the panel away from damper flap. Remove the 3¼" x 10" (8.3 x 25.4 cm) rectangular vent damper taped on the range hood. Round vent knockout B. Rear rectangular vent knockout Round vent system installations - Remove top rectangular and round vent knockouts. Non-vent (recirculating) ... plate or 3¼" x 10" (8.3 x 25.4 cm) rectangular vent damper, depending on the front of the panel clear the front mounting flange. Attach to slide range hood into place. ¹⁄₄" (6.4 mm) E A. 7" (17.8 cm) Round damper (see "Accessories" section) B. 3.5 x 5 mm screws C. 7" (17...