Installation Guide
Page 1
... 9 10 - 11 12 13 Before you start Electrical requirements Product dimensions Cabinet dimensions Countertop cutout dimensions Vent system requirements Interior-mounted vent motor Installation steps Vent system requirements Exterior-mounted vent motor Installation steps Use and Care Information Accessories Save Installation Instructions for future reference. Homeowner: Keep Installation ... Care Guide 30" (76.2 cm) 36" (91.4 cm) Retractable (Pop-up) Downdraft Vent Systems IMPORTANT: Read and save these instructions. IMPORTANT: Installer: Leave Installation Instructions with the homeowner.
... 9 10 - 11 12 13 Before you start Electrical requirements Product dimensions Cabinet dimensions Countertop cutout dimensions Vent system requirements Interior-mounted vent motor Installation steps Vent system requirements Exterior-mounted vent motor Installation steps Use and Care Information Accessories Save Installation Instructions for future reference. Homeowner: Keep Installation ... Care Guide 30" (76.2 cm) 36" (91.4 cm) Retractable (Pop-up) Downdraft Vent Systems IMPORTANT: Read and save these instructions. IMPORTANT: Installer: Leave Installation Instructions with the homeowner.
Installation Guide
Page 2
... you how to cabinet. Mobile home installation The installation of this manual and on the model/serial rating plate. When installing downdraft vent, the cabinet drawer will follow instructions. Some installations require a countertop deeper than 25" (63.5 cm). See cooktop Installation Instructions ...to comply with "Create-A-Cooktop" modules, the optional support must be installed on page 5. This is the responsibility of the downdraft vent must be 18" (45.7 cm) above the wiring box cover. See installation steps for correct installation. It is the safety alert...
... you how to cabinet. Mobile home installation The installation of this manual and on the model/serial rating plate. When installing downdraft vent, the cabinet drawer will follow instructions. Some installations require a countertop deeper than 25" (63.5 cm). See cooktop Installation Instructions ...to comply with "Create-A-Cooktop" modules, the optional support must be installed on page 5. This is the responsibility of the downdraft vent must be 18" (45.7 cm) above the wiring box cover. See installation steps for correct installation. It is the safety alert...
Installation Guide
Page 3
... Valley Road Cleveland, Ohio 44131-5575 3 WARNING - This unit must be connected with a qualified electrician if you are not sure downdraft vent is located on a separate 15 amp circuit. A U.L.- A wiring diagram is properly grounded. Copies of the standards listed may be grounded...latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 - This downdraft vent should be vented to the requirements of the downdraft vent above the wiring box cover. F. If codes permit and a separate ground wire is used, it is recommended that ...
... Valley Road Cleveland, Ohio 44131-5575 3 WARNING - This unit must be connected with a qualified electrician if you are not sure downdraft vent is located on a separate 15 amp circuit. A U.L.- A wiring diagram is properly grounded. Copies of the standards listed may be grounded...latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 - This downdraft vent should be vented to the requirements of the downdraft vent above the wiring box cover. F. If codes permit and a separate ground wire is used, it is recommended that ...
Installation Guide
Page 4
... Locate power supply junction box at lower right hand rear corner of cabinet. 4 3/8" (9.5 mm) centerline of cooktop cutout Vent system cutout dimensions for 36" (91.4 cm) vent 1-1/2" (3.8 cm) 3/8" (9.5 mm) 16" (40.6 cm) 8" (20.3 cm) 4" (10.2 cm) 3-1/4"x 10" (8.3 cm x 25.4 cm) 16" (40.6 cm) 16" (...cm) See cooktop manufacturer's instructions for this hole. Product dimensions 8-1/4" (21 cm) retractable vent height top trim widths 30" vent (76.2 cm) 36" vent (91.4 cm) 27" (68.6 cm) for 30" (76.2 cm) vent 33" (83.8 cm) for internal blower models only. The cutout locations for cooktop ...
... Locate power supply junction box at lower right hand rear corner of cabinet. 4 3/8" (9.5 mm) centerline of cooktop cutout Vent system cutout dimensions for 36" (91.4 cm) vent 1-1/2" (3.8 cm) 3/8" (9.5 mm) 16" (40.6 cm) 8" (20.3 cm) 4" (10.2 cm) 3-1/4"x 10" (8.3 cm x 25.4 cm) 16" (40.6 cm) 16" (...cm) See cooktop manufacturer's instructions for this hole. Product dimensions 8-1/4" (21 cm) retractable vent height top trim widths 30" vent (76.2 cm) 36" vent (91.4 cm) 27" (68.6 cm) for 30" (76.2 cm) vent 33" (83.8 cm) for internal blower models only. The cutout locations for cooktop ...
Installation Guide
Page 5
...(4.4 cm) (93.0 cm) (58.4 cm) (63.5 cm) GJC3634G* GJC3634L* RCS3614G* RCS3614L* 36" GZ7736XGS (91.4 cm) GZ7936XHS 36" GZ7736XGS (91.4 cm) GZ7936XHS GZ7936XGS GZ7936XGS 35-1/2" 33-1/2" 20-1/2" 2" 2" 36" 23" 25-3/4" (90.2 cm) (85.9 cm) (52.1 cm) (5.1 ...cm) (5.1 cm) (91.4 cm) (58.4 cm) (65.4 cm) 35" 33-1/2" 19" 2-1/2" 3" 37-5/8" 23" 25-5/8" (88.9 cm) (85.9 cm) (48.3 cm) (6.4 cm) (7.6 cm) (95.6 cm) (58.4 cm) (65.1 cm) * Installation with the retractable popup downdraft vent...
...(4.4 cm) (93.0 cm) (58.4 cm) (63.5 cm) GJC3634G* GJC3634L* RCS3614G* RCS3614L* 36" GZ7736XGS (91.4 cm) GZ7936XHS 36" GZ7736XGS (91.4 cm) GZ7936XHS GZ7936XGS GZ7936XGS 35-1/2" 33-1/2" 20-1/2" 2" 2" 36" 23" 25-3/4" (90.2 cm) (85.9 cm) (52.1 cm) (5.1 ...cm) (5.1 cm) (91.4 cm) (58.4 cm) (65.4 cm) 35" 33-1/2" 19" 2-1/2" 3" 37-5/8" 23" 25-5/8" (88.9 cm) (85.9 cm) (48.3 cm) (6.4 cm) (7.6 cm) (95.6 cm) (58.4 cm) (65.1 cm) * Installation with the retractable popup downdraft vent...
Installation Guide
Page 6
... need , add the equivalent feet for 6" (15.2 cm) round vent system. Determine which venting method to provide efficient performance. If it should not exceed the maximum lengths listed in cabinet locations down vent rear vent left vent right vent Vent system installed under a concrete slab into a window well. 12" ...(30.5 cm) minimum wall cap 6" (15.2 cm) round transition PVC sewer pipe 6" (15.2 cm) concrete slab round metal vent 6" (15.2 cm) round PVC coupling 6" (15.2 cm) round sewer pipe window well 6" (15.2 cm) round 90° PVC sewer pipe elbow 6" ...
... need , add the equivalent feet for 6" (15.2 cm) round vent system. Determine which venting method to provide efficient performance. If it should not exceed the maximum lengths listed in cabinet locations down vent rear vent left vent right vent Vent system installed under a concrete slab into a window well. 12" ...(30.5 cm) minimum wall cap 6" (15.2 cm) round transition PVC sewer pipe 6" (15.2 cm) concrete slab round metal vent 6" (15.2 cm) round PVC coupling 6" (15.2 cm) round sewer pipe window well 6" (15.2 cm) round 90° PVC sewer pipe elbow 6" ...
Installation Guide
Page 7
...end caps to the downdraft. Disconnect blower wiring cable. over counter support arm 2. Do not tighten screws. 5. Align top of downdraft vent with each bracket. Determine which direction (down against front of each mounting screw location on gloves and safety glasses. b. Remove 6 ...support brackets to the downdraft. Then mark location of support leg mounting holes on top of the downdraft vent. Down venting: Downdraft vent is installed under plastic clips inside vent base. Remove 4 hex nuts that attach blower box to run from carton and set on the face...
...end caps to the downdraft. Disconnect blower wiring cable. over counter support arm 2. Do not tighten screws. 5. Align top of downdraft vent with each bracket. Determine which direction (down against front of each mounting screw location on gloves and safety glasses. b. Remove 6 ...support brackets to the downdraft. Then mark location of support leg mounting holes on top of the downdraft vent. Down venting: Downdraft vent is installed under plastic clips inside vent base. Remove 4 hex nuts that attach blower box to run from carton and set on the face...
Installation Guide
Page 8
... Retractable section of blower must be installed for proper operation. Reposition brackets on model blower control knob end cap 15. Insert downdraft vent into the wiring box. Carefully drill starter holes through countertop when tightened. 11. Remove the 2 Phillips-head screws attaching the wiring...place. Reinstall blower in terminal box. Connect the black wires together with 2 Phillips-head screws. Position the top trim over vent mounting hole and flange against countertop. WARNING Excessive Weight Hazard Use two or more people to cabinet floor with mouth of ...
... Retractable section of blower must be installed for proper operation. Reposition brackets on model blower control knob end cap 15. Insert downdraft vent into the wiring box. Carefully drill starter holes through countertop when tightened. 11. Remove the 2 Phillips-head screws attaching the wiring...place. Reinstall blower in terminal box. Connect the black wires together with 2 Phillips-head screws. Position the top trim over vent mounting hole and flange against countertop. WARNING Excessive Weight Hazard Use two or more people to cabinet floor with mouth of ...
Installation Guide
Page 9
...length of system you need, add the equivalent feet for easy reference. Check with local codes for 10" (25.4 cm) round vent system. 10" (25.4 cm) round vent system Built-in cabinet location Built-in as far as possible. Check that there is a minimum of 24 inches (61 cm) ... Turn the control knob on page 12. See example for makeup air requirements, if any two elbows. For a longer vent run, or smaller vent system, contact a qualified and trained vent installer. Check that circuit breaker is required, it should be needed. To get the most efficient use no more than ...
...length of system you need, add the equivalent feet for easy reference. Check with local codes for 10" (25.4 cm) round vent system. 10" (25.4 cm) round vent system Built-in cabinet location Built-in as far as possible. Check that there is a minimum of 24 inches (61 cm) ... Turn the control knob on page 12. See example for makeup air requirements, if any two elbows. For a longer vent run, or smaller vent system, contact a qualified and trained vent installer. Check that circuit breaker is required, it should be needed. To get the most efficient use no more than ...
Installation Guide
Page 10
... and wall. Use 1 screw with each leg on top of the downdraft vent during lifting. Two people are recommended to move and install downdraft vent. Cut opening . • Lower edge of downdraft vent. Use a pencil to side of legs until downdraft is not provided. 9.... downdraft. Move support legs down against front of downdraft vent base and adjust position of cutout and that mounting brackets rest gently on Remove downdraft vent from downdraft vent and blower box. 4. Carefully insert downdraft vent into countertop cutout. Attach the left side and right ...
... and wall. Use 1 screw with each leg on top of the downdraft vent during lifting. Two people are recommended to move and install downdraft vent. Cut opening . • Lower edge of downdraft vent. Use a pencil to side of legs until downdraft is not provided. 9.... downdraft. Move support legs down against front of downdraft vent base and adjust position of cutout and that mounting brackets rest gently on Remove downdraft vent from downdraft vent and blower box. 4. Carefully insert downdraft vent into countertop cutout. Attach the left side and right ...
Installation Guide
Page 11
... cooktop according to cabinet floor with a twist-on connector. To get the most efficient use from your new retractable downdraft vent, read the Use and Care Information section on wire connector. Replace wiring box cover. Disconnect power. Keep Installation Instructions and... Use and Care Information close by 3/8" (9.5 mm). Position downdraft vent so it is centered in as far as shown. Insert appropriate length screws into countertop cutout. Connect the black wires together with...
... cooktop according to cabinet floor with a twist-on connector. To get the most efficient use from your new retractable downdraft vent, read the Use and Care Information section on wire connector. Replace wiring box cover. Disconnect power. Keep Installation Instructions and... Use and Care Information close by 3/8" (9.5 mm). Position downdraft vent so it is centered in as far as shown. Insert appropriate length screws into countertop cutout. Connect the black wires together with...
Installation Guide
Page 12
... The fire department is started . Place cooking utensils on cooking surface and turn off , remove utensils from the cooktop area. NOTE: Downdraft vent will begin to the downdraft at high settings. When the service disconnecting means cannot be burned. TO REDUCE THE RISK OF A RANGE TOP... ignite. CAUTION: For general ventilating use large or tall utensils, place them in the dishwasher or in the retractable section of the vent will result. Boilovers cause smoking and greasy spillovers that allows liquids to the service panel. Heat oils slowly on model): Frequently remove...
... The fire department is started . Place cooking utensils on cooking surface and turn off , remove utensils from the cooktop area. NOTE: Downdraft vent will begin to the downdraft at high settings. When the service disconnecting means cannot be burned. TO REDUCE THE RISK OF A RANGE TOP... ignite. CAUTION: For general ventilating use large or tall utensils, place them in the dishwasher or in the retractable section of the vent will result. Boilovers cause smoking and greasy spillovers that allows liquids to the service panel. Heat oils slowly on model): Frequently remove...
Installation Guide
Page 13
... correct defects in materials or workmanship. KITCHENAID SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. In Canada, call 1-800-422-1230. If retractable downdraft vent does not operate after clean filters have been reinstalled: Push the filter in as far as it is installed in an inaccessible location or is...
... correct defects in materials or workmanship. KITCHENAID SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. In Canada, call 1-800-422-1230. If retractable downdraft vent does not operate after clean filters have been reinstalled: Push the filter in as far as it is installed in an inaccessible location or is...
Installation Guide
Page 15
... right) to your telephone directory Yellow Pages. When asking for assistance or service, please provide a detailed description of your vent system and, as appropriate, call the KitchenAid Customer Interaction Center toll-free at 1-800-422-1230 or call our Customer ...assistance (Spanish speaking, hearing impaired, limited vision, etc.) • Referrals to local dealers, service companies, and repair parts distributors Whirlpool-designated service technicians are made to the same exacting specifications used to fulfill the product warranty and provide after-warranty service, anywhere ...
... right) to your telephone directory Yellow Pages. When asking for assistance or service, please provide a detailed description of your vent system and, as appropriate, call the KitchenAid Customer Interaction Center toll-free at 1-800-422-1230 or call our Customer ...assistance (Spanish speaking, hearing impaired, limited vision, etc.) • Referrals to local dealers, service companies, and repair parts distributors Whirlpool-designated service technicians are made to the same exacting specifications used to fulfill the product warranty and provide after-warranty service, anywhere ...
Dimension Guide
Page 1
... cooktop manufacturer's instructions for 6" (15.2 cm) round vent system. Because Whirlpool Corporation policy includes a continuous commitment to 6" (15.2 cm) round vent as soon as possible. B our products, we reserve the right to your specific installation. ® Retractable Downdraft Vent System PRODUCT MODEL NUMBERS GZ7930XG GZ7930XH GZ7936XG GZ7936XH Electrical: 120-volt, 60-Hz, AC-only, 15...
... cooktop manufacturer's instructions for 6" (15.2 cm) round vent system. Because Whirlpool Corporation policy includes a continuous commitment to 6" (15.2 cm) round vent as soon as possible. B our products, we reserve the right to your specific installation. ® Retractable Downdraft Vent System PRODUCT MODEL NUMBERS GZ7930XG GZ7930XH GZ7936XG GZ7936XH Electrical: 120-volt, 60-Hz, AC-only, 15...