Dimension Guide
Page 1
30" (76 cm) Freestanding Electric Range PRODUCT MODEL NUMBERS GFE461LV GFE471LV WFE301LV WFE361LV WFE364LV WFE366LV WFE371LV WFE374LV WFE381LV WFE114LW WFE115LX RF110AXS RF111PXS RF114PXS RF212PXS RF263LXT RF264LXS Electrical: Range must be connected to the proper electrical voltage and frequency as specified on the left side frame behind the storage drawer panel. CABINET OPENING DIMENSIONS Cabinet opening width E. A C B D E F A. 13" (33.0 cm...
30" (76 cm) Freestanding Electric Range PRODUCT MODEL NUMBERS GFE461LV GFE471LV WFE301LV WFE361LV WFE364LV WFE366LV WFE371LV WFE374LV WFE381LV WFE114LW WFE115LX RF110AXS RF111PXS RF114PXS RF212PXS RF263LXT RF264LXS Electrical: Range must be connected to the proper electrical voltage and frequency as specified on the left side frame behind the storage drawer panel. CABINET OPENING DIMENSIONS Cabinet opening width E. A C B D E F A. 13" (33.0 cm...
Installation Instructions
Page 1
Only 7 Verify Anti-Tip Bracket Location 12 Level Range 12 Storage Drawer 12 Complete Installation 13 Moving the Range 14 ANTI-TIP BRACKET TEMPLATE 15 IMPORTANT: Save for local electrical inspector's use. U.S.A. INSTALLATION INSTRUCTIONS 30" (76 CM) FREESTANDING ELECTRIC RANGES Table of Contents RANGE SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 3 Electrical Requirements - U.S.A. Only 4 INSTALLATION INSTRUCTIONS 6 Unpack Range 6 Install Anti-Tip Bracket 6 Electrical Connection - W10252706B
Only 7 Verify Anti-Tip Bracket Location 12 Level Range 12 Storage Drawer 12 Complete Installation 13 Moving the Range 14 ANTI-TIP BRACKET TEMPLATE 15 IMPORTANT: Save for local electrical inspector's use. U.S.A. INSTALLATION INSTRUCTIONS 30" (76 CM) FREESTANDING ELECTRIC RANGES Table of Contents RANGE SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 3 Electrical Requirements - U.S.A. Only 4 INSTALLATION INSTRUCTIONS 6 Unpack Range 6 Install Anti-Tip Bracket 6 Electrical Connection - W10252706B
Installation Instructions
Page 4
.... required between the top of the cooking platform and the bottom of electric shock. Electrical Requirements - IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for 25" (64.0 cm).... from : National Fire Protection Association One Batterymarch Park Quincy, MA 02269. A freestanding range may be installed next to 22" (55.9 cm) from either cabinet, 5¹⁄₂" (14.0 cm) max. D. 30¹⁄₈" (76.5 cm) min. opening width E. WARNING: Improper connection...
.... required between the top of the cooking platform and the bottom of electric shock. Electrical Requirements - IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for 25" (64.0 cm).... from : National Fire Protection Association One Batterymarch Park Quincy, MA 02269. A freestanding range may be installed next to 22" (55.9 cm) from either cabinet, 5¹⁄₂" (14.0 cm) max. D. 30¹⁄₈" (76.5 cm) min. opening width E. WARNING: Improper connection...