Popular Tripp Lite SU6000RT3UHVXL Manual Pages
Owner's Manual for BP Battery 932487 - Page 2
... lifting and installing them. • Make certain that your local codes for disposal requirements or in a fire. 200801218 93-2487 BP External BP OM.qxd 2/28/2008 11:42 AM Page 2
Introduction
Tripp Lite BP Series External Battery Packs are designed for use with various Tripp Lite UPS systems equipped with insulated handles. Save These Instructions
WARNING! Do...
Owner's Manual for BP Battery 932487 - Page 6
...a depleted condition. Troubleshooting
There is required for service. A battery pack with high heat and/or humidity. Review the installation and operation instructions in a discharged state will issue you plan to store your battery pack for at a price comparable to the cost of your sales receipt. Instead, call Tripp Lite at (773) 869-1233. If the problem requires service, the technician...
Owner's Manual for SmartOnline Single-Phase 6-10kVA UPS 932188 - Page 1
... Optional Connection Power ON/OFF Manual Bypass Operation Operation Service/Warranty and Insurance Specifications Español/Français
2 3 5 9 13 14 15 16 19 20
23/45/67
1111 W. 35th Street • Chicago, IL 60609 USA Customer Support: (773) 869-1234 • Application Services: (773) 869-1236 • www.tripplite.com
Copyright ©2004 Tripp Lite. Select UPS...
Owner's Manual for SmartOnline Single-Phase 6-10kVA UPS 932188 - Page 2
... adequate space around all Tripp Lite SmartOnline Rackmount/Tower UPS Systems and their batteries. Contact with any service work to the UPS, it to an external battery module. • Connect only Tripp Lite battery modules to connecting or disconnecting battery terminals. UPS Connection Warnings
• The power supply for proper ventilation. • Do not install the UPS near magnetic...
Owner's Manual for SmartOnline Single-Phase 6-10kVA UPS 932188 - Page 5
.../AC (INVERTER) LED: This green light will remain lit after the alarm is in setup mode, where this button until you hear a beep to display a different power reading (see "Operation", pg. 18). This LED will illuminate to the rest of the features on each module before installing and operating your UPS is supplying AC power to...
Owner's Manual for SmartOnline Single-Phase 6-10kVA UPS 932188 - Page 8
... Cable: Use this to connect one or more Tripp Lite battery modules to indicate line-fail and low-battery status. Refer to the battery module owner's manual for Power Module Connection (10kVA models only): Use these terminals to connect the transformer module to the battery module owner's manual for access.
3. Features (Rear Panel) continued
Power Module Feature Description (6kVA and 10kVA...
Owner's Manual for SmartOnline Single-Phase 6-10kVA UPS 932188 - Page 9
... expecting full backup capability (particularly
F
if the battery module has been stored for
12 hours. Consult the owner's manual that cables are fitted with your battery module. The battery modules are fully charged
prior to a utility power source. Choose appropriate cabling and protection circuits to the power module's output terminals. Pass a user-supplied cable through...
Owner's Manual for SmartOnline Single-Phase 6-10kVA UPS 932188 - Page 11
... 200V AC. However, before expecting full backup capability (particularly if the battery module has been stored for an extended period) after the UPS system is 200V AC, set the transformer module's switch to 240V AC, but configure the power module to recharge for 12 hours.
Pass a user-supplied cable through the box's left knockout D and...
Owner's Manual for SmartOnline Single-Phase 6-10kVA UPS 932188 - Page 12
...power module does not contain internal batteries and will not supply
power to the transformer module's input terminals.
Set the switch to shipping. If your facility's input voltage is normal. The battery
modules are fully charged prior to match your battery... power module settings must match. this is either 208V AC or 240V AC, the trans-
Replace the top of the battery ...
Owner's Manual for SmartOnline Single-Phase 6-10kVA UPS 932188 - Page 15
... will be performed. The procedure details how to service or replace the power module while supplying equipment connected to "BYPASS". 3. NOTE: since the power module and battery module will be disconnected during the procedure, they will not adequately power down and maintenance/replacement can be unable to supply battery backup support to equipment connected to the transformer module in...
Owner's Manual for SmartOnline Single-Phase 6-10kVA UPS 932188 - Page 16
... a error message.
COLD START*
DIAGNOSTIC MODE FREQ OUT = XXHz
M DIAGNOSTIC MODE
INPUT AC BAD M
DIAGNOSTIC MODE INPUT AC BAD M
DIAGNOSTIC MODE BATTERY OK M
DIAGNOSTIC MODE AC/DC OK M
DIAGNOSTIC MODE TESTING INVERTER
M ON BATTERY MODE LOAD = XXX% X.XXKW
Failed Self-Test
If a problem is cold started, its LCD, call Tripp Lite Technical Support at (773) 869-1234 for service...
Owner's Manual for SmartOnline Single-Phase 6-10kVA UPS 932188 - Page 17
..., it is using battery power to On Battery mode quickly if AC power is interrupted. On Battery mode: The UPS provides AC power from battery backup so long as follows:
Overload Condition 102% - 125% 125% - 150% >150%
Countdown Duration 1 minute 30 seconds Immediate
17 The second line of the overload, as battery power lasts. If its connected batteries are at high efficiency...
Owner's Manual for SmartOnline Single-Phase 6-10kVA UPS 932188 - Page 18
... LCD will display a message if it detects one time, but has returned to its LCD and stops supplying output power to nominal. DC BUS HIGH
SHUT DOWN -
Note: During all these conditions, the "Input," "Output" and "Bypass" LEDs will not provide battery backup in Bypass Mode, the UPS monitors its LCD reports that input...
Owner's Manual for SmartOnline Single-Phase 6-10kVA UPS 932188 - Page 19
... electrical and safety codes set forth by the National Electrical Code (NEC). EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Specifically, TRIPP LITE is simultaneously protected by a Tripp Lite power protection device (UPS, surge suppressor or line conditioner) with Ultimate Lifetime...
Owner's Manual for SmartOnline Single-Phase 6-10kVA UPS 932188 - Page 21
Specifications continued
SU6000RT3UHV and SU10KRT3UHV models include a Power Module and one Battery Module. Model
Input Input Voltage Range Module Input Voltage Input Frequency Input Current Inrush Current Power Factor (Full Load) Efficiency (Full Load/On-Line) Power Module Circuit Breaker
SU6000RT3UHV
156V~276V Single Phase 200/208/240V 50/60 Hz ± 3 Hz 22.6A 0.97 >87% 40A (2 pole...