Owner's Manual for On-Line Tower LCD UPS 933168
Page 3
...• Do not modify the UPS's plug, and do not use an adapter that supplies the UPS should be in series with each battery pack. Do not open the UPS or... requirements or visit www.tripplite.com/UPSbatteryrecycling for two basic external battery pack configurations accessible using Tripp Lite's EXTERNAL BATTERY CONFIGURATION software and a serial port connection to the UPS. UPS Connection Warnings... cords to connect the UPS to an AC outlet. • If the UPS receives power from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output. • The ...
...• Do not modify the UPS's plug, and do not use an adapter that supplies the UPS should be in series with each battery pack. Do not open the UPS or... requirements or visit www.tripplite.com/UPSbatteryrecycling for two basic external battery pack configurations accessible using Tripp Lite's EXTERNAL BATTERY CONFIGURATION software and a serial port connection to the UPS. UPS Connection Warnings... cords to connect the UPS to an AC outlet. • If the UPS receives power from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output. • The ...
Owner's Manual for On-Line Tower LCD UPS 933168
Page 14
... when asserting EPO without AC line present: 1. Verify that require connection to the UPS unit, wait until unit beeps, then release. 3. Reapply AC line power to a latching EPO switch. 3a CAUTION: The EPO port is not a phone line surge suppressor; Using the cable provided, connect the EPO port of...to a user-supplied normally closed or normally open switch according to the circuit diagram (see 3b ). Press ON button until the LCD is 3b completely off Your model may differ. 4-5 14 13-03-138 93-3168-EN.indd 14 3/28/2013 1:05:18 PM Option 2: 1. Reapply AC line power. Now the UPS...
... when asserting EPO without AC line present: 1. Verify that require connection to the UPS unit, wait until unit beeps, then release. 3. Reapply AC line power to a latching EPO switch. 3a CAUTION: The EPO port is not a phone line surge suppressor; Using the cable provided, connect the EPO port of...to a user-supplied normally closed or normally open switch according to the circuit diagram (see 3b ). Press ON button until the LCD is 3b completely off Your model may differ. 4-5 14 13-03-138 93-3168-EN.indd 14 3/28/2013 1:05:18 PM Option 2: 1. Reapply AC line power. Now the UPS...
Owner's Manual for On-Line Tower LCD UPS 933168
Page 15
...a shock can result in electrical shock. Small sparks may be reduced if grounds are connecting match the voltage listed on battery power. CAUTION: Do not open or mutilate batteries. The likelihood of these UPS models. 4a Take out the two screws to ...supplies that the external batteries you are fully inserted into their connectors. this is normal. Basic Connection and Start-Up 4 External Battery Connection Check to ensure that do not have a grounded supply circuit.) NOTE: External battery pack options require configuration using the front panel LCD interface or via Tripp Lite...
...a shock can result in electrical shock. Small sparks may be reduced if grounds are connecting match the voltage listed on battery power. CAUTION: Do not open or mutilate batteries. The likelihood of these UPS models. 4a Take out the two screws to ...supplies that the external batteries you are fully inserted into their connectors. this is normal. Basic Connection and Start-Up 4 External Battery Connection Check to ensure that do not have a grounded supply circuit.) NOTE: External battery pack options require configuration using the front panel LCD interface or via Tripp Lite...