Tripp Lite 9PX1500RTL Support and Manuals
Get Help and Manuals for this Tripp Lite item
This item is in your list!
View All Support Options Below
Free Tripp Lite 9PX1500RTL manuals!
Problems with Tripp Lite 9PX1500RTL?
Ask a Question
Free Tripp Lite 9PX1500RTL manuals!
Problems with Tripp Lite 9PX1500RTL?
Ask a Question
Popular Tripp Lite 9PX1500RTL Manual Pages
Eaton 9PX Lithium-Ion Owners Manual - Page 3
... a grounded supply circuit). Safety of batteries or battery packs.
- When replacing batteries, replace with any part of such shock can result in the indicated order.
• CAUTION - The batteries may explode.
- Product Safety
• To connect the UPS, instructions and operation described in the manual must be energized ven if the systems is inadvertently grounded...
Eaton 9PX Lithium-Ion Owners Manual - Page 6
Table of Contents
6.2 Replacing Batteries ...33 6.3 Replacing the UPS Equipped with a HotSwap MBP 35 6.4 Recycling The Used Equipment ...35 7 Troubleshooting ...37 7.1 Typical Alarms and Faults ...37 7.2 Silencing the Alarm ...38 7.3 Service and Support ...38 7.4 CE Compliance Contact ...39 8 Specifications ...41 8.1 Model Specifications ...41
vi
Eaton 9PX Lithium-Ion P-164001006-Rev 01
Eaton 9PX Lithium-Ion Owners Manual - Page 7
... 9PX, please read this manual. The 9PX range has been designed with local regulations. Product
Eaton 9PX Lithium-Ion P-164001006-Rev 01
1 Before installing your electrical equipment. Eaton ...options available for the disposal of their service life in this manual to take the time to read the booklet presenting the safety instructions. Then follow the indications in compliance ...
Eaton 9PX Lithium-Ion Owners Manual - Page 8
... end of your sensitive electronic equipment from the most common power problems, including power failures, power sags, power surges, brownouts, line...of power disturbances and guard the integrity of its service life, the product must be transported to applicable ...• Extended runtime with up of lost productivity and expensive repairs. The battery may be erratic. The Eaton® 9PX ...
Eaton 9PX Lithium-Ion Owners Manual - Page 14
...[Product type/model] / [Part/Serial number] / [UPS/NMC firmware] / [Com card IPv4], [Com card IPv6], [Com card MAC]
Links to Eaton registration website
2.7 User Settings
The following table... Log data and settings are in all supported languages.
Simulates line failure and battery low
Clears active fault, power usage, battery remaining life, reset NMC, Restore factory settings. Display Functions ...
Eaton 9PX Lithium-Ion Owners Manual - Page 19
...instructions 23 Quick start 24 Mounting kit for 19-inch enclosures
25 2 supports... for tower position
Elements supplied depending on the version or optional 26 NMC communication card (optional, standard on the shipping carton label. IMPORTANT
Check the battery recharge date on Network Bundle models... days to your service representative.
! Chapter 3 Installation
3.1 Inspecting the ...
Eaton 9PX Lithium-Ion Owners Manual - Page 32
... the RPO function before applying your critical load to a Gigabit Ethernet network. The 9PX models have one relay output, three optocouplers outputs (pin- 1/7/8). Overload pre-alarm
(1) Relay output...and off.
UPS Remote Control Functions
6. Signal outputs can be configured (see Settings > Com settings > Output Signals in a variety of networking environments and with different types of...
Eaton 9PX Lithium-Ion Owners Manual - Page 39
... not lay tools or metal parts on the shipping carton label. Refer to your service representative to connecting or disconnecting battery terminals. Contact with any battery wiring or connectors. Contact your local codes for 48 hours after long-term storage. Consider all warnings, cautions, and notes before replacing batteries.
• Servicing should be extremely toxic...
Eaton 9PX Lithium-Ion Owners Manual - Page 41
...module goes ON, indicating that the UPS is a connection error between the HotSwap MBP module and the UPS). 3.
This...the load is normal and will not harm personnel. Set switch 33 to Bypass position. Replacing the UPS Equipped with a HotSwap MBP
1
238...36 15
The HotSwap MBP module makes it possible to service or even replace the UPS without affecting the connected loads. Verify that...
Eaton 9PX Lithium-Ion Owners Manual - Page 43
...specific..., automatic operation and also alert you whenever potential operating problems may occur before the batteries reach 20% capacity.
Eaton... Chapter 7 Troubleshooting
7.1 Typical Alarms and Faults
The Eaton 9PX are designed for shutdown. The following troubleshooting chart to ...
If the condition persists, contact your service representative.
Use the following table describes ...
Eaton 9PX Lithium-Ion Owners Manual - Page 44
... 8 for service:
• Model number • Serial number • Firmware version number • Date of failure or problem • ...specific output overload ranges). The input source is not restricted. UPS Overtemperature
LED is powered but remains in Bypass
Equipment is on .
Allow the UPS to Bypass mode or shuts down the UPS. Check the input connections. see "User Settings...
Eaton 9PX Lithium-Ion Owners Manual - Page 49
... loss of utility)
Power Factor
Up to 0.9
Load Crest Ratio
Up to 3:1
Table 13. Transfer behavior can change (see output mode setting on page 14) Battery mode: 102%~130% :12s >130% :2s Overload warning then transfer to stop output
Output Overload ( Bypass ...
Voltage Waveform
Sinewave
Harmonic Distortion
< 3% THDV on linear load < 5% THDV on nominal Watt/VA. Model Specifications
Table 12.
Eaton 9PX Lithium-Ion Owners Manual - Page 51
Table 15. Battery Rack / Tower configuration
Type Monitoring EBM Battery Cable Length
Model Specifications
Internal Batteries
EBM
1500VA: 48Vdc 2200VA: 72Vdc 3000VA: 72Vdc
9PXEBM48RT: 48Vdc 9PXEBM72RT: 72Vdc
Lithium Iron Phosphate (LFP) battery module Lithium-Ion float service life 8 years /25°C
Integrated battery management system (BMS) for temperature regulation and life cycle ...
Product Datasheet - Page 1
... advanced notice when batteries need replacing.
UPS firmware can damage valuable IT equipment or destroy data. q Provides 80% to keep equipment powered
Package Includes
q 1500VA 1350W 120V 9PX Online Double-Conversion UPS with 8 Outlets
q USB cable
q RS-232 cable
q Rack-mounting hardware
q Tower support stands
q Safety guide
q Quick Start Guide Optional Gigabit Network Interface Offers...
Product Datasheet - Page 2
...-contrast front-panel LCD provides control settings and critical information to protect connected equipment against damaging surges and line noise. Versatile Installation Options You can also adapt it ... runtime for critical loads. Specifications
OVERVIEW UPC Code UPS Type
743172105455 On-Line
INPUT
Rated input current (Maximum Load) 12.5A
Nominal Input Voltage(s) Supported 100V AC; 110V AC;...