ENGISH Installation and user manual 5P750RC 5P1000RC 5P1500RC Copyright © 2015 EATON All rights reserved. 5P 750VA -1.5 KVA EU_EN Page 1
ENGISH Installation and user manual 5P750RC 5P1000RC 5P1500RC Copyright © 2015 EATON All rights reserved. 5P 750VA -1.5 KVA EU_EN Page 1
Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and User Manual
Page 2
...test requirements . Observe the warning associated with a CE mark. Important instructions that you to important information: RISK OF ELECTRIC SHOCK - For proper disposal, contact your local recycling/reuse or hazardous waste center. Information, advice, help. 5P 750VA-1.5 KVA US_EN Page 2 Do not discard the UPS or the UPS batteries in this manual...rue Blaise Pascal - 38330 Montbonnot Saint Martin - For copies of the EC Declaration of Conformity, contact Eaton Power Quality or check Eaton website: www.powerquality.eaton.com Class B emission level CISPR 22(EN 55022) Harmonics ...
...test requirements . Observe the warning associated with a CE mark. Important instructions that you to important information: RISK OF ELECTRIC SHOCK - For proper disposal, contact your local recycling/reuse or hazardous waste center. Information, advice, help. 5P 750VA-1.5 KVA US_EN Page 2 Do not discard the UPS or the UPS batteries in this manual...rue Blaise Pascal - 38330 Montbonnot Saint Martin - For copies of the EC Declaration of Conformity, contact Eaton Power Quality or check Eaton website: www.powerquality.eaton.com Class B emission level CISPR 22(EN 55022) Harmonics ...
Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and User Manual
Page 3
...batteries or battery packs. - when replacing batteries, replace with the UPS to contact your AC powered system and to the actual electrical consumption of batteries in a computer room. This charges the battery, thus avoiding possible irreversible damage. • During the replacement of 24 hours, at least two people (unpacking, installation... prior to installation, storage must be disconnected from the AC power source. • Dangerous voltage levels are present within the system. Product Safety • The UPS connection instructions and operation described in the manual must be ...
...batteries or battery packs. - when replacing batteries, replace with the UPS to contact your AC powered system and to the actual electrical consumption of batteries in a computer room. This charges the battery, thus avoiding possible irreversible damage. • During the replacement of 24 hours, at least two people (unpacking, installation... prior to installation, storage must be disconnected from the AC power source. • Dangerous voltage levels are present within the system. Product Safety • The UPS connection instructions and operation described in the manual must be ...
Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and User Manual
Page 4
1. Maintenance 19 5.1 Troubleshooting 19 5.2 Battery-module replacement 20 6. Presentation 6 2.1 Standard installations 6 2.2 Rear panel 7 2.3 Control panel 8 2.4 LCD description 9 2.6 User settings 10 3. Appendices 21 6.1 Technical specifications 21 6.2 Glossary 22 5P 750VA-1.5 KVA US_EN Page 4 Installation 12 3.1 Unpacking and contents check 12 3.2 Battery module connection 13 3.3 Rack installation 14 3.4 Wall mounting of AC Input Power 18 4.6 UPS remote control functions 18 5. Operation 17 4.1 Start-up...
1. Maintenance 19 5.1 Troubleshooting 19 5.2 Battery-module replacement 20 6. Presentation 6 2.1 Standard installations 6 2.2 Rear panel 7 2.3 Control panel 8 2.4 LCD description 9 2.6 User settings 10 3. Appendices 21 6.1 Technical specifications 21 6.2 Glossary 22 5P 750VA-1.5 KVA US_EN Page 4 Installation 12 3.1 Unpacking and contents check 12 3.2 Battery module connection 13 3.3 Rack installation 14 3.4 Wall mounting of AC Input Power 18 4.6 UPS remote control functions 18 5. Operation 17 4.1 Start-up...
Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and User Manual
Page 5
...destruction must be removed to visit our web site at www.eaton.com/powerquality or contact your UPS (Uninterruptible Power System). Battery The product contains lead-acid batteries that you to comply with regulations and in 01 the symbols PET 01 02 03 04 05 06 Follow all...PP PS Number in view of their service life. The battery may be transported to read the booklet presenting the safety instructions. 1. Then follow the indications in compliance with the utmost care. Product The product is made of their service life in this manual to take the time to a ...
...destruction must be removed to visit our web site at www.eaton.com/powerquality or contact your UPS (Uninterruptible Power System). Battery The product contains lead-acid batteries that you to comply with regulations and in 01 the symbols PET 01 02 03 04 05 06 Follow all...PP PS Number in view of their service life. The battery may be transported to read the booklet presenting the safety instructions. 1. Then follow the indications in compliance with the utmost care. Product The product is made of their service life in this manual to take the time to a ...
Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and User Manual
Page 8
On The UPS has an active alarm or fault. shooting in section 5.1 for additional information. 5P 750VA-1.5 KVA US_EN Page 8 ENGLISH 2.3 Control panel The UPS has a five-button graphical LCD. It provides useful information about the UPS itself, load status, events, measurements and settings. 100% 19min 1EBM The following table shows the indicator status and description: Indicator Green Status Description On The UPS is operating normally Orange Red On The UPS is on Battery mode. See trouble-
On The UPS has an active alarm or fault. shooting in section 5.1 for additional information. 5P 750VA-1.5 KVA US_EN Page 8 ENGLISH 2.3 Control panel The UPS has a five-button graphical LCD. It provides useful information about the UPS itself, load status, events, measurements and settings. 100% 19min 1EBM The following table shows the indicator status and description: Indicator Green Status Description On The UPS is operating normally Orange Red On The UPS is on Battery mode. See trouble-
Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and User Manual
Page 9
...9 The equipment is pressed. Prepare your equipment for start- Description Equipment is not powered until button is still normally protected. Online mode The UPS is outside normal mode thresholds. Battery LED is on 1 beep every 10 seconds End of inactivity. Depending on section 5.1 ... troubleshooting on the UPS Load, the "Battery Low" warning may vary significantly. up command from user. In AVR mode 1 beep every 10 seconds On Battery The UPS is operating normally but the utility voltage is operating normally. The UPS is powering the equipment with the battery power....
...9 The equipment is pressed. Prepare your equipment for start- Description Equipment is not powered until button is still normally protected. Online mode The UPS is outside normal mode thresholds. Battery LED is on 1 beep every 10 seconds End of inactivity. Depending on section 5.1 ... troubleshooting on the UPS Load, the "Battery Low" warning may vary significantly. up command from user. In AVR mode 1 beep every 10 seconds On Battery The UPS is operating normally but the utility voltage is operating normally. The UPS is powering the equipment with the battery power....
Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and User Manual
Page 10
... power usage measurements Settings Fault log Identification Local settings In/Out settings On/Off settings Battery settings Fault list Reset fault list Sets product general parameters Sets Input and Output parameters Sets On/Off conditions Sets battery configuration Displays the faults stored Clears faults UPS Type / Part Number / Serial Number / Firmware release / Com card address 2.6 User settings The following table displays the options that can be changed...
... power usage measurements Settings Fault log Identification Local settings In/Out settings On/Off settings Battery settings Fault list Reset fault list Sets product general parameters Sets Input and Output parameters Sets On/Off conditions Sets battery configuration Displays the faults stored Clears faults UPS Type / Part Number / Serial Number / Firmware release / Com card address 2.6 User settings The following table displays the options that can be changed...
Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and User Manual
Page 11
... week(in constant charge, otherwise following ABM battery test method) 20 % 0% Battery charge mode [ABM cycling] [Constant charge] ABM cycling External battery [Auto detection] [Manual EBM set.] [Manual battery set.] Deep discharge protection [Yes] [No] If set , automatic restart will occur immediately. [Disable] [Enable] Enables the product to Yes, the UPS automatically prevents battery from software are authorised. If enabled, LCD and communication...
... week(in constant charge, otherwise following ABM battery test method) 20 % 0% Battery charge mode [ABM cycling] [Constant charge] ABM cycling External battery [Auto detection] [Manual EBM set.] [Manual battery set.] Deep discharge protection [Yes] [No] If set , automatic restart will occur immediately. [Disable] [Enable] Enables the product to Yes, the UPS automatically prevents battery from software are authorised. If enabled, LCD and communication...
Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and User Manual
Page 16
... RS232 and USB communication ports can now communicate with the 2 screws. • Pins 1, 3, 4, 5, 6, 10: not used • Pin 2: common (user) • Pin 7: low battery • Pin 8: operation on battery power • Pin 9: UPS ON, equipment supplied n.o.: normally open contact When a signal is activated, the contact is not necessary to shut down the UPS before installing a communication...
... RS232 and USB communication ports can now communicate with the 2 screws. • Pins 1, 3, 4, 5, 6, 10: not used • Pin 2: common (user) • Pin 7: low battery • Pin 8: operation on battery power • Pin 9: UPS ON, equipment supplied n.o.: normally open contact When a signal is activated, the contact is not necessary to shut down the UPS before installing a communication...
Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and User Manual
Page 17
... the UPS when AC input power is operating normally and any loads are supplied by the battery. • The and indicator illuminates solid. • The audio alarm beeps every ten seconds. The UPS cycles through Standby mode to be in . 2. The UPS then transfers to Standby mode, and the indicator turns off. 4.4 Operation on the UPS...
... the UPS when AC input power is operating normally and any loads are supplied by the battery. • The and indicator illuminates solid. • The audio alarm beeps every ten seconds. The UPS cycles through Standby mode to be in . 2. The UPS then transfers to Standby mode, and the indicator turns off. 4.4 Operation on the UPS...
Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and User Manual
Page 18
Shut down the UPS. Restarting the UPS requires manual intervention. • ROO: Remote ON/OFF allows remote ... (UPS connected to AC power and AC power is supplied again. 4.6 UPS remote control functions The 5P offers a choice between the two pins of the UPS (see diagram). ⑧ Contact open : UPS shutdown, LED goes ON. Warning. Activate... • RPO: Remote Power Off allows a remote contact to be connected to test the function. End of battery backup time • LCD displays "End of backup time". • All the LEDs go OFF. • The audio alarms stops. 4.5 Return of ...
Shut down the UPS. Restarting the UPS requires manual intervention. • ROO: Remote ON/OFF allows remote ... (UPS connected to AC power and AC power is supplied again. 4.6 UPS remote control functions The 5P offers a choice between the two pins of the UPS (see diagram). ⑧ Contact open : UPS shutdown, LED goes ON. Warning. Activate... • RPO: Remote Power Off allows a remote contact to be connected to test the function. End of battery backup time • LCD displays "End of backup time". • All the LEDs go OFF. • The audio alarms stops. 4.5 Return of ...
Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and User Manual
Page 19
... an internal fault. Remove some of the battery life is reached. The alarm resets when the condition becomes inactive. Contact your service representative Verify that all batteries are properly connected. 5. Note. Maintenance 5.1 Troubleshooting Operation status Batteries disconnected Overload Possible cause The UPS does not recognize the internal batteries The batteries are disconnected Power requirements exceeds the UPS capacity (greater...
... an internal fault. Remove some of the battery life is reached. The alarm resets when the condition becomes inactive. Contact your service representative Verify that all batteries are properly connected. 5. Note. Maintenance 5.1 Troubleshooting Operation status Batteries disconnected Overload Possible cause The UPS does not recognize the internal batteries The batteries are disconnected Power requirements exceeds the UPS capacity (greater...
Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and User Manual
Page 20
... are required before servicing the battery components: • remove watches, rings, bracelets and all other metal objects from the hands and arms, • use only batteries supplied by separating the two connectors ○C D. 5.2 Battery-module replacement Safety recommendations The battery can cause electrocution ...battery module by EATON. • Take care to firmly press together the two parts of the connector during remounting. 5P 750VA-1.5 KVA US_EN Page 20 Remove the battery module and replace it ○E Mounting the new battery module Carry out the above instructions...
... are required before servicing the battery components: • remove watches, rings, bracelets and all other metal objects from the hands and arms, • use only batteries supplied by separating the two connectors ○C D. 5.2 Battery-module replacement Safety recommendations The battery can cause electrocution ...battery module by EATON. • Take care to firmly press together the two parts of the connector during remounting. 5P 750VA-1.5 KVA US_EN Page 20 Remove the battery module and replace it ○E Mounting the new battery module Carry out the above instructions...
Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and User Manual
Page 21
6. Appendices 6.1 Technical specifications Rack Output Power @ 120 V Output Power @ 100 V Output Power @ 125 V Rated input voltage Input voltage range Input frequency range Voltage Frequency Battery (sealed lead acid, maintenance free) Operating temperature range Storage temperature range Relative humidity Noise level 5P750RC 5P1000RC 750... W 625 VA 500 W 833VA 641W 750 VA 600 W 1000 VA 770 W AC Input power Single phase 100-125 V 89 to 151 V (1) 47 to 70 Hz (50 Hz system), 56.5 to 70 Hz (60 Hz system) (2) Output on battery power 120 V (-10/+6 %) (3) 50/60 Hz ±0.1 Hz 2 x 12 V 7.2 ...
6. Appendices 6.1 Technical specifications Rack Output Power @ 120 V Output Power @ 100 V Output Power @ 125 V Rated input voltage Input voltage range Input frequency range Voltage Frequency Battery (sealed lead acid, maintenance free) Operating temperature range Storage temperature range Relative humidity Noise level 5P750RC 5P1000RC 750... W 625 VA 500 W 833VA 641W 750 VA 600 W 1000 VA 770 W AC Input power Single phase 100-125 V 89 to 151 V (1) 47 to 70 Hz (50 Hz system), 56.5 to 70 Hz (60 Hz system) (2) Output on battery power 120 V (-10/+6 %) (3) 50/60 Hz ±0.1 Hz 2 x 12 V 7.2 ...
Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and User Manual
Page 22
... operating on battery power alone. 6.2 Glossary Backup time Battery test Cold start Deep discharge Load Low-battery warning Normal AC input Percent load Personalisation Programmable Outlets UPS UPS ON/OFF controlled by software Time during which the load can be supplied by the software to better suit user needs. It is possible to modify certain UPS parameters set in...
... operating on battery power alone. 6.2 Glossary Backup time Battery test Cold start Deep discharge Load Low-battery warning Normal AC input Percent load Personalisation Programmable Outlets UPS UPS ON/OFF controlled by software Time during which the load can be supplied by the software to better suit user needs. It is possible to modify certain UPS parameters set in...
Product Datasheet
Page 1
... down to protect devices q Exclusive ABM technology with 10 Outlets q USB cable q RS-232 cable q Mounting hardware q Quick Start Guide UPS firmware can also be flashed remotely through short power failures and give you shed non-critical loads to provide advanced notice when batteries need replacing. An optional Environmental Monitoring Probe Gen 2 (EMPDT1H1C2, sold separately) enables...
... down to protect devices q Exclusive ABM technology with 10 Outlets q USB cable q RS-232 cable q Mounting hardware q Quick Start Guide UPS firmware can also be flashed remotely through short power failures and give you shed non-critical loads to provide advanced notice when batteries need replacing. An optional Environmental Monitoring Probe Gen 2 (EMPDT1H1C2, sold separately) enables...
Product Datasheet
Page 2
...Installation Options You can be programmed through the LCD to provide reliable communications to a serial-enabled or USB-enabled device for cabling and enhanced airflow through the rack. Specifications OVERVIEW UPC Code UPS Type 743172088284 Line-Interactive INPUT Nominal Input Voltage(s) Supported... Capacity (VA) Output Capacity (kVA) Output Capacity (Watts) Output Capacity (kW) Power Factor Nominal Voltage Details Frequency Compatibility Load Management Receptacles Output AC Waveform (AC Mode) Output AC Waveform (Battery Mode) 1440 1.44 1100 1.1 0.76 100V, 120V, 125V 50 / 60 Hz Two...
...Installation Options You can be programmed through the LCD to provide reliable communications to a serial-enabled or USB-enabled device for cabling and enhanced airflow through the rack. Specifications OVERVIEW UPC Code UPS Type 743172088284 Line-Interactive INPUT Nominal Input Voltage(s) Supported... Capacity (VA) Output Capacity (kVA) Output Capacity (Watts) Output Capacity (kW) Power Factor Nominal Voltage Details Frequency Compatibility Load Management Receptacles Output AC Waveform (AC Mode) Output AC Waveform (Battery Mode) 1440 1.44 1100 1.1 0.76 100V, 120V, 125V 50 / 60 Hz Two...
Product Datasheet
Page 3
... (3-stage charging extends battery service life by 50% and provides advance warning for battery replacement) USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display LCD graphical display Switches RPO / ROO Alarm Cancel Operation Press ESC to silence the alarm Audible Alarm Audible alarm indicates utility failure, low-battery, overload, other UPS/Battery fault or remote shutdown conditions LED Indicators 3 status-indicating LEDs SURGE / NOISE...
... (3-stage charging extends battery service life by 50% and provides advance warning for battery replacement) USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display LCD graphical display Switches RPO / ROO Alarm Cancel Operation Press ESC to silence the alarm Audible Alarm Audible alarm indicates utility failure, low-battery, overload, other UPS/Battery fault or remote shutdown conditions LED Indicators 3 status-indicating LEDs SURGE / NOISE...
Product Datasheet
Page 4
...); RoHS; FCC Part 15 Class B (USA) WARRANTY & SUPPORT Product Warranty Period (U.S. & Canada) Extended Service Plans 3-year limited warranty ADVANCED DEPOT EXCHANGE5-YEAR DEPOT REPAIR: 5SW5Y-1750UCExpedited parts coverage for 5 yearsParts, electronics and UPS batteries coverageNext business day ...support © 2022 Eaton. UL 1778; IEC 62040-2; All other trademarks are the property of their respective owners. 4 / 4 Hot swappable batteries; EN 55024; Network Card Optional RS-232; USB FEATURES & SPECIFICATIONS High Availability UPS Features Automatic Voltage Regulation (AVR...
...); RoHS; FCC Part 15 Class B (USA) WARRANTY & SUPPORT Product Warranty Period (U.S. & Canada) Extended Service Plans 3-year limited warranty ADVANCED DEPOT EXCHANGE5-YEAR DEPOT REPAIR: 5SW5Y-1750UCExpedited parts coverage for 5 yearsParts, electronics and UPS batteries coverageNext business day ...support © 2022 Eaton. UL 1778; IEC 62040-2; All other trademarks are the property of their respective owners. 4 / 4 Hot swappable batteries; EN 55024; Network Card Optional RS-232; USB FEATURES & SPECIFICATIONS High Availability UPS Features Automatic Voltage Regulation (AVR...