Tripp Lite 0SU70033 Support and Manuals

Get Help and Manuals for this Tripp Lite item

View All Support Options Below
Free Tripp Lite 0SU70033 manuals!
Problems with Tripp Lite 0SU70033?

Ask a Question

Popular Tripp Lite 0SU70033 Manual Pages

Quick Start Guide for for 0SU7033 KVM Switch 933210 - Page 1

... read the softcopy User Guide after performing the Quick Start procedure. All rights reserved. PX Serial - The PX Serial components The package includes:  1 PX Serial unit  1 Power adapter (100-240VAC)  Mounting kit foot pads  Minicom CD 1111 W. 35th Street, Chicago, IL 60609 USA www.tripplite.com/support Copyright ©2012 Tripp Lite.
Quick Start Guide for for 0SU7033 KVM Switch 933210 - Page 3

... Mbps Ethernet connection. Serial port is off , or power error condition exists. Power is receiving data. Blinking: 100 Mbps Ethernet connection. Ethernet cable is disconnected, or has a short. Ethernet cable is disconnected, or has a short. Connecting the PX Serial Connect the PX Serial to the power supply, the Network switch and Serial device as explained...
Quick Start Guide for for 0SU7033 KVM Switch 933210 - Page 4

... the unit is ready and if the IP setting is running correctly, the LED turns green. 5.1.2 Power Jack (PWR2) Connect the supplied 12VDC power adapter, or 24VDC power input to the network switch via the LAN 1 or LAN 2 port using a standard 10/100M Ethernet cable. The Ethernet interface supports auto MDI/MDIX. But if when the...
Owner's Manual for 0SU7033 KVM Switch 933209 - Page 1

PX Serial User Guide 1111 W. 35th Street, Chicago, IL 60609 USA www.tripplite.com/support Copyright ©2012 Tripp Lite. All rights reserved.
Owner's Manual for 0SU7033 KVM Switch 933209 - Page 2

... 1 Port Configuration 11 10.1 Serial Setting ...11 10.2 Port Profile...12 10.3 Service Mode...13 11. Mounting the PX Serial 5 7. Configuring the PX Serial unit 8 9.1 Basic settings ...9 9.2 Network Setting ...10 9.3 Change password...10 10. Technical specifications 27 19. Introduction ...3 2.1 Integration into the KVM.net system 23 16.1 Installing the script on the KVM.net...
Owner's Manual for 0SU7033 KVM Switch 933209 - Page 3

... protection against such interference when operating the equipment in accordance with Part 15, Subpart J of Minicom Advanced Systems Limited. This system is subject to operate the equipment. Technical precautions This equipment generates radio frequency energy and if not installed in a commercial environment. Minicom Advanced Systems Limited assumes no responsibility for any errors...
Owner's Manual for 0SU7033 KVM Switch 933209 - Page 4

...23 explains how to facilitate an intuitively manageable, centralized out-of each device. It supports hundreds of KVM IP devices. KVM.net is a robust central management appliance that ...; 1 PX Serial unit  1 Power adapter (100-240VAC)  Mounting kit foot pads  Minicom CD 3 Additional management features include SNMP support and email alerts. 2.1 Integration into KVM.net...
Owner's Manual for 0SU7033 KVM Switch 933209 - Page 6

... switch and Serial device as explained below. 7.1 Connecting the Power supply You can connect the PX Serial to mount the ears on and booting up . Blinking: Indicates an IP conflict, or DHCP or BOOTP server did not respond properly On: Power 2 is off , or power error condition exists. Blinking: Located by Administrator's Location function. Blinking...
Owner's Manual for 0SU7033 KVM Switch 933209 - Page 7

...supports auto MDI/MDIX. Tighten the terminal screws to different switches. Power 2 LED turns red to the network switch via the LAN 1 or LAN 2 port using a standard 10/100M Ethernet cable. When the unit is ready and if the IP setting is running correctly, the LED turns green. 7.1.2 Power Jack (PWR2) Connect the supplied 12VDC power...port. 6 USER GUIDE 7.1.1 Terminal Block (PWR1) 1. see...
Owner's Manual for 0SU7033 KVM Switch 933209 - Page 8

... IP address (192.168.10.2), and password protection (if activated) is ready to function. 7 it will cause errors! 120 Ohm termination for long distance 2-wire RS485 (Default) No termination for RS422 / 4-wire RS485 / 2-wire RS485. for long distance 4-wire RS485 / RS422 Don't use this setting - When the Power LED turns green, the device is removed...
Owner's Manual for 0SU7033 KVM Switch 933209 - Page 11

... For dynamic IP address reporting at defined time intervals, fill in the Auto IP report fields. 9.3 Change password By default access to the web configuration interface is not password protected. Figure 5 Network Setting On this page you configure for the network settings. 9.2 Network Setting USER GUIDE Consult your Network Administrator for the PX:  IP Configuration -
Owner's Manual for 0SU7033 KVM Switch 933209 - Page 14

...port is free to try connecting with other hosts. Zero, disables this setting (default). 10.3 Service Mode PX SERIAL Click Service Mode, the following appears. Idle Timeout: When the serial port stops data transmission... for other hosts. Figure 9 Service Mode In TCP Server mode, you must define the available port number, idle timeout,...
Owner's Manual for 0SU7033 KVM Switch 933209 - Page 17

...the modem connection status has changed : When DSR (Data Set Ready) signal changes, indicating that the data communication equipment is powered off, the event will be triggered. Figure 12 Device ...will be notified by means of notification - 11.3 Event Notification USER GUIDE Click Event Notification, the following appears. RI changed : When CTS (Clear To Send) signal changes...
Owner's Manual for 0SU7033 KVM Switch 933209 - Page 18

... Firmware: Upgrade to select the firmware then click Upgrade command. 13. Configuring the PX via an SSH client. Export Configuration: Save the current configuration into a file and save any configuration changes, click Submit. 12.1 Maintenance Click Maintenance, the following : Load Factory Default: Load default configuration except Network Settings. There are many SSH clients, for example...
Owner's Manual for 0SU7033 KVM Switch 933209 - Page 28

... Rx-,GND Data+, Data-,GND XON/XOFF, RTS/CTS, DTR/DSR 15KV ESD Power Requirements Power Input Power Line protection PWR1: 12~48VDC in 1.5 KV magnetic isolation ICMP, IP, TCP, UDP, DHCP... Flow Control Serial Line Protection RS232, RS422, 2/4-Wire RS485 male DB9 110 bps to 185°F) 27 Technical specifications Network Interface Ethernet Ethernet connector Protection Protocols 2 x 10/...

Tripp Lite 0SU70033 Reviews

Do you have an experience with the Tripp Lite 0SU70033 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Tripp Lite yet.

Popular Tripp Lite 0SU70033 Search Terms

The following terms are frequently used to search for Tripp Lite 0SU70033 support:

Ask a New Question
Use the box below to post a new question about Tripp Lite 0SU70033.
Manuals / Documents
Download any of our Tripp Lite 0SU70033 manuals for free!

We have the following 2 documents available for the Tripp Lite 0SU70033:
  • Owner's Manual for 0SU7033 KVM Switch 933209
  • Quick Start Guide for for 0SU7033 KVM Switch 933210

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Tripp Lite Manuals

Find free Tripp Lite 0SU70033 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Tripp Lite Reviews

View thousands of Tripp Lite 0SU70033 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Tripp Lite customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Tripp Lite customer service rankings, employee comments and much more from our sister site.