Design Guide - Ventilation
Page 3
... width of the hood should equal that of the cooktop or rangetop or exceed it by 3 inches on either side. Install these hoods only with Thermador blowers. *High heat tested to accommodate Pro Harmony™ or Pro Rangetop 18,000 burners and grill. 134
... width of the hood should equal that of the cooktop or rangetop or exceed it by 3 inches on either side. Install these hoods only with Thermador blowers. *High heat tested to accommodate Pro Harmony™ or Pro Rangetop 18,000 burners and grill. 134
Design Guide - Ventilation
Page 5
install these hoods only with Thermador blowers. 136 VENTILATION COOKTOP AND VENTILATION MATRIX MASTERPIECE® SERIES = PErFECT FIT = VIABLE OPTION 30" HMWB30FS WALL HOODS WITH BLOWEr 36" HMWB36FS 30" HMWN30FS WALL HOODS 36" HMWN36FS 48" HMWN48FS 36" HMCB36FS CHIMNEY HOODS WITH BLOWEr 42" HMCB42FS CHIMNEY HOODS 36" HMCN36FS 42" HMCN42FS 30-INCH INDuCTION DrAWEr HOOD...
install these hoods only with Thermador blowers. 136 VENTILATION COOKTOP AND VENTILATION MATRIX MASTERPIECE® SERIES = PErFECT FIT = VIABLE OPTION 30" HMWB30FS WALL HOODS WITH BLOWEr 36" HMWB36FS 30" HMWN30FS WALL HOODS 36" HMWN36FS 48" HMWN48FS 36" HMCB36FS CHIMNEY HOODS WITH BLOWEr 42" HMCB42FS CHIMNEY HOODS 36" HMCN36FS 42" HMCN42FS 30-INCH INDuCTION DrAWEr HOOD...
Design Guide - Ventilation
Page 7
...36", 42", 48", 54" HPWB_FS HNI_YS 30" 36", 48" 42", 48", 54" CUSTOM INSERTS VC12_DS 30", 36", 48" Blower CFM remote Inline Integral 600 • VTN630C 4.8 1000 • VTN1030C 5.0 600 • VTR630D 4.3 1000 • VTR1030D 7.8 1300 • VTR1330E 9.2 600 • ... VTI610D 5.8 1000 • VTI1010D 7.6 *Purchase separately at most hardware stores, unless otherwise indicated with a Thermador model number. 138 PROFESSIONAL SERIES Type Model No. VENTILATION BLOWER SELECTION AND DUCT GUIDE Total Amps @ 120 Volts, 60 Hz Type Information Model No.
...36", 42", 48", 54" HPWB_FS HNI_YS 30" 36", 48" 42", 48", 54" CUSTOM INSERTS VC12_DS 30", 36", 48" Blower CFM remote Inline Integral 600 • VTN630C 4.8 1000 • VTN1030C 5.0 600 • VTR630D 4.3 1000 • VTR1030D 7.8 1300 • VTR1330E 9.2 600 • ... VTI610D 5.8 1000 • VTI1010D 7.6 *Purchase separately at most hardware stores, unless otherwise indicated with a Thermador model number. 138 PROFESSIONAL SERIES Type Model No. VENTILATION BLOWER SELECTION AND DUCT GUIDE Total Amps @ 120 Volts, 60 Hz Type Information Model No.
Design Guide - Ventilation
Page 8
... AND DUCT GUIDE roof plate required Duct Size at Blower Transition with Backdraft Damper Duct Size at Discharge Discharge Direction rFPLT600 rFPLT1000 6-Inch 8-Inch 10-Inch IHncoloudd Iendformation required* 6-Inch 8-Inch 10-Inch Vertical Horizontal ...; • • • • • • • • • • • • CV2T6 • • CV2T6 • CV2T6 • • CV2T6 • 1.800.735.4328 | THERMADOR.COM • 36"only • • • • • • • 139
... AND DUCT GUIDE roof plate required Duct Size at Blower Transition with Backdraft Damper Duct Size at Discharge Discharge Direction rFPLT600 rFPLT1000 6-Inch 8-Inch 10-Inch IHncoloudd Iendformation required* 6-Inch 8-Inch 10-Inch Vertical Horizontal ...; • • • • • • • • • • • • CV2T6 • • CV2T6 • CV2T6 • • CV2T6 • 1.800.735.4328 | THERMADOR.COM • 36"only • • • • • • • 139
Design Guide - Ventilation
Page 9
VENTILATION BLOWER OPTIONS INTEGRAL (MOUNTED ON hOOD) vTn600Cv2C - 600 CFM vTn600F - 600 CFM vTn1080F - 1000 CFM vTn1000F - 1200 CFM vTn630C - 600 CFM 83/4" 81/4" 25" vTn1030C - 1000 CFM 81/4" 25" REMOTE (MOUNTED TO ROOF OR EXTERNAL WALL) vTR630D - 600 CFM vTR1030D - 1000 CFM vTR1330E - 1300 CFM INLINE (MOUNTED BETWEEN KITChEN AND EXTERNAL WALL) vTi610D - 600 CFM vTi1010D - 1000 CFM 140
VENTILATION BLOWER OPTIONS INTEGRAL (MOUNTED ON hOOD) vTn600Cv2C - 600 CFM vTn600F - 600 CFM vTn1080F - 1000 CFM vTn1000F - 1200 CFM vTn630C - 600 CFM 83/4" 81/4" 25" vTn1030C - 1000 CFM 81/4" 25" REMOTE (MOUNTED TO ROOF OR EXTERNAL WALL) vTR630D - 600 CFM vTR1030D - 1000 CFM vTR1330E - 1300 CFM INLINE (MOUNTED BETWEEN KITChEN AND EXTERNAL WALL) vTi610D - 600 CFM vTi1010D - 1000 CFM 140
Design Guide - Ventilation
Page 10
...8226; Halogen lighting • Dishwasher safe, stainless steel frame filters • Automatic "Time-to-Clean-Filter" reminder light ISLAND HOODS Thermador island hoods offer excellent overall efficiency in drawing away smoke, moisture and heat. • An option for when a wall surface ...sleek look for non-professional cooktops. • Over 13-inch intake • Full face filter combines a filter with integral blower is available for difficult-to -remove, dishwasher safe element • Wall or island applications • 600 CFM recirculation kit option ...
...8226; Halogen lighting • Dishwasher safe, stainless steel frame filters • Automatic "Time-to-Clean-Filter" reminder light ISLAND HOODS Thermador island hoods offer excellent overall efficiency in drawing away smoke, moisture and heat. • An option for when a wall surface ...sleek look for non-professional cooktops. • Over 13-inch intake • Full face filter combines a filter with integral blower is available for difficult-to -remove, dishwasher safe element • Wall or island applications • 600 CFM recirculation kit option ...
Design Guide - Ventilation
Page 13
...HMWN30FS, HMWN36FS, HMWN48FS 15 or 20 Amp HMWB30FS, HMWB36FS 15 or 20 Amp Install a suitable conduit box (not furnished). Remote blowers require a five wire installation. Select Professional Series for the ultimate in this design guide. 144 ELECTRICAL SPECIFICATIONS Be sure your... models include delayed shut-off to the junction box. WALL HOODS FEATURES & BENEFITS HALOgEN LIgHTS Bright halogen lighting spotlights your Thermador Wall Hood is properly installed and grounded by a qualified technician. An appropriately-sized, UL-listed conduit connector must...
...HMWN30FS, HMWN36FS, HMWN48FS 15 or 20 Amp HMWB30FS, HMWB36FS 15 or 20 Amp Install a suitable conduit box (not furnished). Remote blowers require a five wire installation. Select Professional Series for the ultimate in this design guide. 144 ELECTRICAL SPECIFICATIONS Be sure your... models include delayed shut-off to the junction box. WALL HOODS FEATURES & BENEFITS HALOgEN LIgHTS Bright halogen lighting spotlights your Thermador Wall Hood is properly installed and grounded by a qualified technician. An appropriately-sized, UL-listed conduit connector must...
Design Guide - Ventilation
Page 14
...If using ducted ventilation systems greater than the width of duct. Thermador Wall Hoods may require additional CFM. Remote Blowers (VTR Series) Depending on your client. • More demanding cooks usually require more powerful blower. Use a qualified and trained installer. An exterior ...installation may require the use of make-up air systems when using a 10" duct, Thermador recommends not exceeding 150 feet of the cooking surface. ...
...If using ducted ventilation systems greater than the width of duct. Thermador Wall Hoods may require additional CFM. Remote Blowers (VTR Series) Depending on your client. • More demanding cooks usually require more powerful blower. Use a qualified and trained installer. An exterior ...installation may require the use of make-up air systems when using a 10" duct, Thermador recommends not exceeding 150 feet of the cooking surface. ...
Design Guide - Ventilation
Page 15
...Cable length: 30 ft. Convenient shelf allows dishes to the Pro Grand® professional range CONVENIENCE - Welded, polished seams for up to blower and hood controls - DC__US - 6-Inch High Duct Cover DCT__US - 12-Inch High Duct Cover For use with PH_CS - Includes stainless ...steel backguard and two shelves. 146 See Blower Options Table 10" Round Vertical or Horizontal Commercial-Style Baffle 30", 36", 42" - 2 Bulbs 48", 54" - 3 Bulbs 2 PERFORmANCE - ...
...Cable length: 30 ft. Convenient shelf allows dishes to the Pro Grand® professional range CONVENIENCE - Welded, polished seams for up to blower and hood controls - DC__US - 6-Inch High Duct Cover DCT__US - 12-Inch High Duct Cover For use with PH_CS - Includes stainless ...steel backguard and two shelves. 146 See Blower Options Table 10" Round Vertical or Horizontal Commercial-Style Baffle 30", 36", 42" - 2 Bulbs 48", 54" - 3 Bulbs 2 PERFORmANCE - ...
Design Guide - Ventilation
Page 16
... or external wall) VTR630D 600 CFM VTR1030D 1000 CFM VTR1330E 1300 CFM INTEgRAL (mounted on hood) VTN630C 600 CFM 83/4" VTN1030C 1000 CFM 81/4" 81/4" 25" 25" REmOTE BLOWER ACCESSORIES RFPLT600, RFPLT1000 - Hood installation height above a Thermador Professional Cooktop or Range, consult the appliance's installation manual. Both vertical and horizontal discharge is shipped...
... or external wall) VTR630D 600 CFM VTR1030D 1000 CFM VTR1330E 1300 CFM INTEgRAL (mounted on hood) VTN630C 600 CFM 83/4" VTN1030C 1000 CFM 81/4" 81/4" 25" 25" REmOTE BLOWER ACCESSORIES RFPLT600, RFPLT1000 - Hood installation height above a Thermador Professional Cooktop or Range, consult the appliance's installation manual. Both vertical and horizontal discharge is shipped...
Design Guide - Ventilation
Page 17
... HPWB36FS - 36-Inch HPWB48FS - 48-Inch SPECIFICATIONS Available Hood Widths 30", 36", 48" Blower 30" - 600 CFM Blower Included 36" - 1200 CFM Blower Included 48" - 1200 CFM Blower Included Duct Size at capturing grease - Welded, polished seams for hard to 10 minutes - ...off tackles lingering odors for up to duct installations - Stainless steel finish - Perfect for a flawless design - Integrated Blower included - Hood includes filters, backdraft damper and transition - Recirculation possible with Recirculation Kit 148 Dishwasher safe low-profile...
... HPWB36FS - 36-Inch HPWB48FS - 48-Inch SPECIFICATIONS Available Hood Widths 30", 36", 48" Blower 30" - 600 CFM Blower Included 36" - 1200 CFM Blower Included 48" - 1200 CFM Blower Included Duct Size at capturing grease - Welded, polished seams for hard to 10 minutes - ...off tackles lingering odors for up to duct installations - Stainless steel finish - Perfect for a flawless design - Integrated Blower included - Hood includes filters, backdraft damper and transition - Recirculation possible with Recirculation Kit 148 Dishwasher safe low-profile...
Design Guide - Ventilation
Page 18
... hoods are used for additional specifications. The cabinet must be used to the appropriate section for vertical discharge. This Thermador Wall Hood can vary. Refer to fill the space between the hood and ceiling. WALL HOODS VENTILATION 24-INCH DEPTH WALL... HOOD WITH BLOWER (30"/36"/48") models: HPWB30FS, HPWB36FS, HPWB48FS INSTALLATION OPTIONS Thermador Wall Hoods may be mounted on a wall or suspended from a cabinet. VENTILATION - To obtain the necessary ...
... hoods are used for additional specifications. The cabinet must be used to the appropriate section for vertical discharge. This Thermador Wall Hood can vary. Refer to fill the space between the hood and ceiling. WALL HOODS VENTILATION 24-INCH DEPTH WALL... HOOD WITH BLOWER (30"/36"/48") models: HPWB30FS, HPWB36FS, HPWB48FS INSTALLATION OPTIONS Thermador Wall Hoods may be mounted on a wall or suspended from a cabinet. VENTILATION - To obtain the necessary ...
Design Guide - Ventilation
Page 19
See Blower Options table Duct Size at capturing grease - Classic chiseled design matches Thermador's Masterpiece® Series family of smoke and odor DESIgN - Grease collection trays are highly efficient at Discharge Ducting Direction Dishwasher...light - Stainless steel finish - Use with kit RECIRC__FS (max 600 CFM) CONVENIENCE - For use with Recirculation Kit 150 Recirculation possible with 600 CFM blowers only 4" 12" 30", 36" CHFILT3036 - Replacement Charcoal Filters For use with PH__DS, HPWB__FS, HMWN__FS and HMWB__FS Width 30-Inch 36-Inch 48-Inch ...
See Blower Options table Duct Size at capturing grease - Classic chiseled design matches Thermador's Masterpiece® Series family of smoke and odor DESIgN - Grease collection trays are highly efficient at Discharge Ducting Direction Dishwasher...light - Stainless steel finish - Use with kit RECIRC__FS (max 600 CFM) CONVENIENCE - For use with Recirculation Kit 150 Recirculation possible with 600 CFM blowers only 4" 12" 30", 36" CHFILT3036 - Replacement Charcoal Filters For use with PH__DS, HPWB__FS, HMWN__FS and HMWB__FS Width 30-Inch 36-Inch 48-Inch ...
Design Guide - Ventilation
Page 20
.../or 12" duct covers are not recommended to be used over indoor grills. A B C Duct Size RFPLT600 7 1/2" 8 1/2" 9 1/4" 6" RFPLT1000 9 3/8" 12" 11 1/8" 10" 1.800.735.4328 | THERMADOR.COM 151 VENTILATION - BLOWER OPTIONS REmOTE VTR630D - 600 CFM Use RFPLT600 in roof-mount applications VTR1030D - 1000 CFM Use RFPLT1000 in roof-mount applications VTR1330E - 1300 CFM Use...
.../or 12" duct covers are not recommended to be used over indoor grills. A B C Duct Size RFPLT600 7 1/2" 8 1/2" 9 1/4" 6" RFPLT1000 9 3/8" 12" 11 1/8" 10" 1.800.735.4328 | THERMADOR.COM 151 VENTILATION - BLOWER OPTIONS REmOTE VTR630D - 600 CFM Use RFPLT600 in roof-mount applications VTR1030D - 1000 CFM Use RFPLT1000 in roof-mount applications VTR1330E - 1300 CFM Use...
Design Guide - Ventilation
Page 21
... installations - Halogen lighting spotlights your best recipes - Recirculation Kit (30"/36") RECIRC30FS/RECIRC36FS - Classic chiseled design matches Thermador's Masterpiece® Series family of smoke and odor DESIgN - Recirculation possible with Recirculation Kit 152 Grease collection trays are ... - Perfect for a flawless design - Welded, polished seams for hard to operate control buttons CAPACITY - 600 CFM Integrated Blower included - Replacement Charcoal Filters For use with kit RECIRC__FS (max 600 CFM) CONVENIENCE - Filter systems are easily removed, dishwasher safe...
... installations - Halogen lighting spotlights your best recipes - Recirculation Kit (30"/36") RECIRC30FS/RECIRC36FS - Classic chiseled design matches Thermador's Masterpiece® Series family of smoke and odor DESIgN - Recirculation possible with Recirculation Kit 152 Grease collection trays are ... - Perfect for a flawless design - Welded, polished seams for hard to operate control buttons CAPACITY - 600 CFM Integrated Blower included - Replacement Charcoal Filters For use with kit RECIRC__FS (max 600 CFM) CONVENIENCE - Filter systems are easily removed, dishwasher safe...
Design Guide - Ventilation
Page 22
WALL HOODS VENTILATION WALL HOOD WITH BLOWER (30"/36") Models: HMWB30FS, HMWB36FS INSTALLATION OPTIONS Thermador Wall Hoods may be installed above a cooktop or range can be used to fill the space between the hood and ceiling... to be structurally joined to the wall studs to the appropriate section for vertical discharge. VENTILATION - To obtain the necessary installation height above a Thermador Professional Cooktop or Range, consult the appliance's installation manual. A ductless, recirculation installation is possible with kit RECIRC__FS. Refer to support the weight ...
WALL HOODS VENTILATION WALL HOOD WITH BLOWER (30"/36") Models: HMWB30FS, HMWB36FS INSTALLATION OPTIONS Thermador Wall Hoods may be installed above a cooktop or range can be used to fill the space between the hood and ceiling... to be structurally joined to the wall studs to the appropriate section for vertical discharge. VENTILATION - To obtain the necessary installation height above a Thermador Professional Cooktop or Range, consult the appliance's installation manual. A ductless, recirculation installation is possible with kit RECIRC__FS. Refer to support the weight ...
Design Guide - Ventilation
Page 26
... Please refer to over 10' (or 120"). This extra space can be filled using a 10" duct, Thermador recommends not exceeding 150 feet of interior and exterior blower options (Remote, Inline or Integral) are mounted along the duct line anywhere between 7'6" (or 90") to the installation... cooktop/range model for additional warranty details. 1.800.735.4328 | THERMADOR.COM 157 You should have a blower included, one can vary between the kitchen and the exterior wall. Proper performance is very important. Thermador Chimney Wall Hoods may be moved and the length and location of ...
... Please refer to over 10' (or 120"). This extra space can be filled using a 10" duct, Thermador recommends not exceeding 150 feet of interior and exterior blower options (Remote, Inline or Integral) are mounted along the duct line anywhere between 7'6" (or 90") to the installation... cooktop/range model for additional warranty details. 1.800.735.4328 | THERMADOR.COM 157 You should have a blower included, one can vary between the kitchen and the exterior wall. Proper performance is very important. Thermador Chimney Wall Hoods may be moved and the length and location of ...
Design Guide - Ventilation
Page 27
... filters - adjustable at Discharge Ducting Direction Ceiling Heights Dishwasher Safe Filters Halogen Lighting 8" Round Vertical 8 ft. See Blower Options Table Duct Size at installation - Stainless steel chimney hood extension for those hours after a late meal - Telescopic chimney ...mode - Filters are highly efficient at capturing grease - Built-in Clean Filter Reminder light - Blowers sold separately - Classic chiseled design matches Thermador's Masterpiece® Series family of standard chimney extension 158 Chimney Extension - Welded, polished seams for up...
... filters - adjustable at Discharge Ducting Direction Ceiling Heights Dishwasher Safe Filters Halogen Lighting 8" Round Vertical 8 ft. See Blower Options Table Duct Size at installation - Stainless steel chimney hood extension for those hours after a late meal - Telescopic chimney ...mode - Filters are highly efficient at capturing grease - Built-in Clean Filter Reminder light - Blowers sold separately - Classic chiseled design matches Thermador's Masterpiece® Series family of standard chimney extension 158 Chimney Extension - Welded, polished seams for up...
Design Guide - Ventilation
Page 28
... RFPLT1000 Overall Dimensions A B C Duct Size 7 1/2" 8 1/2" 9 1/4" 6" 9 3/8" 12" 11 1/8" 10" 1.800.735.4328 | THERMADOR.COM 159 To obtain the necessary installation height above a cooktop can vary. Thermador Chimney Wall Hoods must be mounted on hood) VTN1080F 1000 CFM REMOTE BLOWER ACCESSORIES RFPLT600, RFPLT1000 - BLOWER OPTIONS REMOTE VTR630D - 600 CFM Use RFPLT600 in roof-mount applications VTR1030D...
... RFPLT1000 Overall Dimensions A B C Duct Size 7 1/2" 8 1/2" 9 1/4" 6" 9 3/8" 12" 11 1/8" 10" 1.800.735.4328 | THERMADOR.COM 159 To obtain the necessary installation height above a cooktop can vary. Thermador Chimney Wall Hoods must be mounted on hood) VTN1080F 1000 CFM REMOTE BLOWER ACCESSORIES RFPLT600, RFPLT1000 - BLOWER OPTIONS REMOTE VTR630D - 600 CFM Use RFPLT600 in roof-mount applications VTR1030D...
Design Guide - Ventilation
Page 29
Classic chiseled design matches Thermador's Masterpiece® Series family of standard chimney extension 160 Welded, polished seams for up to 12-foot ceiling applications - For use with HMCB__FS, HMCN__FS - ...MASTERPIECE HMCB36FS - 36-Inch HMCB42FS - 42-Inch PERFORMANCE - 3 fan speeds plus 10 minute high-power operation mode - to operate control buttons CAPACITY - 600 CFM Integrated Blower included CONVENIENCE - Stainless steel chimney hood extension for a flawless design - Filters are highly efficient at capturing grease - Powerfully quiet ventilation systems DESIgN...
Classic chiseled design matches Thermador's Masterpiece® Series family of standard chimney extension 160 Welded, polished seams for up to 12-foot ceiling applications - For use with HMCB__FS, HMCN__FS - ...MASTERPIECE HMCB36FS - 36-Inch HMCB42FS - 42-Inch PERFORMANCE - 3 fan speeds plus 10 minute high-power operation mode - to operate control buttons CAPACITY - 600 CFM Integrated Blower included CONVENIENCE - Stainless steel chimney hood extension for a flawless design - Filters are highly efficient at capturing grease - Powerfully quiet ventilation systems DESIgN...