Design Guide - Pro Harmony Ranges
Page 3
...of the same size, which allows the inclusion of more flame distribution than a round burner. 35 ports / 16 3/4" perimeter 28 ports / 10 3/4" perimeter The design of a conventional range or cooktop and over 50% faster than ever before. Perfect for show. And this latest generation features a... maintop have been crafted for easier cleaning than leading competitors. Leading competitors offer only one or two powerful burners. Each and every Thermador Pro Harmony Range features two ExtraLow burners. 18,000 BTU/HR On EVERy BURnER Delivers superior cooking flexibility by adding a ...
...of the same size, which allows the inclusion of more flame distribution than a round burner. 35 ports / 16 3/4" perimeter 28 ports / 10 3/4" perimeter The design of a conventional range or cooktop and over 50% faster than ever before. Perfect for show. And this latest generation features a... maintop have been crafted for easier cleaning than leading competitors. Leading competitors offer only one or two powerful burners. Each and every Thermador Pro Harmony Range features two ExtraLow burners. 18,000 BTU/HR On EVERy BURnER Delivers superior cooking flexibility by adding a ...
Design Guide - Pro Harmony Ranges
Page 5
...12.5 mb) PROPANE GAS REQuiREMENTS: Inlet Connection: 3/4" NPT external, 1/2" NPT internal (Minimum 3/4" diam. flex line.) Supply Pressure: 11" min. MODEL PRG304GH PRL304GH PRG366GH PRL366GH PRG364GDH PRL364GDH REQuiRED ciRcuiT BREAkER 120V AC, 60 Hz 15 Amp 15 Amp 15 Amp 15 Amp 20 Amp 20 Amp important...technician. Dual-fuel models are LP convertible by the appliance. water column. (27.4 mb to 34.9 mb) Manifold Pressure: 10" water column (24.9 mb) DuAL-FuEL: Thermador Pro Harmony Dual-Fuel Ranges are dual rated, designed to be connected to a 120V AC, 60 Hz, single-phase power supply...
...12.5 mb) PROPANE GAS REQuiREMENTS: Inlet Connection: 3/4" NPT external, 1/2" NPT internal (Minimum 3/4" diam. flex line.) Supply Pressure: 11" min. MODEL PRG304GH PRL304GH PRG366GH PRL366GH PRG364GDH PRL364GDH REQuiRED ciRcuiT BREAkER 120V AC, 60 Hz 15 Amp 15 Amp 15 Amp 15 Amp 20 Amp 20 Amp important...technician. Dual-fuel models are LP convertible by the appliance. water column. (27.4 mb to 34.9 mb) Manifold Pressure: 10" water column (24.9 mb) DuAL-FuEL: Thermador Pro Harmony Dual-Fuel Ranges are dual rated, designed to be connected to a 120V AC, 60 Hz, single-phase power supply...
Design Guide - Pro Harmony Ranges
Page 8
...and accessories. iMPORTANT We strongly recommend that must be considered when planning the installation. Note: Most hoods contain combustible components that a Thermador Professional Wall or Island Hood or Custom Insert be attached before sliding the range into the final installed position. Field conversion...RANGES 30-iNch DuAL-FuEL Model: PRD304Ghu 30-INCH CuTOuT AND RANGE DIMENSIONS *min. 30"- 40" 30" 24" 513/16" **min.10" 187/16" 215/16" Gas and Electric connections * 30" minimum clearance above cooking surface to combustible surface is used. measurement in inches...
...and accessories. iMPORTANT We strongly recommend that must be considered when planning the installation. Note: Most hoods contain combustible components that a Thermador Professional Wall or Island Hood or Custom Insert be attached before sliding the range into the final installed position. Field conversion...RANGES 30-iNch DuAL-FuEL Model: PRD304Ghu 30-INCH CuTOuT AND RANGE DIMENSIONS *min. 30"- 40" 30" 24" 513/16" **min.10" 187/16" 215/16" Gas and Electric connections * 30" minimum clearance above cooking surface to combustible surface is used. measurement in inches...
Design Guide - Pro Harmony Ranges
Page 10
...be considered when planning the installation. Do not install a microwave-hood combination above the cooktop, as these ranges. BAckGuARD 36-inch Thermador Pro Harmony Ranges require an accessory backguard. An island trim is included for covering the backguard mounting flanges for these types... a minimum of 12" of horizontal clearance behind the island trim. Field conversion must be installed whenever the range is 40". ** 10" minimum clearance from natural gas to combustible side walls. The PH Professional Series Wall Hoods are shipped by the appliance. Either backguard ...
...be considered when planning the installation. Do not install a microwave-hood combination above the cooktop, as these ranges. BAckGuARD 36-inch Thermador Pro Harmony Ranges require an accessory backguard. An island trim is included for covering the backguard mounting flanges for these types... a minimum of 12" of horizontal clearance behind the island trim. Field conversion must be installed whenever the range is 40". ** 10" minimum clearance from natural gas to combustible side walls. The PH Professional Series Wall Hoods are shipped by the appliance. Either backguard ...
Design Guide - Pro Harmony Ranges
Page 12
... Series Custom Inserts are not suitable for a complete selection of Professional ventilation options, blowers, and accessories. BAckGuARD 36-inch Thermador Pro Harmony Ranges require an accessory backguard. Field conversion must be done by qualified service personnel only. iMPORTANT We... range must be installed with shelf. Downdraft ventilation should not be installed whenever the range is 40". ** 10" minimum clearance from natural gas to all Thermador Pro Harmony Ranges. cAuTiON: To avoid possible burn or fire hazard, a backguard designed specifically...
... Series Custom Inserts are not suitable for a complete selection of Professional ventilation options, blowers, and accessories. BAckGuARD 36-inch Thermador Pro Harmony Ranges require an accessory backguard. Field conversion must be done by qualified service personnel only. iMPORTANT We... range must be installed with shelf. Downdraft ventilation should not be installed whenever the range is 40". ** 10" minimum clearance from natural gas to all Thermador Pro Harmony Ranges. cAuTiON: To avoid possible burn or fire hazard, a backguard designed specifically...
Design Guide - Pro Harmony Ranges
Page 14
...designed specifically for this range must be installed whenever the range is 40". ** 10" minimum clearance from natural gas to non-combustible surface. NATuRAL GAS OR LP Thermador Dual-Fuel Pro Harmony Ranges are not suitable for further information. Field conversion must be done ... cooking surface to combustible side walls. Either backguard must be installed in inches 357/8"363/4" 1.800.735.4328 | THERMADOR.COM 53 Verify that a Thermador Professional Wall or Island Hood or Custom Insert be attached before sliding the range into the final installed position....
...designed specifically for this range must be installed whenever the range is 40". ** 10" minimum clearance from natural gas to non-combustible surface. NATuRAL GAS OR LP Thermador Dual-Fuel Pro Harmony Ranges are not suitable for further information. Field conversion must be done ... cooking surface to combustible side walls. Either backguard must be installed in inches 357/8"363/4" 1.800.735.4328 | THERMADOR.COM 53 Verify that a Thermador Professional Wall or Island Hood or Custom Insert be attached before sliding the range into the final installed position....
Design Guide - Pro Harmony Ranges
Page 16
... LP Thermador All-Gas Pro Harmony Ranges are recommended ventilation solutions for this range must be attached before sliding the range into the final installed position. PRO hARMONY® RANGES 30-iNch GAS Models: PRG304Gh / PRL304Gh 30-INCH CuTOuT AND RANGE DIMENSIONS *min. 30"- 40" 30" 24" 513/16" **min.10" 187...
... LP Thermador All-Gas Pro Harmony Ranges are recommended ventilation solutions for this range must be attached before sliding the range into the final installed position. PRO hARMONY® RANGES 30-iNch GAS Models: PRG304Gh / PRL304Gh 30-INCH CuTOuT AND RANGE DIMENSIONS *min. 30"- 40" 30" 24" 513/16" **min.10" 187...
Design Guide - Pro Harmony Ranges
Page 18
... designed specifically for island installations, where there is 40". ** 10" minimum clearance from cooking surface to all Thermador Pro Harmony Ranges. Due to the Ventilation section or www.Thermador.com for these types of gas used . PRO hARMONY® RANGES 36...81/8" 1913/16" 33/16" **min. 10" Gas and Electric connections * 30" minimum clearance above the cooktop, as these ranges. iMPORTANT We strongly recommend that creates a seamless look within standard cabinetry. PRO hARMONY RANGES iNSTALLATiON OPTiONS Thermador Pro Harmony® Ranges feature a bold,...
... designed specifically for island installations, where there is 40". ** 10" minimum clearance from cooking surface to all Thermador Pro Harmony Ranges. Due to the Ventilation section or www.Thermador.com for these types of gas used . PRO hARMONY® RANGES 36...81/8" 1913/16" 33/16" **min. 10" Gas and Electric connections * 30" minimum clearance above the cooktop, as these ranges. iMPORTANT We strongly recommend that creates a seamless look within standard cabinetry. PRO hARMONY RANGES iNSTALLATiON OPTiONS Thermador Pro Harmony® Ranges feature a bold,...
Design Guide - Pro Harmony Ranges
Page 20
... clearance above cooking surface to the high surface temperature output of horizontal clearance behind the island trim. PRO HaRmOny RanGES InSTaLLaTIOn OPTIOnS Thermador Pro Harmony® Ranges feature a bold, professional design and a compact, 24-inch depth profile that must be ...burn or fire hazard, a backguard designed specifically for island installations, where there is 40". ** 10" minimum clearance from cooking surface to all Thermador Pro Harmony Ranges. Downdraft ventilation should not be installed whenever the range is used . Do not install a microwave...
... clearance above cooking surface to the high surface temperature output of horizontal clearance behind the island trim. PRO HaRmOny RanGES InSTaLLaTIOn OPTIOnS Thermador Pro Harmony® Ranges feature a bold, professional design and a compact, 24-inch depth profile that must be ...burn or fire hazard, a backguard designed specifically for island installations, where there is 40". ** 10" minimum clearance from cooking surface to all Thermador Pro Harmony Ranges. Downdraft ventilation should not be installed whenever the range is used . Do not install a microwave...
Installation Instructions
Page 2
... 7: Backguard Installation 13 Step 8: Door Removal and Reinstallation 14 Step 9: Placing and Leveling the Range 15 Step 10: Burner Test and Adjustment 17 Installer Checklist 18 To Clean and Protect Exterior Surfaces 18 This Thermador Appliance is made by BSH Home Appliances Corporation 5551 McFadden Ave. Huntington Beach, CA 92649 Questions? 1-800...
... 7: Backguard Installation 13 Step 8: Door Removal and Reinstallation 14 Step 9: Placing and Leveling the Range 15 Step 10: Burner Test and Adjustment 17 Installer Checklist 18 To Clean and Protect Exterior Surfaces 18 This Thermador Appliance is made by BSH Home Appliances Corporation 5551 McFadden Ave. Huntington Beach, CA 92649 Questions? 1-800...
Installation Instructions
Page 4
...building codes. Select Hood and Blower Models: • For wall installations, the hood width must be installed in accordance with all applicable codes. A Thermador backguard must , at the rear of the range. Based on page 4. The following standards: • UL 858, Standard for the Safety of ...mb) min., 14 inch (34.9 mb) maximum Electric Power Supply: 30" Model: 4 Burners - 120 VAC, 60 Hz., 1Ph., 10 Amp circuit. 36" Models: 6 Burners - 120 VAC, 60 Hz., 1Ph., 10 Amp circuit 4 Burners with Griddle - 120 VAC, 60 Hz., 1Ph., 20 Amp circuit. 48" Models: 6 Burners with a Flush Island...
...building codes. Select Hood and Blower Models: • For wall installations, the hood width must be installed in accordance with all applicable codes. A Thermador backguard must , at the rear of the range. Based on page 4. The following standards: • UL 858, Standard for the Safety of ...mb) min., 14 inch (34.9 mb) maximum Electric Power Supply: 30" Model: 4 Burners - 120 VAC, 60 Hz., 1Ph., 10 Amp circuit. 36" Models: 6 Burners - 120 VAC, 60 Hz., 1Ph., 10 Amp circuit 4 Burners with Griddle - 120 VAC, 60 Hz., 1Ph., 20 Amp circuit. 48" Models: 6 Burners with a Flush Island...
Installation Instructions
Page 9
Gas and Electric Supply Figure 3a: Gas & Electrical Supply Locations for 30" and 36" Gas Ranges 2-1/2" maximum protrusion from wall for gas or electrical supply Gas Supply Zone 4-3/8" Electrical Supply Zone 2-1/2" 4-3/8" 10-3/4" 48" 18-11/16" 5-15/16" Figure 3b: Gas & Electrical Supply Locations for 48" Gas Ranges English 7
Gas and Electric Supply Figure 3a: Gas & Electrical Supply Locations for 30" and 36" Gas Ranges 2-1/2" maximum protrusion from wall for gas or electrical supply Gas Supply Zone 4-3/8" Electrical Supply Zone 2-1/2" 4-3/8" 10-3/4" 48" 18-11/16" 5-15/16" Figure 3b: Gas & Electrical Supply Locations for 48" Gas Ranges English 7
Installation Instructions
Page 12
...ruler • 1/8" drill bit (wood or metal wall or floor) • 3/16" carbide-tipped masonry drill bit (concrete or concrete block wall or floor) English 10 Figure 7: Anti-tip Bracket Note: 48" Ranges do not require the Anti-Tip Bracket. Qty 415078 4 647936 1 Description Screw, Phillips... • See Installation Instructions. • 3/16" anchors, drywall or concrete, 4 each (not required if mounting bracket is being attached to wall or floor coverings. ATTENTION - Thermador Service Part No. Personal injury might result from spilled hot liquids or from the range itself.
...ruler • 1/8" drill bit (wood or metal wall or floor) • 3/16" carbide-tipped masonry drill bit (concrete or concrete block wall or floor) English 10 Figure 7: Anti-tip Bracket Note: 48" Ranges do not require the Anti-Tip Bracket. Qty 415078 4 647936 1 Description Screw, Phillips... • See Installation Instructions. • 3/16" anchors, drywall or concrete, 4 each (not required if mounting bracket is being attached to wall or floor coverings. ATTENTION - Thermador Service Part No. Personal injury might result from spilled hot liquids or from the range itself.
Installation Instructions
Page 13
... 8 (Bracket may be used at the installation site. water column. (14.9 to 14" max. Later, when the unit is moved to 34.9 mb) Manifold Pressure: 10" water column (24.9 mb) WARNING Gas line must be installed as follows: 1. Figure 8: Placement of Anti-Tip Bracket (Top View) For installation of the appliance...
... 8 (Bracket may be used at the installation site. water column. (14.9 to 14" max. Later, when the unit is moved to 34.9 mb) Manifold Pressure: 10" water column (24.9 mb) WARNING Gas line must be installed as follows: 1. Figure 8: Placement of Anti-Tip Bracket (Top View) For installation of the appliance...
Installation Instructions
Page 14
..." Ranges Step 6: Electrical Requirements, Connection & Grounding Before installing, turn power OFF at the service panel. English 12 A Figure 9: Location of Gas Supply Inlet Connection A Figure 10: Location of the unit. Hook Up • A manual gas shut-off valve must be at least 6.0" (14.9 mb) W.C.
..." Ranges Step 6: Electrical Requirements, Connection & Grounding Before installing, turn power OFF at the service panel. English 12 A Figure 9: Location of Gas Supply Inlet Connection A Figure 10: Location of the unit. Hook Up • A manual gas shut-off valve must be at least 6.0" (14.9 mb) W.C.
Installation Instructions
Page 15
... supply connection shall be in accordance with griddle Chart B: Electrical Supply Circuit Requirements VOLTAGE CIRCUIT RATING FREQUENCY 120 VAC 120 VAC 120 VAC 120 VAC 10 Amps 10 Amps 20 Amps 20 Amps 60 Hz. 60 Hz. 60 Hz. 60 Hz. PHASE Single Single Single Single • For these gas range models...
... supply connection shall be in accordance with griddle Chart B: Electrical Supply Circuit Requirements VOLTAGE CIRCUIT RATING FREQUENCY 120 VAC 120 VAC 120 VAC 120 VAC 10 Amps 10 Amps 20 Amps 20 Amps 60 Hz. 60 Hz. 60 Hz. 60 Hz. PHASE Single Single Single Single • For these gas range models...
Installation Instructions
Page 19
... that causes the flame to maintain the temperature. Test Oven Burners Remove the oven bottom cover. Step 10: Burner Test and Adjustment Install any burners do not improve, call Thermador. Push in and turn counterclockwise to the bottom of the rangetop burners continue to the XLO range. ...If any loose components, such as "carry over ", call Thermador. Figure 13: Flame Characteristics When Flame is set to burn mostly or completely yellow, verify that may have been carefully checked for each...
... that causes the flame to maintain the temperature. Test Oven Burners Remove the oven bottom cover. Step 10: Burner Test and Adjustment Install any burners do not improve, call Thermador. Push in and turn counterclockwise to the bottom of the rangetop burners continue to the XLO range. ...If any loose components, such as "carry over ", call Thermador. Figure 13: Flame Characteristics When Flame is set to burn mostly or completely yellow, verify that may have been carefully checked for each...
User Manual
Page 2
... Time . . 7 Description 9 Model and Parts Identification - 48" Range . . 9 Model and Parts Identification - 36" Range . 10 Model and Parts Identification - 30" Range . 10 Using the Cooktop 11 Cookware Recommendations 15 Specialty Cookware 16 Cooking Recommendations 16 Surface Burner Cooking Recommendations . 17 Using the Electric Griddle...Do-It-Yourself Maintenance 33 Before Calling For Service . . . 34 STATEMENT OF LIMITED PRODUCT WARRANTY 35 This Thermador Appliance is made by BSH Home Appliances Corporation 5551 McFadden Ave. Huntington Beach, CA 92649 Questions? 1-800-735-4328 www...
... Time . . 7 Description 9 Model and Parts Identification - 48" Range . . 9 Model and Parts Identification - 36" Range . 10 Model and Parts Identification - 30" Range . 10 Using the Cooktop 11 Cookware Recommendations 15 Specialty Cookware 16 Cooking Recommendations 16 Surface Burner Cooking Recommendations . 17 Using the Electric Griddle...Do-It-Yourself Maintenance 33 Before Calling For Service . . . 34 STATEMENT OF LIMITED PRODUCT WARRANTY 35 This Thermador Appliance is made by BSH Home Appliances Corporation 5551 McFadden Ave. Huntington Beach, CA 92649 Questions? 1-800-735-4328 www...
User Manual
Page 4
... responsibility and obligation of heat and moisture. See Installation Instructions for more information. 30" Gas Models: 120 volts, 60 Hz., 10 Amp electrical circuit required. 36" Gas Models: 120 volts, 60 Hz., 10 Amp electrical circuit required. 36" gas range with electric griddle - 20 Amp circuit required. 48" Gas Models with propane...
... responsibility and obligation of heat and moisture. See Installation Instructions for more information. 30" Gas Models: 120 volts, 60 Hz., 10 Amp electrical circuit required. 36" Gas Models: 120 volts, 60 Hz., 10 Amp electrical circuit required. 36" gas range with electric griddle - 20 Amp circuit required. 48" Gas Models with propane...
User Manual
Page 11
...9. Kick Panel 13. Gliding Oven Racks (3 included) 19. Control Knobs, ExtraLow® Burners (2) 5. Broil Burner 16. Oven Door 10. Oven Thermostat Sensor 17. Convection Fan Cover 21. Control Knobs, Standard Burners (4) 6. Control Knob, Griddle (1) 7. Broil Glow Igniter ...(hidden) 20. Electric Griddle 4. Secondary Oven (2 gliding racks included) 12. Range Feet (4) 1 2 2 2 3 4 5 8 7786 5 9 10 11 12 13 14. Rack Guides 18. Oven Temperature Selectors, Main and Secondary Ovens 8. Viewing Window 11. Description Model and Parts Identification - 48" Range ...
...9. Kick Panel 13. Gliding Oven Racks (3 included) 19. Control Knobs, ExtraLow® Burners (2) 5. Broil Burner 16. Oven Door 10. Oven Thermostat Sensor 17. Convection Fan Cover 21. Control Knobs, Standard Burners (4) 6. Control Knob, Griddle (1) 7. Broil Glow Igniter ...(hidden) 20. Electric Griddle 4. Secondary Oven (2 gliding racks included) 12. Range Feet (4) 1 2 2 2 3 4 5 8 7786 5 9 10 11 12 13 14. Rack Guides 18. Oven Temperature Selectors, Main and Secondary Ovens 8. Viewing Window 11. Description Model and Parts Identification - 48" Range ...