Manual
Page 14
... the calendar after battery change After the battery is moving at two-second intervals, the date will stop operating in a couple of days * The time accuracy is not affected even if the second hand is moving at two-second intervals. * While the second hand is replaced with a new one , be sure...
... the calendar after battery change After the battery is moving at two-second intervals, the date will stop operating in a couple of days * The time accuracy is not affected even if the second hand is moving at two-second intervals. * While the second hand is replaced with a new one , be sure...
Technical Guide
Page 15
...that case, overhaul and clean the movement parts, and then measure the current consumption for the whole movement again. ● Checking the accuracy In order to check the accuracy, set the gate time of the quartz tester to the pattern of the negative (-) terminal of the tester to 10 seconds, and... measure the accuracy with the coil block installed on the main plate. 2. If the current consumption for approximately one minute until the current consumption becomes stable. ...
...that case, overhaul and clean the movement parts, and then measure the current consumption for the whole movement again. ● Checking the accuracy In order to check the accuracy, set the gate time of the quartz tester to the pattern of the negative (-) terminal of the tester to 10 seconds, and... measure the accuracy with the coil block installed on the main plate. 2. If the current consumption for approximately one minute until the current consumption becomes stable. ...