Savvio 10K.1 SAS Product Manual
Page 4
... 43 8.4 Grounding 43 9.0 Interface requirements 45 9.1 SAS features 45 9.1.1 task management functions 45 9.1.2 task management responses 45 9.2 Dual port support 46 9.3 SCSI commands supported 47 9.3.1 Inquiry data 51 9.3.2 Mode Sense data 51 9.4 Miscellaneous operating features and conditions 55 9.4.1 SAS physical interface 56 9.4.2 Physical characteristics ... SAS transmitters and receivers 60 9.4.7 Power 61 9.5 Signal characteristics 61 9.5.1 Ready LED Out 61 9.5.2 Differential signals 61 10.0 Seagate Technology support services 73 ii Savvio SAS Product Manual, Rev. D
... 43 8.4 Grounding 43 9.0 Interface requirements 45 9.1 SAS features 45 9.1.1 task management functions 45 9.1.2 task management responses 45 9.2 Dual port support 46 9.3 SCSI commands supported 47 9.3.1 Inquiry data 51 9.3.2 Mode Sense data 51 9.4 Miscellaneous operating features and conditions 55 9.4.1 SAS physical interface 56 9.4.2 Physical characteristics ... SAS transmitters and receivers 60 9.4.7 Power 61 9.5 Signal characteristics 61 9.5.1 Ready LED Out 61 9.5.2 Differential signals 61 10.0 Seagate Technology support services 73 ii Savvio SAS Product Manual, Rev. D
Savvio 10K.1 SAS Product Manual
Page 7
Savvio family disc drive Savvio SAS Product Manual, Rev. Figure 1. 1.0 Scope This manual describes Seagate Technology® LLC, Savvio® SAS (Serial Attached SCSI) disc drives. D 1 The SAS Interface Manual (part number 100293071) describes the general SAS characteristics of this manual. Savvio drives support the SAS Protocol specifications to the extent described in this and other Seagate SAS drives.
Savvio family disc drive Savvio SAS Product Manual, Rev. Figure 1. 1.0 Scope This manual describes Seagate Technology® LLC, Savvio® SAS (Serial Attached SCSI) disc drives. D 1 The SAS Interface Manual (part number 100293071) describes the general SAS characteristics of this manual. Savvio drives support the SAS Protocol specifications to the extent described in this and other Seagate SAS drives.
Savvio 10K.1 SAS Product Manual
Page 13
... performance with either SAS or SATA hard disc drives. The drive does not contain user-replaceable parts. An automatic shipping lock prevents potential damage to support the Serial Attached SCSI Protocol as described in the ANSI specifications, this document, and the SAS Interface Manual (part number 100293071) which describes the general...
... performance with either SAS or SATA hard disc drives. The drive does not contain user-replaceable parts. An automatic shipping lock prevents potential damage to support the Serial Attached SCSI Protocol as described in the ANSI specifications, this document, and the SAS Interface Manual (part number 100293071) which describes the general...
Savvio 10K.1 SAS Product Manual
Page 14
...multi-segmentable cache buffer • 300 Mbytes/sec maximum instantaneous data transfers. • 10k RPM spindle. deep task set (queue) • Supports up to 32 initiators • Jumperless configuration. • User-selectable logical block size (512 to the drive • Zone bit recording ...; Power Save 3.2 Media description The media used on command (Post Format) • ECC maximum burst correction length of queue • Supports start and stop commands (spindle stops spinning) • Adaptive seek velocity; Average latency = 3.0 msec • Background processing of 320 ...
...multi-segmentable cache buffer • 300 Mbytes/sec maximum instantaneous data transfers. • 10k RPM spindle. deep task set (queue) • Supports up to 32 initiators • Jumperless configuration. • User-selectable logical block size (512 to the drive • Zone bit recording ...; Power Save 3.2 Media description The media used on command (Post Format) • ECC maximum burst correction length of queue • Supports start and stop commands (spindle stops spinning) • Adaptive seek velocity; Average latency = 3.0 msec • Background processing of 320 ...
Savvio 10K.1 SAS Product Manual
Page 20
... transfers the remaining requested logical blocks from the cache to be written are already stored in bit 4 of byte 2 of user-selectable configurations. The drive supports operation of a drive buffer storage area where the data to the host in any segment of segments to section 4.5.2 for operation from this point. The...
... transfers the remaining requested logical blocks from the cache to be written are already stored in bit 4 of byte 2 of user-selectable configurations. The drive supports operation of a drive buffer storage area where the data to the host in any segment of segments to section 4.5.2 for operation from this point. The...
Savvio 10K.1 SAS Product Manual
Page 45
... limited using the Read Retry Count or Write Retry Count bytes in video applications. The total amount of the SCSI commands supported by the initiator using several SCSI commands described in the Error Recovery mode page. The drive firmware error recovery algorithms consists... of defect management routines by the drive in this product manual. The error recovery scheme supported by the read and write retry count with this section. Reallocations are described in communications between the initiator and the drive). ...
... limited using the Read Retry Count or Write Retry Count bytes in video applications. The total amount of the SCSI commands supported by the initiator using several SCSI commands described in the Error Recovery mode page. The drive firmware error recovery algorithms consists... of defect management routines by the drive in this product manual. The error recovery scheme supported by the read and write retry count with this section. Reallocations are described in communications between the initiator and the drive). ...
Savvio 10K.1 SAS Product Manual
Page 51
...05 Function succeeded 08 Invalid logical unit 09 Savvio SAS Product Manual, Rev. Table 15: SAS task management functions supported Task name Abort Task Clear ACA Supported Yes Yes Clear task set Yes Abort task set Yes Logical Unit Reset Yes Query Task Yes 9.1.2 task management... responses Table 16 lists the SAS response codes returned for task management functions supported. D 45 Additional information is provided in the SAS Interface Manual (part number 100293071). 9.1 SAS features This section lists the SAS-...
...05 Function succeeded 08 Invalid logical unit 09 Savvio SAS Product Manual, Rev. Table 15: SAS task management functions supported Task name Abort Task Clear ACA Supported Yes Yes Clear task set Yes Abort task set Yes Logical Unit Reset Yes Query Task Yes 9.1.2 task management... responses Table 16 lists the SAS response codes returned for task management functions supported. D 45 Additional information is provided in the SAS Interface Manual (part number 100293071). 9.1 SAS features This section lists the SAS-...
Savvio 10K.1 SAS Product Manual
Page 52
...management transfers on both ports. 46 Savvio SAS Product Manual, Rev. These ports may be connected in speed negotiation, it indicates the only supported speed is the speed selected by both ports. If the first port to complete speed negotiation looses sync before the second port completes speed negotiation... to the power on both ports at the same link rate. The two ports run at the same time. • Full duplex-The drive supports sending XFER_RDY, DATA and RESPONSE transfers while receiving frames on condition of allowing either link rate (1.5 or 3.0 Gbits/sec). Each drive port has ...
...management transfers on both ports. 46 Savvio SAS Product Manual, Rev. These ports may be connected in speed negotiation, it indicates the only supported speed is the speed selected by both ports. If the first port to complete speed negotiation looses sync before the second port completes speed negotiation... to the power on both ports at the same link rate. The two ports run at the same time. • Full duplex-The drive supports sending XFER_RDY, DATA and RESPONSE transfers while receiving frames on condition of allowing either link rate (1.5 or 3.0 Gbits/sec). Each drive port has ...
Savvio 10K.1 SAS Product Manual
Page 53
... Savvio SAS family drive Command name Change Definition Compare Copy Copy and Verify Format Unit [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented ...Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD bit ETC...
... Savvio SAS family drive Command name Change Definition Compare Copy Copy and Verify Format Unit [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented ...Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD bit ETC...
Savvio 10K.1 SAS Product Manual
Page 54
... drive (continued) Command name Last n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) Self-test Results page (10h) Start-stop Cycle Counter page (0Eh) ... (same pages as Mode Sense 1Ah) Persistent Reserve In Persistent Reserve Out Prefetch Read (6) Read (10) DPO bit supported FUA bit supported Read (12) Read (16) Read (32) Read Buffer (modes 0, 2, 3, Ah and Bh supported) Command code 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h 7Fh/0009h 3Ch...
... drive (continued) Command name Last n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) Self-test Results page (10h) Start-stop Cycle Counter page (0Eh) ... (same pages as Mode Sense 1Ah) Persistent Reserve In Persistent Reserve Out Prefetch Read (6) Read (10) DPO bit supported FUA bit supported Read (12) Read (16) Read (32) Read Buffer (modes 0, 2, 3, Ah and Bh supported) Command code 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h 7Fh/0009h 3Ch...
Savvio 10K.1 SAS Product Manual
Page 55
... Read Capacity (16) Read Defect Data (10) Read Defect Data (12) Read Long Read Long (16) Reassign Blocks Receive Diagnostic Results Supported Diagnostics pages (00h) Translate page (40h) Release Release (10) Report LUNs Request Sense Actual Retry Count bytes Extended Sense Field Pointer bytes ... (10) 3rd Party Reserve Extent Reservation Rezero Unit Search Data Equal Search Data High Search Data Low Seek (6) Seek (10) Send Diagnostics Supported Diagnostics pages (00h) Translate page (40h) Set Limits Start Unit/Stop Unit (spindle ceases rotating) Synchronize Cache Synchronize Cache (16) Test ...
... Read Capacity (16) Read Defect Data (10) Read Defect Data (12) Read Long Read Long (16) Reassign Blocks Receive Diagnostic Results Supported Diagnostics pages (00h) Translate page (40h) Release Release (10) Report LUNs Request Sense Actual Retry Count bytes Extended Sense Field Pointer bytes ... (10) 3rd Party Reserve Extent Reservation Rezero Unit Search Data Equal Search Data High Search Data Low Seek (6) Seek (10) Send Diagnostics Supported Diagnostics pages (00h) Translate page (40h) Set Limits Start Unit/Stop Unit (spindle ceases rotating) Synchronize Cache Synchronize Cache (16) Test ...
Savvio 10K.1 SAS Product Manual
Page 56
... Verify (10) DPO bit Write and Verify (12) Write and Verify (16) Write and Verify (32) Write Buffer (modes 0, 2, supported) Firmware Download option (modes 5, 7, Ah and Bh supported) [3] Write Long (10) Write Long (16) Write Same (10) PBdata LBdata Write Same (16) Write Same (32) XDRead XDWrite XPWrite... AFh 7Fh/000Ah 0Ah 2Ah AAh 8Ah 7Fh/000Bh 2Eh AEh 8Eh 7Fh/000Ch 3Bh 3Fh 9Fh/11h 41h 93h 7Fh/000Dh 52h 50h 51h Supported N N N Y Y Y Y N N N Y Y N N N Y Y Y N Y N N N N N N N [1] Savvio drives can result in the range 512 to any multiple of four bytes per logical block in firmware corruption. ...
... Verify (10) DPO bit Write and Verify (12) Write and Verify (16) Write and Verify (32) Write Buffer (modes 0, 2, supported) Firmware Download option (modes 5, 7, Ah and Bh supported) [3] Write Long (10) Write Long (16) Write Same (10) PBdata LBdata Write Same (16) Write Same (32) XDRead XDWrite XPWrite... AFh 7Fh/000Ah 0Ah 2Ah AAh 8Ah 7Fh/000Bh 2Eh AEh 8Eh 7Fh/000Ch 3Bh 3Fh 9Fh/11h 41h 93h 7Fh/000Dh 52h 50h 51h Supported N N N Y Y Y Y N N N Y Y N N N Y Y Y N Y N N N N N N N [1] Savvio drives can result in the range 512 to any multiple of four bytes per logical block in firmware corruption. ...
Savvio 10K.1 SAS Product Manual
Page 61
...Reporting actual retry count in Extended Sense bytes 15, 16, and 17 Adaptive caching SMP = 1 in the support column indicates the feature or condition is supported. Table 21: Miscellaneous features Supported N N N Y N Y Y Y Y N Y Feature or condition Automatic contingent allegiance Asynchronous event ...locked) spindle operation Segmented caching Zero latency read Queue tagging (up to save RPL and rotational offset bytes Table 22: Miscellaneous status Supported Y Y Y Y Y Y Y Y N N Status Good Check condition Condition met/good Busy Intermediate/good Intermediate/condition met/good...
...Reporting actual retry count in Extended Sense bytes 15, 16, and 17 Adaptive caching SMP = 1 in the support column indicates the feature or condition is supported. Table 21: Miscellaneous features Supported N N N Y N Y Y Y Y N Y Feature or condition Automatic contingent allegiance Asynchronous event ...locked) spindle operation Segmented caching Zero latency read Queue tagging (up to save RPL and rotational offset bytes Table 22: Miscellaneous status Supported Y Y Y Y Y Y Y Y N N Status Good Check condition Condition met/good Busy Intermediate/good Intermediate/condition met/good...
Savvio 10K.1 SAS Product Manual
Page 66
... 12 Volts charge P14 12 Volts * P15 12 Volts * 9.4.6 SAS transmitters and receivers A typical SAS differential copper transmitter and receiver pair is AC coupling to support hot plugging NC - input pair S3* -Port A_in S4 Port A Ground S5* -Port A_out Diff output pair S6* +Port A_out S7 Port A Ground S8 Port...
... 12 Volts charge P14 12 Volts * P15 12 Volts * 9.4.6 SAS transmitters and receivers A typical SAS differential copper transmitter and receiver pair is AC coupling to support hot plugging NC - input pair S3* -Port A_in S4 Port A Ground S5* -Port A_out Diff output pair S6* +Port A_out S7 Port A Ground S8 Port...
Savvio 10K.1 SAS Product Manual
Page 71
... the common mode voltage between the burst times and the idle times of an OOB signal. All specifications are measured from 20 % to the lowest supported transfer rate. Savvio SAS Product Manual, Rev. b The skew measurement shall be used for both the Tx+ and Tx- idle (e.g., during idle time of an...
... the common mode voltage between the burst times and the idle times of an OOB signal. All specifications are measured from 20 % to the lowest supported transfer rate. Savvio SAS Product Manual, Rev. b The skew measurement shall be used for both the Tx+ and Tx- idle (e.g., during idle time of an...
Savvio 10K.1 SAS Product Manual
Page 79
... suited for your "ST" model number available. spp.seagate.com spp.seagate.com supports Seagate resellers with a technical support specialist during normal business hours for the deaf (TDD). D 73 10.0 Seagate Technology support services Internet For information regarding Seagate products and services, visit www.seagate.com. Seagate Service Centers Presales Support Our Presales Support staff can send questions or comments 24 hours...
... suited for your "ST" model number available. spp.seagate.com spp.seagate.com supports Seagate resellers with a technical support specialist during normal business hours for the deaf (TDD). D 73 10.0 Seagate Technology support services Internet For information regarding Seagate products and services, visit www.seagate.com. Seagate Service Centers Presales Support Our Presales Support staff can send questions or comments 24 hours...
Savvio 10K.1 SAS Product Manual
Page 80
...the return of defective products. Our data recovery services labs are available on www.seagate.com. Global Customer Support Presales, Technical, and Warranty Support Call Center Toll-free USA, Canada, and Mexico 1-800-SEAGATE Data Recovery Services Call Center USA, Canada, and Mexico Toll-free 1-800-475... East and Africa, go to the "Contact Us" page on www.seagate.com. 74 Savvio SAS Product Manual, Rev. Asia/Pacific Support Services For an extensive list of telephone numbers to technical support, presales and warranty service in Asia/Pacific, go to the "Contact ...
...the return of defective products. Our data recovery services labs are available on www.seagate.com. Global Customer Support Presales, Technical, and Warranty Support Call Center Toll-free USA, Canada, and Mexico 1-800-SEAGATE Data Recovery Services Call Center USA, Canada, and Mexico Toll-free 1-800-475... East and Africa, go to the "Contact Us" page on www.seagate.com. 74 Savvio SAS Product Manual, Rev. Asia/Pacific Support Services For an extensive list of telephone numbers to technical support, presales and warranty service in Asia/Pacific, go to the "Contact ...
Savvio 10K.1 SAS Product Manual
Page 81
...11 case temperature 32 check condition status 55 class B limit 3 clear ACA function 45 clear task set function 45 commands supported 47 condensation 32 condition met/good status 55 connector illustrated 59 requirements 59 continuous vibration 35 cooling 42 CRC error 18 Current...speed 11 drive 35 drive characteristics 11 drive failure 18 drive malfunction 18 drive mounting 37, 43 drive select 59 dual port support 46 E electrical description of connector 59 signal characteristics 61 specifications 25 electromagnetic compatibility 3 electromagnetic susceptibility 36 EMI requirements 3 environment ...
...11 case temperature 32 check condition status 55 class B limit 3 clear ACA function 45 clear task set function 45 commands supported 47 condensation 32 condition met/good status 55 connector illustrated 59 requirements 59 continuous vibration 35 cooling 42 CRC error 18 Current...speed 11 drive 35 drive characteristics 11 drive failure 18 drive malfunction 18 drive mounting 37, 43 drive select 59 dual port support 46 E electrical description of connector 59 signal characteristics 61 specifications 25 electromagnetic compatibility 3 electromagnetic susceptibility 36 EMI requirements 3 environment ...
Savvio 10K.1 SAS Product Manual
Page 82
... head and disc assembly (HDA) 7 head and disc assembly. D See MTBF media description 8 minimum sector interleave 12 miscellaneous feature support Adaptive caching 55 Asynchronous event notification 55 Automatic contingent allegiance 55 Deferred error handling 55 Parameter rounding 55 Queue tagging 55 Reporting actual retry...equipment 43 hot plugging the drive 19 humidity 32 humidity limits 32 I inquiry data 51 installation 41 guide 5 interface commands supported 47 error rate 17 errors 18 illustrated 56 physical 56 requirements 45 interleave minimum 12 intermediate/condition met/good status 55 ...
... head and disc assembly (HDA) 7 head and disc assembly. D See MTBF media description 8 minimum sector interleave 12 miscellaneous feature support Adaptive caching 55 Asynchronous event notification 55 Automatic contingent allegiance 55 Deferred error handling 55 Parameter rounding 55 Queue tagging 55 Reporting actual retry...equipment 43 hot plugging the drive 19 humidity 32 humidity limits 32 I inquiry data 51 installation 41 guide 5 interface commands supported 47 error rate 17 errors 18 illustrated 56 physical 56 requirements 45 interleave minimum 12 intermediate/condition met/good status 55 ...
Savvio 10K.1 SAS Product Manual
Page 83
... return information 24 rotation speed 11 S safety 3 SAS interface 59 physical interface 56 task management functions 45 SAS documents 5 SAS Interface Manual 3, 5 SCSI interface commands supported 47 seek error defined 18 rate 17 seek performance characteristics 11 seek time average typical 11 full stroke typical 11 single track typical 11 segmented...
... return information 24 rotation speed 11 S safety 3 SAS interface 59 physical interface 56 task management functions 45 SAS documents 5 SAS Interface Manual 3, 5 SCSI interface commands supported 47 seek error defined 18 rate 17 seek performance characteristics 11 seek time average typical 11 full stroke typical 11 single track typical 11 segmented...