Savvio 10K.1 SAS Product Manual
Page 4
... 43 8.4 Grounding 43 9.0 Interface requirements 45 9.1 SAS features 45 9.1.1 task management functions 45 9.1.2 task management responses 45 9.2 Dual port support 46 9.3 SCSI commands supported 47 9.3.1 Inquiry data 51 9.3.2 Mode Sense data 51 9.4 Miscellaneous operating features and conditions 55 9.4.1 SAS physical interface 56 9.4.2 Physical characteristics ... SAS transmitters and receivers 60 9.4.7 Power 61 9.5 Signal characteristics 61 9.5.1 Ready LED Out 61 9.5.2 Differential signals 61 10.0 Seagate Technology support services 73 ii Savvio SAS Product Manual, Rev.
... 43 8.4 Grounding 43 9.0 Interface requirements 45 9.1 SAS features 45 9.1.1 task management functions 45 9.1.2 task management responses 45 9.2 Dual port support 46 9.3 SCSI commands supported 47 9.3.1 Inquiry data 51 9.3.2 Mode Sense data 51 9.4 Miscellaneous operating features and conditions 55 9.4.1 SAS physical interface 56 9.4.2 Physical characteristics ... SAS transmitters and receivers 60 9.4.7 Power 61 9.5 Signal characteristics 61 9.5.1 Ready LED Out 61 9.5.2 Differential signals 61 10.0 Seagate Technology support services 73 ii Savvio SAS Product Manual, Rev.
Savvio 10K.1 SAS Product Manual
Page 7
Savvio drives support the SAS Protocol specifications to the extent described in this and other Seagate SAS drives. D 1 Figure 1. 1.0 Scope This manual describes Seagate Technology® LLC, Savvio® SAS (Serial Attached SCSI) disc drives. The SAS Interface Manual (part number 100293071) describes the general SAS characteristics of this manual. Savvio family disc drive Savvio SAS Product Manual, Rev.
Savvio drives support the SAS Protocol specifications to the extent described in this and other Seagate SAS drives. D 1 Figure 1. 1.0 Scope This manual describes Seagate Technology® LLC, Savvio® SAS (Serial Attached SCSI) disc drives. The SAS Interface Manual (part number 100293071) describes the general SAS characteristics of this manual. Savvio family disc drive Savvio SAS Product Manual, Rev.
Savvio 10K.1 SAS Product Manual
Page 13
... and related reliability concerns. Savvio SAS Product Manual, Rev. 3.0 General description Savvio drives combine Tunneling Magnetoresistive (TMR) heads and a Serial Attached SCSI (SAS) interface to support the Serial Attached SCSI Protocol as described in the ANSI specifications, this document, and the SAS Interface Manual (part number 100293071) which describes the general...
... and related reliability concerns. Savvio SAS Product Manual, Rev. 3.0 General description Savvio drives combine Tunneling Magnetoresistive (TMR) heads and a Serial Attached SCSI (SAS) interface to support the Serial Attached SCSI Protocol as described in the ANSI specifications, this document, and the SAS Interface Manual (part number 100293071) which describes the general...
Savvio 10K.1 SAS Product Manual
Page 14
...segmentable cache buffer • 300 Mbytes/sec maximum instantaneous data transfers. • 10k RPM spindle. D deep task set (queue) • Supports up to 32 initiators • Jumperless configuration. • User-selectable logical block size (512 to 528 bytes per logical block) in any...write and read reallocation • Reallocation of defects on command (Post Format) • ECC maximum burst correction length of queue • Supports start and stop commands (spindle stops spinning) • Adaptive seek velocity; Average latency = 3.0 msec • Background processing of 320 ...
...segmentable cache buffer • 300 Mbytes/sec maximum instantaneous data transfers. • 10k RPM spindle. D deep task set (queue) • Supports up to 32 initiators • Jumperless configuration. • User-selectable logical block size (512 to 528 bytes per logical block) in any...write and read reallocation • Reallocation of defects on command (Post Format) • ECC maximum burst correction length of queue • Supports start and stop commands (spindle stops spinning) • Adaptive seek velocity; Average latency = 3.0 msec • Background processing of 320 ...
Savvio 10K.1 SAS Product Manual
Page 20
... user-selectable configurations. The wrap-around capability of the individual segments greatly enhances the cache's overall performance, allowing a wide range of the segment. The drive supports operation of any segment of the operation; Default is used to force the drive to write all data received from this point. Note. The value...
... user-selectable configurations. The wrap-around capability of the individual segments greatly enhances the cache's overall performance, allowing a wide range of the segment. The drive supports operation of any segment of the operation; Default is used to force the drive to write all data received from this point. Note. The value...
Savvio 10K.1 SAS Product Manual
Page 45
...the recovery time limit. At factory format time, these known defects are listed in the "G" list (defects growth list). The error recovery scheme supported by the host (initiator). The total amount of defects found and reallocated during drive operation, the drive, if programmed to do not include ... by the read recoveries and five levels for the command has not yet been met. Each level may consist of the SCSI commands supported by the initiator using several SCSI commands described in the Error Recovery Parameters mode page. The times given do so, performs error recovery...
...the recovery time limit. At factory format time, these known defects are listed in the "G" list (defects growth list). The error recovery scheme supported by the host (initiator). The total amount of defects found and reallocated during drive operation, the drive, if programmed to do not include ... by the read recoveries and five levels for the command has not yet been met. Each level may consist of the SCSI commands supported by the initiator using several SCSI commands described in the Error Recovery Parameters mode page. The times given do so, performs error recovery...
Savvio 10K.1 SAS Product Manual
Page 51
Table 16: Task management response codes Function name Function complete Response code 00 Invalid frame 02 Function not supported 04 Function failed 05 Function succeeded 08 Invalid logical unit 09 Savvio SAS Product Manual, Rev. D 45 Additional ...9.1 SAS features This section lists the SAS-specific features supported by Savvio drives. 9.1.1 task management functions Table 15 lists the SAS task management functions supported. Table 15: SAS task management functions supported Task name Abort Task Clear ACA Supported Yes Yes Clear task set Yes Abort task set Yes...
Table 16: Task management response codes Function name Function complete Response code 00 Invalid frame 02 Function not supported 04 Function failed 05 Function succeeded 08 Invalid logical unit 09 Savvio SAS Product Manual, Rev. D 45 Additional ...9.1 SAS features This section lists the SAS-specific features supported by Savvio drives. 9.1.1 task management functions Table 15 lists the SAS task management functions supported. Table 15: SAS task management functions supported Task name Abort Task Clear ACA Supported Yes Yes Clear task set Yes Abort task set Yes...
Savvio 10K.1 SAS Product Manual
Page 52
... SAS drives have two independent ports. The two ports run at the same time. • Full duplex-The drive supports sending XFER_RDY, DATA and RESPONSE transfers while receiving frames on condition of allowing either link rate (1.5 or 3.0 Gbits/sec). The first port to ...successfully complete speed negotiation sets the link rate support by the first port. These ports may be connected in speed negotiation, it indicates the only supported speed is the speed selected by both ports. 46 Savvio SAS Product Manual, Rev. Subject to the...
... SAS drives have two independent ports. The two ports run at the same time. • Full duplex-The drive supports sending XFER_RDY, DATA and RESPONSE transfers while receiving frames on condition of allowing either link rate (1.5 or 3.0 Gbits/sec). The first port to ...successfully complete speed negotiation sets the link rate support by the first port. These ports may be connected in speed negotiation, it indicates the only supported speed is the speed selected by both ports. 46 Savvio SAS Product Manual, Rev. Subject to the...
Savvio 10K.1 SAS Product Manual
Page 53
... Savvio SAS family drive Command name Change Definition Compare Copy Copy and Verify Format Unit [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented ...Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD bit ETC...
... Savvio SAS family drive Command name Change Definition Compare Copy Copy and Verify Format Unit [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented ...Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD bit ETC...
Savvio 10K.1 SAS Product Manual
Page 54
... drive (continued) Command name Last n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) Self-test Results page (10h) Start-stop Cycle Counter page (0Eh) ... (same pages as Mode Sense 1Ah) Persistent Reserve In Persistent Reserve Out Prefetch Read (6) Read (10) DPO bit supported FUA bit supported Read (12) Read (16) Read (32) Read Buffer (modes 0, 2, 3, Ah and Bh supported) Command code 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h 7Fh/0009h 3Ch...
... drive (continued) Command name Last n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) Self-test Results page (10h) Start-stop Cycle Counter page (0Eh) ... (same pages as Mode Sense 1Ah) Persistent Reserve In Persistent Reserve Out Prefetch Read (6) Read (10) DPO bit supported FUA bit supported Read (12) Read (16) Read (32) Read Buffer (modes 0, 2, 3, Ah and Bh supported) Command code 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h 7Fh/0009h 3Ch...
Savvio 10K.1 SAS Product Manual
Page 55
... Read Capacity (16) Read Defect Data (10) Read Defect Data (12) Read Long Read Long (16) Reassign Blocks Receive Diagnostic Results Supported Diagnostics pages (00h) Translate page (40h) Release Release (10) Report LUNs Request Sense Actual Retry Count bytes Extended Sense Field Pointer bytes ... (10) 3rd Party Reserve Extent Reservation Rezero Unit Search Data Equal Search Data High Search Data Low Seek (6) Seek (10) Send Diagnostics Supported Diagnostics pages (00h) Translate page (40h) Set Limits Start Unit/Stop Unit (spindle ceases rotating) Synchronize Cache Synchronize Cache (16) Test ...
... Read Capacity (16) Read Defect Data (10) Read Defect Data (12) Read Long Read Long (16) Reassign Blocks Receive Diagnostic Results Supported Diagnostics pages (00h) Translate page (40h) Release Release (10) Report LUNs Request Sense Actual Retry Count bytes Extended Sense Field Pointer bytes ... (10) 3rd Party Reserve Extent Reservation Rezero Unit Search Data Equal Search Data High Search Data Low Seek (6) Seek (10) Send Diagnostics Supported Diagnostics pages (00h) Translate page (40h) Set Limits Start Unit/Stop Unit (spindle ceases rotating) Synchronize Cache Synchronize Cache (16) Test ...
Savvio 10K.1 SAS Product Manual
Page 56
... AFh 7Fh/000Ah 0Ah 2Ah AAh 8Ah 7Fh/000Bh 2Eh AEh 8Eh 7Fh/000Ch 3Bh 3Fh 9Fh/11h 41h 93h 7Fh/000Dh 52h 50h 51h Supported N N N Y Y Y Y N N N Y Y N N N Y Y Y N Y N N N N N N N [1] Savvio drives can result in the range 512 to any multiple of four bytes per logical block in ...firmware corruption. This usually makes the drive inoperable. [3] Reference Mode Sense command 1Ah for mode pages supported. [4] Y = Yes. Power loss during flash programming can format to 528 bytes. [2] Warning. Command is available on special request. 50 Savvio...
... AFh 7Fh/000Ah 0Ah 2Ah AAh 8Ah 7Fh/000Bh 2Eh AEh 8Eh 7Fh/000Ch 3Bh 3Fh 9Fh/11h 41h 93h 7Fh/000Dh 52h 50h 51h Supported N N N Y Y Y Y N N N Y Y N N N Y Y Y N Y N N N N N N N [1] Savvio drives can result in the range 512 to any multiple of four bytes per logical block in ...firmware corruption. This usually makes the drive inoperable. [3] Reference Mode Sense command 1Ah for mode pages supported. [4] Y = Yes. Power loss during flash programming can format to 528 bytes. [2] Warning. Command is available on special request. 50 Savvio...
Savvio 10K.1 SAS Product Manual
Page 61
...allegiance Asynchronous event notification Synchronized (locked) spindle operation Segmented caching Zero latency read Queue tagging (up to 64 queue tags supported) Deferred error handling Parameter rounding (controlled by Round bit in Mode Select page 0) Reporting actual retry count in Extended ...15, 16, and 17 Adaptive caching SMP = 1 in Mode Select command needed to save RPL and rotational offset bytes Table 22: Miscellaneous status Supported Y Y Y Y Y Y Y Y N N Status Good Check condition Condition met/good Busy Intermediate/good Intermediate/condition met/good Reservation conflict Task...
...allegiance Asynchronous event notification Synchronized (locked) spindle operation Segmented caching Zero latency read Queue tagging (up to 64 queue tags supported) Deferred error handling Parameter rounding (controlled by Round bit in Mode Select page 0) Reporting actual retry count in Extended ...15, 16, and 17 Adaptive caching SMP = 1 in Mode Select command needed to save RPL and rotational offset bytes Table 22: Miscellaneous status Supported Y Y Y Y Y Y Y Y N N Status Good Check condition Condition met/good Busy Intermediate/good Intermediate/condition met/good Reservation conflict Task...
Savvio 10K.1 SAS Product Manual
Page 66
... 12 Volts charge P14 12 Volts * P15 12 Volts * 9.4.6 SAS transmitters and receivers A typical SAS differential copper transmitter and receiver pair is AC coupling to support hot plugging NC - D SAS transmitters and receivers .01 RX Receiver 100 .01 RY 60 Savvio SAS Product Manual, Rev. input pair S3* -Port A_in S4...
... 12 Volts charge P14 12 Volts * P15 12 Volts * 9.4.6 SAS transmitters and receivers A typical SAS differential copper transmitter and receiver pair is AC coupling to support hot plugging NC - D SAS transmitters and receivers .01 RX Receiver 100 .01 RY 60 Savvio SAS Product Manual, Rev. input pair S3* -Port A_in S4...
Savvio 10K.1 SAS Product Manual
Page 71
... both the Tx+ and Tx- A.C. The OOB sequence is the maximum A.C. c The transmitter off voltage is performed at signal voltage levels corresponding to the lowest supported transfer rate. offset) component between the burst times and the idle times of an OOB signal). 9.5.2.2 Transmitter signal characteristics Table 27 specifies the signal requirements...
... both the Tx+ and Tx- A.C. The OOB sequence is the maximum A.C. c The transmitter off voltage is performed at signal voltage levels corresponding to the lowest supported transfer rate. offset) component between the burst times and the idle times of an OOB signal). 9.5.2.2 Transmitter signal characteristics Table 27 specifies the signal requirements...
Savvio 10K.1 SAS Product Manual
Page 79
.... Have your system configuration information and your specific application or computer system, as well as product availability and compatibility. You can help you online at support.seagate.com or through a single, password-protected Web interface-anytime, anywhere in the world. It provides self-service access to critical applications, personalized content and the...
.... Have your system configuration information and your specific application or computer system, as well as product availability and compatibility. You can help you online at support.seagate.com or through a single, password-protected Web interface-anytime, anywhere in the world. It provides self-service access to critical applications, personalized content and the...
Savvio 10K.1 SAS Product Manual
Page 80
... the world. . Contact your serial number and model or part number available. Asia/Pacific Support Services For an extensive list of purchase or Seagate warranty service for warrantyrelated issues. Seagate distributors, OEMs and other direct customers should contact their Seagate Customer Service Operations (CSO) representative for assistance. Our data recovery services labs are available...
... the world. . Contact your serial number and model or part number available. Asia/Pacific Support Services For an extensive list of purchase or Seagate warranty service for warrantyrelated issues. Seagate distributors, OEMs and other direct customers should contact their Seagate Customer Service Operations (CSO) representative for assistance. Our data recovery services labs are available...
Savvio 10K.1 SAS Product Manual
Page 81
...11 case temperature 32 check condition status 55 class B limit 3 clear ACA function 45 clear task set function 45 commands supported 47 condensation 32 condition met/good status 55 connector illustrated 59 requirements 59 continuous vibration 35 cooling 42 CRC error 18 Current...speed 11 drive 35 drive characteristics 11 drive failure 18 drive malfunction 18 drive mounting 37, 43 drive select 59 dual port support 46 E electrical description of connector 59 signal characteristics 61 specifications 25 electromagnetic compatibility 3 electromagnetic susceptibility 36 EMI requirements 3 environment ...
...11 case temperature 32 check condition status 55 class B limit 3 clear ACA function 45 clear task set function 45 commands supported 47 condensation 32 condition met/good status 55 connector illustrated 59 requirements 59 continuous vibration 35 cooling 42 CRC error 18 Current...speed 11 drive 35 drive characteristics 11 drive failure 18 drive malfunction 18 drive mounting 37, 43 drive select 59 dual port support 46 E electrical description of connector 59 signal characteristics 61 specifications 25 electromagnetic compatibility 3 electromagnetic susceptibility 36 EMI requirements 3 environment ...
Savvio 10K.1 SAS Product Manual
Page 82
...43 head and disc assembly (HDA) 7 head and disc assembly. See MTBF media description 8 minimum sector interleave 12 miscellaneous feature support Adaptive caching 55 Asynchronous event notification 55 Automatic contingent allegiance 55 Deferred error handling 55 Parameter rounding 55 Queue tagging 55 Reporting actual ...equipment 43 hot plugging the drive 19 humidity 32 humidity limits 32 I inquiry data 51 installation 41 guide 5 interface commands supported 47 error rate 17 errors 18 illustrated 56 physical 56 requirements 45 interleave minimum 12 intermediate/condition met/good status 55 ...
...43 head and disc assembly (HDA) 7 head and disc assembly. See MTBF media description 8 minimum sector interleave 12 miscellaneous feature support Adaptive caching 55 Asynchronous event notification 55 Automatic contingent allegiance 55 Deferred error handling 55 Parameter rounding 55 Queue tagging 55 Reporting actual ...equipment 43 hot plugging the drive 19 humidity 32 humidity limits 32 I inquiry data 51 installation 41 guide 5 interface commands supported 47 error rate 17 errors 18 illustrated 56 physical 56 requirements 45 interleave minimum 12 intermediate/condition met/good status 55 ...
Savvio 10K.1 SAS Product Manual
Page 83
... return information 24 rotation speed 11 S safety 3 SAS interface 59 physical interface 56 task management functions 45 SAS documents 5 SAS Interface Manual 3, 5 SCSI interface commands supported 47 seek error defined 18 rate 17 seek performance characteristics 11 seek time average typical 11 full stroke typical 11 single track typical 11 segmented...
... return information 24 rotation speed 11 S safety 3 SAS interface 59 physical interface 56 task management functions 45 SAS documents 5 SAS Interface Manual 3, 5 SCSI interface commands supported 47 seek error defined 18 rate 17 seek performance characteristics 11 seek time average typical 11 full stroke typical 11 single track typical 11 segmented...