Pulsar.2 SAS Product Manual
Page 3
B i Contents 1.0 2.0 3.0 Seagate Technology support services ...1 Scope...2 Applicable standards and reference documentation ...3.1 Standards ...3.1.1 Electromagnetic compatibility...3.1.2 Electromagnetic compliance ...3.1.3 European Union Restriction of Hazardous Substances (RoHS) ...3.1.4 China Restriction of Hazardous Substances (RoHS) ...
B i Contents 1.0 2.0 3.0 Seagate Technology support services ...1 Scope...2 Applicable standards and reference documentation ...3.1 Standards ...3.1.1 Electromagnetic compatibility...3.1.2 Electromagnetic compliance ...3.1.3 European Union Restriction of Hazardous Substances (RoHS) ...3.1.4 China Restriction of Hazardous Substances (RoHS) ...
Pulsar.2 SAS Product Manual
Page 4
... ...9.1 Data encryption ...9.2 Controlled access...9.2.1 Admin SP ...9.2.2 Locking SP ...9.2.3 Default password ...9.3 Random number generator (RNG)...9.4 Drive locking...9.5 Data bands...9.6 Cryptographic erase...9.7 Authenticated firmware download ...9.8 Power requirements ...9.9 Supported commands ...9.10 Sanitize - B
... ...9.1 Data encryption ...9.2 Controlled access...9.2.1 Admin SP ...9.2.2 Locking SP ...9.2.3 Default password ...9.3 Random number generator (RNG)...9.4 Drive locking...9.5 Data bands...9.6 Cryptographic erase...9.7 Authenticated firmware download ...9.8 Power requirements ...9.9 Supported commands ...9.10 Sanitize - B
Pulsar.2 SAS Product Manual
Page 9
.../www/en-us/about/contact_us/ Available services include: Presales & Technical support Global Support Services telephone numbers & business hours Authorized Service Centers Warranty terms will vary based on type of warranty chosen: "Managed Life" or "Usage Based". 1.0 Seagate Technology support services SEAGATE ONLINE SUPPORT and SERVICES For information regarding Data Recovery Services, visit http://www.i365.com...
.../www/en-us/about/contact_us/ Available services include: Presales & Technical support Global Support Services telephone numbers & business hours Authorized Service Centers Warranty terms will vary based on type of warranty chosen: "Managed Life" or "Usage Based". 1.0 Seagate Technology support services SEAGATE ONLINE SUPPORT and SERVICES For information regarding Data Recovery Services, visit http://www.i365.com...
Pulsar.2 SAS Product Manual
Page 10
... provisions for "Security of future generation specifications or requirements. Pulsar.2 drives support the SAS Protocol specifications to the extent described in this manual is specific... SAS characteristics of encryption was necessary. Standard models ST800FM0002 ST800FM0032 ST400FM0002 ST400FM0042 ST200FM0002 ST200FM0042 ST100FM0002 ST100FM0052 Standard SED models ST800FM0012 ST800FM0042 FIPS 140-2 Level 2 (Review Pending)...) models before a differentiation between drive-based encryption and other Seagate SAS drives. Note. Unless otherwise stated, the information in...
... provisions for "Security of future generation specifications or requirements. Pulsar.2 drives support the SAS Protocol specifications to the extent described in this manual is specific... SAS characteristics of encryption was necessary. Standard models ST800FM0002 ST800FM0032 ST400FM0002 ST400FM0042 ST200FM0002 ST200FM0042 ST100FM0002 ST100FM0052 Standard SED models ST800FM0012 ST800FM0042 FIPS 140-2 Level 2 (Review Pending)...) models before a differentiation between drive-based encryption and other Seagate SAS drives. Note. Unless otherwise stated, the information in...
Pulsar.2 SAS Product Manual
Page 14
... have the following standard features: 1.5 / 3.0 / 6.0 Gb Serial Attached SCSI (SAS) interface Integrated dual port SAS controller supporting the SCSI protocol Support for a variety of Data at Rest" based on the standards defined by the Trusted Computing Group (see www.trustedcomputinggroup.org). ....2 drives are compatible with Serial ATA (SATA), giving future users the choice of populating their systems with Block Unmap Support Silent operation Lifetime Endurance Management (available on the cover of 96 bits No preventive maintenance or adjustments required Self diagnostics performed...
... have the following standard features: 1.5 / 3.0 / 6.0 Gb Serial Attached SCSI (SAS) interface Integrated dual port SAS controller supporting the SCSI protocol Support for a variety of Data at Rest" based on the standards defined by the Trusted Computing Group (see www.trustedcomputinggroup.org). ....2 drives are compatible with Serial ATA (SATA), giving future users the choice of populating their systems with Block Unmap Support Silent operation Lifetime Endurance Management (available on the cover of 96 bits No preventive maintenance or adjustments required Self diagnostics performed...
Pulsar.2 SAS Product Manual
Page 17
...in SSD products because it are defined as needed. Thin Provisioning Product Configuration Table 2: Product Configuration Non-SED SED LBPME Supported Supported LBPRZ Supported Not Supported A logical block provisioning management enabled (LBPME) bit set to Physical Blocks by a previous WRITE command. 4.8 4.8.1 Thin... Physical Block, thereby freeing up the Physical Block from use of Thin Provisioning is an increase in the Seagate SCSI Command Reference 100293068.. Support of the Thin Provisioning model. Thin Provisioning and the READ CAPACITY 16 (9Eh) command is a technique ...
...in SSD products because it are defined as needed. Thin Provisioning Product Configuration Table 2: Product Configuration Non-SED SED LBPME Supported Supported LBPRZ Supported Not Supported A logical block provisioning management enabled (LBPME) bit set to Physical Blocks by a previous WRITE command. 4.8 4.8.1 Thin... Physical Block, thereby freeing up the Physical Block from use of Thin Provisioning is an increase in the Seagate SCSI Command Reference 100293068.. Support of the Thin Provisioning model. Thin Provisioning and the READ CAPACITY 16 (9Eh) command is a technique ...
Pulsar.2 SAS Product Manual
Page 21
... 2006.7.27. B 13 IOMeter is defined as mentioned and host commands are aligned on 4KB boundaries. For models that support Lifetime Endurance Management, write values also take into account the worst case performance throttling that the product will be able to... Public License. Pulsar.2 SAS Product Manual, Rev. 5.2.3 Table 6: Performance Performance (Managed Life Warranty) Notes ST800FM0002 ST800FM0012 ST800FM0022 ST400FM0002 ST200FM0002 ST100FM0002 Maximum Burst Transfer Rate Peak sequential 128KB read/write data transfer rate (MB/s max) Sustained sequential 128KB read/ write data ...
... 2006.7.27. B 13 IOMeter is defined as mentioned and host commands are aligned on 4KB boundaries. For models that support Lifetime Endurance Management, write values also take into account the worst case performance throttling that the product will be able to... Public License. Pulsar.2 SAS Product Manual, Rev. 5.2.3 Table 6: Performance Performance (Managed Life Warranty) Notes ST800FM0002 ST800FM0012 ST800FM0022 ST400FM0002 ST200FM0002 ST100FM0002 Maximum Burst Transfer Rate Peak sequential 128KB read/write data transfer rate (MB/s max) Sustained sequential 128KB read/ write data ...
Pulsar.2 SAS Product Manual
Page 31
... the factory seal voids the warranty. During any third-party repair facilities. B 23 Seagate recommends shipping by the Seagate Approved Package label. Drives should be stored in transit. 6.3.7 Product warranty See Section 1.0, "Seagate Technology support services" for the drive in section 6.2.6. Seagate approved containers are the only facilities authorized to purchase additional boxes. Product repair...
... the factory seal voids the warranty. During any third-party repair facilities. B 23 Seagate recommends shipping by the Seagate Approved Package label. Drives should be stored in transit. 6.3.7 Product warranty See Section 1.0, "Seagate Technology support services" for the drive in section 6.2.6. Seagate approved containers are the only facilities authorized to purchase additional boxes. Product repair...
Pulsar.2 SAS Product Manual
Page 52
... ERASE is a SCSI CDB Op code 48h and selecting the service action code 3 (CRYPTOGRAPHIC ERASE). 9.11 RevertSP SED models will support the RevertSP feature which have identical hardware, however the security and encryption portion of the drive controller ASIC is not electronically accessible and can...prevent unwanted firmware download attempts, the drive also only accepts download files which erases all user data on the drive by the appropriate Seagate Design Center. The download must be met before the drive will be signed and authenticated. 3. As with a new data encryption key...
... ERASE is a SCSI CDB Op code 48h and selecting the service action code 3 (CRYPTOGRAPHIC ERASE). 9.11 RevertSP SED models will support the RevertSP feature which have identical hardware, however the security and encryption portion of the drive controller ASIC is not electronically accessible and can...prevent unwanted firmware download attempts, the drive also only accepts download files which erases all user data on the drive by the appropriate Seagate Design Center. The download must be met before the drive will be signed and authenticated. 3. As with a new data encryption key...
Pulsar.2 SAS Product Manual
Page 53
... channel number within the corresponding Flash Controller. Details of the 110b format is defined in the defects reallocation table. The definition of the SCSI commands supported by the initiator using the READ DEFECT DATA command. Table 13: Bit Byte 0 1 2 3 4 5 6 7 SSD Physical format address descriptor 7 (MSB) 6 5...errors in the SAS Interface Manual. The drive uses a vendor unique format to manage defects and errors. In addition, Seagate provides the following table. Locations of a format for devices that is defined as being unusable, and their locations recorded ...
... channel number within the corresponding Flash Controller. Details of the 110b format is defined in the defects reallocation table. The definition of the SCSI commands supported by the initiator using the READ DEFECT DATA command. Table 13: Bit Byte 0 1 2 3 4 5 6 7 SSD Physical format address descriptor 7 (MSB) 6 5...errors in the SAS Interface Manual. The drive uses a vendor unique format to manage defects and errors. In addition, Seagate provides the following table. Locations of a format for devices that is defined as being unusable, and their locations recorded ...
Pulsar.2 SAS Product Manual
Page 55
...with PI information bytes. Provides support of 32 byte commands. Eight bytes of PI being transferred from the media that typically does not support 520 LBA formats to SCSI Block Commands - 3 (SBC-3) Draft Standard documentation. Seagate products do not support Type 3. 10.6.2 Setting and ...determining the current Type Level A drive is initialized to indicate the PI Types supported and which PI fields the drive supports checking. It can only be reduced by the T10...
...with PI information bytes. Provides support of 32 byte commands. Eight bytes of PI being transferred from the media that typically does not support 520 LBA formats to SCSI Block Commands - 3 (SBC-3) Draft Standard documentation. Seagate products do not support Type 3. 10.6.2 Setting and ...determining the current Type Level A drive is initialized to indicate the PI Types supported and which PI fields the drive supports checking. It can only be reduced by the T10...
Pulsar.2 SAS Product Manual
Page 59
...Clear ACA Clear task set I_T Nexus Reset Logical Unit Reset Query Task Query Task Set Query Asynchronous Event SAS task management functions supported Supported Yes Yes Yes Yes Yes Yes Yes Yes Yes 12.1.2 Task management responses Table 15 lists the SAS response codes returned for ....2 drives. Table 15: Task management response codes Response code 00 02 04 05 08 09 Function name Function complete Invalid frame Function not supported Function failed Function succeeded Invalid logical unit Pulsar.2 SAS Product Manual, Rev. B 51 Additional information is provided in the SAS Interface Manual ...
...Clear ACA Clear task set I_T Nexus Reset Logical Unit Reset Query Task Query Task Set Query Asynchronous Event SAS task management functions supported Supported Yes Yes Yes Yes Yes Yes Yes Yes Yes 12.1.2 Task management responses Table 15 lists the SAS response codes returned for ....2 drives. Table 15: Task management response codes Response code 00 02 04 05 08 09 Function name Function complete Invalid frame Function not supported Function failed Function succeeded Invalid logical unit Pulsar.2 SAS Product Manual, Rev. B 51 Additional information is provided in the SAS Interface Manual ...
Pulsar.2 SAS Product Manual
Page 60
.... Each drive port has a unique SAS address. Subject to buffer availability, the Pulsar.2 drives support: • Concurrent port transfers-The drive supports receiving COMMAND, TASK management transfers on both ports at 3Gb/s.) The supported link rates are 1.5, 3.0, or 6.0 Gb/s. both ports can run at 6Gb/s or the ...first port can run at 6Gb/s while the second port runs at the same time. • Full duplex-The drive supports sending XFER_RDY, DATA and RESPONSE transfers while receiving frames on both ports. 52 Pulsar.2 SAS Product Manual, Rev. The two ports have ...
.... Each drive port has a unique SAS address. Subject to buffer availability, the Pulsar.2 drives support: • Concurrent port transfers-The drive supports receiving COMMAND, TASK management transfers on both ports at 3Gb/s.) The supported link rates are 1.5, 3.0, or 6.0 Gb/s. both ports can run at 6Gb/s or the ...first port can run at 6Gb/s while the second port runs at the same time. • Full duplex-The drive supports sending XFER_RDY, DATA and RESPONSE transfers while receiving frames on both ports. 52 Pulsar.2 SAS Product Manual, Rev. The two ports have ...
Pulsar.2 SAS Product Manual
Page 61
... name CHANGE DEFINITION FORMAT UNIT [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) INQUIRY Block Limits page (B0h) Block Device Characteristics page (B1h) Date Code page (C1h) Device Behavior page (C3h...) Device Identification page (83h) Extended Inquiry Data page (86h) Firmware Numbers page (C0h) Jumper Settings page (C2h) Power Conditions page (8Ah) Supported Vital Product Data page (00h) Thin Provisioning page (B2h) Unit Serial Number page (80h) Vendor Unique page (D1h) Vendor Unique page (D2h) LOG ...
... name CHANGE DEFINITION FORMAT UNIT [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) INQUIRY Block Limits page (B0h) Block Device Characteristics page (B1h) Date Code page (C1h) Device Behavior page (C3h...) Device Identification page (83h) Extended Inquiry Data page (86h) Firmware Numbers page (C0h) Jumper Settings page (C2h) Power Conditions page (8Ah) Supported Vital Product Data page (00h) Thin Provisioning page (B2h) Unit Serial Number page (80h) Vendor Unique page (D1h) Vendor Unique page (D2h) LOG ...
Pulsar.2 SAS Product Manual
Page 62
... n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Protocol-Specific Port log pages (18h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) ... Control page (10h) MODE SENSE (10) (same pages as MODE SENSE (6)) PERSISTENT RESERVE IN PERSISTENT RESERVE OUT PRE-FETCH (10) READ (6) READ (10) DPO bit supported FUA bit supported READ (12) READ (16) 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h N N Y Y Y Y N Y Y Y Y Y Y Y Y [3] Y Y [3] Y Y Y Y N Y Y N Y Y Y N Y Y N Y Y Y N Y Y Y Y ...
... n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Protocol-Specific Port log pages (18h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) ... Control page (10h) MODE SENSE (10) (same pages as MODE SENSE (6)) PERSISTENT RESERVE IN PERSISTENT RESERVE OUT PRE-FETCH (10) READ (6) READ (10) DPO bit supported FUA bit supported READ (12) READ (16) 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h N N Y Y Y Y N Y Y Y Y Y Y Y Y [3] Y Y [3] Y Y Y Y N Y Y N Y Y Y N Y Y N Y Y Y N Y Y Y Y ...
Pulsar.2 SAS Product Manual
Page 63
... (16) READ DEFECT DATA (10) READ DEFECT DATA (12) READ LONG (10) READ LONG (16) REASSIGN BLOCKS RECEIVE DIAGNOSTIC RESULTS Supported Diagnostics pages (00h) Translate page (40h) RELEASE (6) RELEASE (10) REPORT LUNS REQUEST SENSE Actual Retry Count bytes Extended Sense Field Pointer bytes... Extent Reservation REZERO UNIT SANITIZE Overwrite Block Erase Cryptographic Erase SECURITY PROTOCOL IN SECURITY PROTOCOL OUT SEEK (6) SEEK (10) SEND DIAGNOSTICS Supported Diagnostics pages (00h) Translate page (40h) START UNIT/STOP UNIT SYNCHRONIZE CACHE SYNCHRONIZE CACHE (16) TEST UNIT READY UNMAP 7Fh/...
... (16) READ DEFECT DATA (10) READ DEFECT DATA (12) READ LONG (10) READ LONG (16) REASSIGN BLOCKS RECEIVE DIAGNOSTIC RESULTS Supported Diagnostics pages (00h) Translate page (40h) RELEASE (6) RELEASE (10) REPORT LUNS REQUEST SENSE Actual Retry Count bytes Extended Sense Field Pointer bytes... Extent Reservation REZERO UNIT SANITIZE Overwrite Block Erase Cryptographic Erase SECURITY PROTOCOL IN SECURITY PROTOCOL OUT SEEK (6) SEEK (10) SEND DIAGNOSTICS Supported Diagnostics pages (00h) Translate page (40h) START UNIT/STOP UNIT SYNCHRONIZE CACHE SYNCHRONIZE CACHE (16) TEST UNIT READY UNMAP 7Fh/...
Pulsar.2 SAS Product Manual
Page 64
... block. Command is available on special request. 56 Pulsar.2 SAS Product Manual, Rev. Command is not supported. This usually makes the drive inoperable. Table 16: Supported commands Command code Supported Command name VERIFY (10) BYTCHK bit VERIFY (12) VERIFY (16) VERIFY (32) WRITE (6) WRITE...WRITE (32) WRITE AND VERIFY (10) DPO bit WRITE AND VERIFY (12) WRITE AND VERIFY (16) WRITE AND VERIFY (32) WRITE BUFFER (modes 0, 2, supported) WRITE BUFFER Firmware Download option (modes 5, 7, Ah and Bh) [2] Firmware Download option (modes 4, 5, 7) WRITE LONG (10) WRITE LONG (16) WRITE ...
... block. Command is available on special request. 56 Pulsar.2 SAS Product Manual, Rev. Command is not supported. This usually makes the drive inoperable. Table 16: Supported commands Command code Supported Command name VERIFY (10) BYTCHK bit VERIFY (12) VERIFY (16) VERIFY (32) WRITE (6) WRITE...WRITE (32) WRITE AND VERIFY (10) DPO bit WRITE AND VERIFY (12) WRITE AND VERIFY (16) WRITE AND VERIFY (32) WRITE BUFFER (modes 0, 2, supported) WRITE BUFFER Firmware Download option (modes 5, 7, Ah and Bh) [2] Firmware Download option (modes 4, 5, 7) WRITE LONG (10) WRITE LONG (16) WRITE ...
Pulsar.2 SAS Product Manual
Page 65
... 32 ST400FM0002 53 54 34 30 30 46 4D 30 30 30 32 ST400FM0042 53 54 34 30 30 46 4D 30 30 34 32 ST200FM0002 53 54 32 30 30 46 4D 30 30 30 32 ST200FM0042 53 54 32 30 30 46 4D 30 30 34 32 ST100FM0002 53.... 10 = INQUIRY data for an INQUIRY command received on Port B. Refer to the initiator per the format given in the SAS Interface Manual. SCSI Revision support.
... 32 ST400FM0002 53 54 34 30 30 46 4D 30 30 30 32 ST400FM0042 53 54 34 30 30 46 4D 30 30 34 32 ST200FM0002 53 54 32 30 30 46 4D 30 30 30 32 ST200FM0042 53 54 32 30 30 46 4D 30 30 34 32 ST100FM0002 53.... 10 = INQUIRY data for an INQUIRY command received on Port B. Refer to the initiator per the format given in the SAS Interface Manual. SCSI Revision support.
Pulsar.2 SAS Product Manual
Page 71
... aspects of the SAS connector. An "N" in the SAS Interface Manual. Figures 18 and 19 provide the dimensions of Seagate's SAS drives are provided within this section. 12.4 Miscellaneous operating features and conditions Table 22 lists various features and conditions.... B 63 Physical interface Pulsar.2 SAS Product Manual, Rev. Figure 17. A "Y" in Extended Sense bytes 15, 16, and 17 Table 23: Supported Y Y Y Y Y Y N N N Miscellaneous status Status Good Check condition Condition met/good Busy Reservation conflict Task set full ACA active ACA active, faulted...
... aspects of the SAS connector. An "N" in the SAS Interface Manual. Figures 18 and 19 provide the dimensions of Seagate's SAS drives are provided within this section. 12.4 Miscellaneous operating features and conditions Table 22 lists various features and conditions.... B 63 Physical interface Pulsar.2 SAS Product Manual, Rev. Figure 17. A "Y" in Extended Sense bytes 15, 16, and 17 Table 23: Supported Y Y Y Y Y Y N N N Miscellaneous status Status Good Check condition Condition met/good Busy Reservation conflict Task set full ACA active ACA active, faulted...
Pulsar.2 SAS Product Manual
Page 74
... 19. 12.4.4 Electrical description SAS drives use the device connector for: • DC power • SAS interface • Activity LED This connector is designed to support hot plugging NC - No connection in the drive. 66 Pulsar.2 SAS Product Manual, Rev. Part numbers for mating part information. input pair P9* P10 P11...
... 19. 12.4.4 Electrical description SAS drives use the device connector for: • DC power • SAS interface • Activity LED This connector is designed to support hot plugging NC - No connection in the drive. 66 Pulsar.2 SAS Product Manual, Rev. Part numbers for mating part information. input pair P9* P10 P11...