Constellation ES.2 SAS Product Manual
Page 3
Contents 1.0 Seagate Technology support services 1 2.0 Scope 2 3.0 Applicable standards and reference documentation 3 3.1 Standards 3 3.1.1 Electromagnetic compatibility 3 3.1.2 Electromagnetic compliance 4 3.1.3 European Union Restriction of Hazardous Substances (RoHS 5 3.1.4 China Restriction of Hazardous Substances (RoHS) ...
Contents 1.0 Seagate Technology support services 1 2.0 Scope 2 3.0 Applicable standards and reference documentation 3 3.1 Standards 3 3.1.1 Electromagnetic compatibility 3 3.1.2 Electromagnetic compliance 4 3.1.3 European Union Restriction of Hazardous Substances (RoHS 5 3.1.4 China Restriction of Hazardous Substances (RoHS) ...
Constellation ES.2 SAS Product Manual
Page 4
...generator (RNG 36 9.4 Drive locking 36 9.5 Data bands 36 9.6 Cryptographic erase 36 9.7 Authenticated firmware download 37 9.8 Power requirements 37 9.9 Supported commands 37 9.10 RevertSP 37 10.0 Defect and error management 38 10.1 Drive internal defects/errors 38 10.2 Drive error recovery procedures 38...45 12.1 SAS features 45 12.1.1 task management functions 45 12.1.2 task management responses 45 12.2 Dual port support 46 12.3 SCSI commands supported 47 12.3.1 Inquiry data 51 12.3.2 Mode Sense data 51 12.4 Miscellaneous operating features and conditions 54 ii ...
...generator (RNG 36 9.4 Drive locking 36 9.5 Data bands 36 9.6 Cryptographic erase 36 9.7 Authenticated firmware download 37 9.8 Power requirements 37 9.9 Supported commands 37 9.10 RevertSP 37 10.0 Defect and error management 38 10.1 Drive internal defects/errors 38 10.2 Drive error recovery procedures 38...45 12.1 SAS features 45 12.1.1 task management functions 45 12.1.2 task management responses 45 12.2 Dual port support 46 12.3 SCSI commands supported 47 12.3.1 Inquiry data 51 12.3.2 Mode Sense data 51 12.4 Miscellaneous operating features and conditions 54 ii ...
Constellation ES.2 SAS Product Manual
Page 9
... SERVICES For information regarding products and services, visit http://www.seagate.com/www/en-us/about/contact_us/ Available services include: Presales & Technical support Global Support Services telephone numbers & business hours Authorized Service Centers For information regarding Warranty Support, visit http://www.seagate.com/www/en-us/support/warranty_&_returns_assistance For information regarding Data Recovery Services, visit...
... SERVICES For information regarding products and services, visit http://www.seagate.com/www/en-us/about/contact_us/ Available services include: Presales & Technical support Global Support Services telephone numbers & business hours Authorized Service Centers For information regarding Warranty Support, visit http://www.seagate.com/www/en-us/support/warranty_&_returns_assistance For information regarding Data Recovery Services, visit...
Constellation ES.2 SAS Product Manual
Page 10
...of the models listed or future generation products and need further assistance, please contact your Field Applications Engineer (FAE) or our global support services group as shown in this manual. C Model Number ST33000650SS ST33000651SS ST33000652SS Self-Encrypting Drive (SED) No Yes Yes FIPS 140... in this and other forms of this manual is specific only to standard and Self-Encrypting Drive models. 2.0 Scope This manual describes Seagate Technology® LLC, Constellation® ES.2 SAS (Serial Attached SCSI) disk drives. The SAS Interface Manual (part number 100293071) ...
...of the models listed or future generation products and need further assistance, please contact your Field Applications Engineer (FAE) or our global support services group as shown in this manual. C Model Number ST33000650SS ST33000651SS ST33000652SS Self-Encrypting Drive (SED) No Yes Yes FIPS 140... in this and other forms of this manual is specific only to standard and Self-Encrypting Drive models. 2.0 Scope This manual describes Seagate Technology® LLC, Constellation® ES.2 SAS (Serial Attached SCSI) disk drives. The SAS Interface Manual (part number 100293071) ...
Constellation ES.2 SAS Product Manual
Page 15
... classified as this product manual have provisions for a variety of the media to the ramp load/unload when power is applied to support the Serial Attached SCSI Protocol as described in the data zone. Constellation ES.2 drives are compatible with Serial ATA (SATA), giving ... Data at Rest" based on each surface to leverage your warranty. The drives also use a dedicated load/unload zone at the factory. Seagate recommends validating your configuration with minimal power dissipation. Constellation ES.2 SAS Product Manual, Rev. The head and disk assembly (HDA) is designed...
... classified as this product manual have provisions for a variety of the media to the ramp load/unload when power is applied to support the Serial Attached SCSI Protocol as described in the data zone. Constellation ES.2 drives are compatible with Serial ATA (SATA), giving ... Data at Rest" based on each surface to leverage your warranty. The drives also use a dedicated load/unload zone at the factory. Seagate recommends validating your configuration with minimal power dissipation. Constellation ES.2 SAS Product Manual, Rev. The head and disk assembly (HDA) is designed...
Constellation ES.2 SAS Product Manual
Page 16
... technology • 1.5 / 3.0 / 6.0 Gb Serial Attached SCSI (SAS) interface • Integrated dual port SAS controller supporting the SCSI protocol • Support for improved durability and environmental protection. 4.3 Performance • Programmable multi-segmentable cache buffer • 600MB/s maximum instantaneous data ... write and read reallocation • Reallocation of queue • Supports start and stop commands (spindle stops spinning) • Adaptive seek velocity; C deep task set (queue) • Supports up to the drive • Vertical, horizontal, or top down...
... technology • 1.5 / 3.0 / 6.0 Gb Serial Attached SCSI (SAS) interface • Integrated dual port SAS controller supporting the SCSI protocol • Support for improved durability and environmental protection. 4.3 Performance • Programmable multi-segmentable cache buffer • 600MB/s maximum instantaneous data ... write and read reallocation • Reallocation of queue • Supports start and stop commands (spindle stops spinning) • Adaptive seek velocity; C deep task set (queue) • Supports up to the drive • Vertical, horizontal, or top down...
Constellation ES.2 SAS Product Manual
Page 29
... Description Idle_A Reduced electronics Idle_B Heads unloaded. Standby_Z Heads unloaded. PowerChoiceTM can be invoked using the load/unload architecture provide programmable power management to any supported PowerChoice mode. Constellation ES.2 SAS Product Manual, Rev. Disks spinning at reduced RPM Standby_Y Heads unloaded. Motor stopped (disks not spinning) Recovery requires the NOTIFY...methods: • Power Condition mode page method-Enable and initialize the idle condition timers and/or the standby condition timers. The table below lists the supported PowerChoice modes.
... Description Idle_A Reduced electronics Idle_B Heads unloaded. Standby_Z Heads unloaded. PowerChoiceTM can be invoked using the load/unload architecture provide programmable power management to any supported PowerChoice mode. Constellation ES.2 SAS Product Manual, Rev. Disks spinning at reduced RPM Standby_Y Heads unloaded. Motor stopped (disks not spinning) Recovery requires the NOTIFY...methods: • Power Condition mode page method-Enable and initialize the idle condition timers and/or the standby condition timers. The table below lists the supported PowerChoice modes.
Constellation ES.2 SAS Product Manual
Page 30
... conditions enabled / disabled • Idle condition timer values (100ms increments) (default, saved, current, changeable) Power Condition Vital Product Data (VPD) Page (VPD page 0x8A) • Supported power conditions • Typical recovery time from power conditions (1ms increments) Start/Stop Cycle Counter Log Page reports (log page 0x0E) • Specified and accumulated...
... conditions enabled / disabled • Idle condition timer values (100ms increments) (default, saved, current, changeable) Power Condition Vital Product Data (VPD) Page (VPD page 0x8A) • Supported power conditions • Typical recovery time from power conditions (1ms increments) Start/Stop Cycle Counter Log Page reports (log page 0x0E) • Specified and accumulated...
Constellation ES.2 SAS Product Manual
Page 45
...of about 30mA and a commensurate increase of the drive controller ASIC is enabled and functional in addition to the commands supported by the appropriate Seagate Design Center. This represents a small additional drain on the 12V supply. 9.7 Authenticated firmware download In addition to providing...consumption. Three conditions must pass the acceptance criteria for power requirements on the standard (non-SED) drive models. 9.9 Supported commands The SED models support the following two commands in the SED models. There is no additional drain on the 5V supply of about 150mW ...
...of about 30mA and a commensurate increase of the drive controller ASIC is enabled and functional in addition to the commands supported by the appropriate Seagate Design Center. This represents a small additional drain on the 12V supply. 9.7 Authenticated firmware download In addition to providing...consumption. Three conditions must pass the acceptance criteria for power requirements on the standard (non-SED) drive models. 9.9 Supported commands The SED models support the following two commands in the SED models. There is no additional drain on the 5V supply of about 150mW ...
Constellation ES.2 SAS Product Manual
Page 46
... as being unusable, and their locations recorded on the options previously set in the Error Recovery mode page. In addition, Seagate provides the following technologies used depend on the drive primary defects list (referred to control the total error recovery time for the...and "G" lists may involve using the Read Defect Data command. The error recovery scheme supported by the drive are designed to controlling the recovery level for write. 10.0 Defect and error management Seagate continues to use innovative technologies to increase data integrity and drive reliability: • ...
... as being unusable, and their locations recorded on the options previously set in the Error Recovery mode page. In addition, Seagate provides the following technologies used depend on the drive primary defects list (referred to control the total error recovery time for the...and "G" lists may involve using the Read Defect Data command. The error recovery scheme supported by the drive are designed to controlling the recovery level for write. 10.0 Defect and error management Seagate continues to use innovative technologies to increase data integrity and drive reliability: • ...
Constellation ES.2 SAS Product Manual
Page 49
...and WRTPROTECT bits allow the use of Protection Information are transmitted at anytime to indicate if PI is support by using the format command on the drive. Seagate products do not support Type 3. 10.8.2 Setting and determining the current Type Level A drive is formatted to a PI...drive is initialized to . The drive will generate 8 bytes (e.g.0xFFFF) 8 bytes of PI protection using 520 byte formatted LBAs. Provides support of Protection Information to be queried by approximately 1.56% due to the extra overhead of protection. For further details with zero values in...
...and WRTPROTECT bits allow the use of Protection Information are transmitted at anytime to indicate if PI is support by using the format command on the drive. Seagate products do not support Type 3. 10.8.2 Setting and determining the current Type Level A drive is formatted to a PI...drive is initialized to . The drive will generate 8 bytes (e.g.0xFFFF) 8 bytes of PI protection using 520 byte formatted LBAs. Provides support of Protection Information to be queried by approximately 1.56% due to the extra overhead of protection. For further details with zero values in...
Constellation ES.2 SAS Product Manual
Page 53
... Yes Yes Yes Yes Yes 12.1.2 task management responses Table 5 lists the SAS response codes returned for task management functions supported. 12.0 Interface requirements This section partially describes the interface requirements as implemented on Constellation ES.2 drives. C 45 Table 5: Task ...management response codes Function name Function complete Invalid frame Function not supported Function failed Function succeeded Invalid logical unit Response code 00 02 04 05 08 09 Constellation ES.2 SAS Product Manual, Rev.
... Yes Yes Yes Yes Yes 12.1.2 task management responses Table 5 lists the SAS response codes returned for task management functions supported. 12.0 Interface requirements This section partially describes the interface requirements as implemented on Constellation ES.2 drives. C 45 Table 5: Task ...management response codes Function name Function complete Invalid frame Function not supported Function failed Function succeeded Invalid logical unit Response code 00 02 04 05 08 09 Constellation ES.2 SAS Product Manual, Rev.
Constellation ES.2 SAS Product Manual
Page 54
...ports have two independent ports. The supported link rates are 1.5, 3.0, or 6.0 Gb/s. Each drive port has a unique SAS address. Subject to buffer availability, the Constellation ES.2 drives support: • Concurrent port transfers-The drive supports receiving COMMAND, TASK management transfers on ...both ports at the same time. • Full duplex-The drive supports sending XFER_RDY, DATA and RESPONSE transfers while receiving...
...ports have two independent ports. The supported link rates are 1.5, 3.0, or 6.0 Gb/s. Each drive port has a unique SAS address. Subject to buffer availability, the Constellation ES.2 drives support: • Concurrent port transfers-The drive supports receiving COMMAND, TASK management transfers on ...both ports at the same time. • Full duplex-The drive supports sending XFER_RDY, DATA and RESPONSE transfers while receiving...
Constellation ES.2 SAS Product Manual
Page 55
... (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD bit ETC bit ...
... (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD bit ETC bit ...
Constellation ES.2 SAS Product Manual
Page 56
... Command name Command code Last n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) Self-test Results page (10h) Start-stop Cycle Counter page (0Eh) Temperature ...(10) (same pages as Mode Sense 1Ah) 5Ah Persistent Reserve In 5Eh Persistent Reserve Out 5Fh Prefetch 34h Read (6) 08h Read (10) 28h DPO bit supported FUA bit supported Read (12) A8h Read (16) 88h Read (32) 7Fh/0009h Read Buffer (modes 0, 2, 3, Ah and Bh...
... Command name Command code Last n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) Self-test Results page (10h) Start-stop Cycle Counter page (0Eh) Temperature ...(10) (same pages as Mode Sense 1Ah) 5Ah Persistent Reserve In 5Eh Persistent Reserve Out 5Fh Prefetch 34h Read (6) 08h Read (10) 28h DPO bit supported FUA bit supported Read (12) A8h Read (16) 88h Read (32) 7Fh/0009h Read Buffer (modes 0, 2, 3, Ah and Bh...
Constellation ES.2 SAS Product Manual
Page 57
... Read Capacity (16) Read Defect Data (10) Read Defect Data (12) Read Long Read Long (16) Reassign Blocks Receive Diagnostic Results Supported Diagnostics pages (00h) Translate page (40h) Release Release (10) Report LUNs Request Sense Actual Retry Count bytes Extended Sense Field Pointer bytes ... Rezero Unit Search Data Equal Search Data High Search Data Low Security Protocol In Security Protocol Out Seek (6) Seek (10) Send Diagnostics Supported Diagnostics pages (00h) Translate page (40h) Set Limits Start Unit/Stop Unit (spindle ceases rotating) Synchronize Cache Synchronize Cache (16) ...
... Read Capacity (16) Read Defect Data (10) Read Defect Data (12) Read Long Read Long (16) Reassign Blocks Receive Diagnostic Results Supported Diagnostics pages (00h) Translate page (40h) Release Release (10) Report LUNs Request Sense Actual Retry Count bytes Extended Sense Field Pointer bytes ... Rezero Unit Search Data Equal Search Data High Search Data Low Security Protocol In Security Protocol Out Seek (6) Seek (10) Send Diagnostics Supported Diagnostics pages (00h) Translate page (40h) Set Limits Start Unit/Stop Unit (spindle ceases rotating) Synchronize Cache Synchronize Cache (16) ...
Constellation ES.2 SAS Product Manual
Page 58
...Write (32) Write and Verify (10) DPO bit Write and Verify (12) Write and Verify (16) Write and Verify (32) Write Buffer (modes 0, 2, supported) Write Buffer Firmware Download option (modes 5, 7, Ah and Bh) [3] Firmware Download option (modes 4, 5, 7) Write Long (10) Write Long (16) Write Same... only) Y (SED drives only) Y Y Y N N Y N N N N [1] Constellation ES.2 drives can result in firmware corruption. Command is supported. A = Support is available on special request. 50 Constellation ES.2 SAS Product Manual, Rev. N = No. Power loss during flash programming can format to 512, 520 or...
...Write (32) Write and Verify (10) DPO bit Write and Verify (12) Write and Verify (16) Write and Verify (32) Write Buffer (modes 0, 2, supported) Write Buffer Firmware Download option (modes 5, 7, Ah and Bh) [3] Firmware Download option (modes 4, 5, 7) Write Long (10) Write Long (16) Write Same... only) Y (SED drives only) Y Y Y N N Y N N N N [1] Constellation ES.2 drives can result in firmware corruption. Command is supported. A = Support is available on special request. 50 Constellation ES.2 SAS Product Manual, Rev. N = No. Power loss during flash programming can format to 512, 520 or...
Constellation ES.2 SAS Product Manual
Page 59
... values in a Mode Select command to the initiator. It is applied to change the current values (or the saved values) with actual year). ** SCSI Revision support. C 51 PP 10 = Inquiry data for an Inquiry command received on Port A. 30 = Inquiry data for the drive to report its operating parameters to set...
... values in a Mode Select command to the initiator. It is applied to change the current values (or the saved values) with actual year). ** SCSI Revision support. C 51 PP 10 = Inquiry data for an Inquiry command received on Port A. 30 = Inquiry data for the drive to report its operating parameters to set...
Constellation ES.2 SAS Product Manual
Page 62
...Extended Sense bytes 15, 16, and 17 N Adaptive caching Y SMP = 1 in the support column indicates the feature or condition is not supported. Table 9: Miscellaneous features Supported Feature or condition N Automatic contingent allegiance N Asynchronous event notification N Synchronized (locked) spindle ... Y Segmented caching N Zero latency read Y Queue tagging (up to save RPL and rotational offset bytes Table 10: Miscellaneous status Supported Y Y Y Y Y Y Y Y N N Status Good Check condition Condition met/good Busy Intermediate/good Intermediate/condition met/good...
...Extended Sense bytes 15, 16, and 17 N Adaptive caching Y SMP = 1 in the support column indicates the feature or condition is not supported. Table 9: Miscellaneous features Supported Feature or condition N Automatic contingent allegiance N Asynchronous event notification N Synchronized (locked) spindle ... Y Segmented caching N Zero latency read Y Queue tagging (up to save RPL and rotational offset bytes Table 10: Miscellaneous status Supported Y Y Y Y Y Y Y Y N N Status Good Check condition Condition met/good Busy Intermediate/good Intermediate/condition met/good...
Constellation ES.2 SAS Product Manual
Page 66
... of the SAS device and a description of this publication when production parts are available from major connector manufacturers. C The SAS device connector is designed to support hot plugging NC -
... of the SAS device and a description of this publication when production parts are available from major connector manufacturers. C The SAS device connector is designed to support hot plugging NC -