User Manual
Page 8
coins, knives, pins, etc. Never plug the power cord into the appliance when the drum is not grounded adequately or not in a dangerous situation. Cautions CAUTION • Do not allow children or pets to ...
coins, knives, pins, etc. Never plug the power cord into the appliance when the drum is not grounded adequately or not in a dangerous situation. Cautions CAUTION • Do not allow children or pets to ...
User Manual
Page 10
...:13 WARNING • Make sure to exhaust the dryer outdoors to prevent a child from water and weather. Key installation requirements • A grounded electrical outlet. • A power cord for electric dryers (except in . (460 mm) above the floor for future reference. Installation requirements Installation requirements Read through the following parts while the appliance...
...:13 WARNING • Make sure to exhaust the dryer outdoors to prevent a child from water and weather. Key installation requirements • A grounded electrical outlet. • A power cord for electric dryers (except in . (460 mm) above the floor for future reference. Installation requirements Installation requirements Read through the following parts while the appliance...
User Manual
Page 18
...to a permanently grounded metal wiring system, or an equipment grounding conductor must be plugged into a 30-ampere receptacle. • The power cord is not provided with a 15-ampere fuse or circuit breaker is required. An individual branch (or separate) circuit serving only your dryer... service. if it doesn't fit the outlet, have a proper outlet installed by a qualified electrician. • If a power cord is not used , the cord should be plugged into an appropriate outlet that is properly installed and grounded in accordance with all grounding instructions in the "Grounding...
...to a permanently grounded metal wiring system, or an equipment grounding conductor must be plugged into a 30-ampere receptacle. • The power cord is not provided with a 15-ampere fuse or circuit breaker is required. An individual branch (or separate) circuit serving only your dryer... service. if it doesn't fit the outlet, have a proper outlet installed by a qualified electrician. • If a power cord is not used , the cord should be plugged into an appropriate outlet that is properly installed and grounded in accordance with all grounding instructions in the "Grounding...
User Manual
Page 19
...ampere fuse or circuit breaker on both sides of Electric Shock When local codes allow, you may convert a dryer to 120 / 208 volts. The power cord should be supported at a minimum of 120 / 240 volts, 30-amperes with three No. 10 copper wire conductors terminated with closed loop terminals, open...-end spade lugs with turned up ends, or with the power cord attached. NOTE All Canadian models are shipped with tinned leads. • Do not reuse a power supply cord from an old dryer. listed and rated at the dryer cabinet by a suitable UL-listed ...
...ampere fuse or circuit breaker on both sides of Electric Shock When local codes allow, you may convert a dryer to 120 / 208 volts. The power cord should be supported at a minimum of 120 / 240 volts, 30-amperes with three No. 10 copper wire conductors terminated with closed loop terminals, open...-end spade lugs with turned up ends, or with the power cord attached. NOTE All Canadian models are shipped with tinned leads. • Do not reuse a power supply cord from an old dryer. listed and rated at the dryer cabinet by a suitable UL-listed ...
User Manual
Page 25
... the cold water tap. The dryer frame is required for a 3-wire system connection. A 4-wire system connection is grounded to the cold water tap. 2. Insert the power cord with a UL-listed strain relief through neutral. Then, connect the female end of the water hose to the cold water tap, unscrew and remove the...
... the cold water tap. The dryer frame is required for a 3-wire system connection. A 4-wire system connection is grounded to the cold water tap. 2. Insert the power cord with a UL-listed strain relief through neutral. Then, connect the female end of the water hose to the cold water tap, unscrew and remove the...
User Manual
Page 29
Then, plug the power cord into an electrical outlet and grounded properly. • The exhaust ductwork is connected, and the joints are taped.... is sitting firmly on . STEP 7 Final check When installation is complete, confirm that: • The dryer is plugged into a power source and check the dryer's installation and operation using the final checklist in the gas line. CAUTION The burner may not ignite initially due... correctly. Allowing your dryer off properly. Installation Untitled-16 29 English 29 2020-07-14 3:36:17 STEP 6 Power on a heat setting will purge the line.
Then, plug the power cord into an electrical outlet and grounded properly. • The exhaust ductwork is connected, and the joints are taped.... is sitting firmly on . STEP 7 Final check When installation is complete, confirm that: • The dryer is plugged into a power source and check the dryer's installation and operation using the final checklist in the gas line. CAUTION The burner may not ignite initially due... correctly. Allowing your dryer off properly. Installation Untitled-16 29 English 29 2020-07-14 3:36:17 STEP 6 Power on a heat setting will purge the line.
User Manual
Page 32
... door on a regular basis. WARNING • To prevent fire, do not use plastic, thin-foil, or non-metal flexible ducts of the dryer. 3. Unplug the power cord of any kind. • Do not use a poor exhaust system because it slows down the dryer's performance. • Do not use excessively long ducts that...
... door on a regular basis. WARNING • To prevent fire, do not use plastic, thin-foil, or non-metal flexible ducts of the dryer. 3. Unplug the power cord of any kind. • Do not use a poor exhaust system because it slows down the dryer's performance. • Do not use excessively long ducts that...
User Manual
Page 50
... Untitled-16 50 2020-07-14 3:36:22 Problem Does not run. Action • Make sure the door is latched shut. • Make sure the power cord is plugged into the cool-down phase of the cycle to Start) again if the door is on, the dryer performs an air dry process...
... Untitled-16 50 2020-07-14 3:36:22 Problem Does not run. Action • Make sure the door is latched shut. • Make sure the power cord is plugged into the cool-down phase of the cycle to Start) again if the door is on, the dryer performs an air dry process...
User Manual
Page 55
Cut off the power cord so that animals and small children cannot get trapped inside the appliance. Specification Untitled-16 55 English 55 2020-07-14 3:36:26 Remove the door so that the appliance cannot be connected to a power source. Iron dry or steam temperatures High Medium Low Warning symbols for laundering Do...
Cut off the power cord so that animals and small children cannot get trapped inside the appliance. Specification Untitled-16 55 English 55 2020-07-14 3:36:26 Remove the door so that the appliance cannot be connected to a power source. Iron dry or steam temperatures High Medium Low Warning symbols for laundering Do...