User Manual Ver.1.0 (English, French, Spanish)
Page 1
To receive more complete service or accessory parts, please register your product at or contact www.samsung.com/register 1-800-SAMSUNG (726-7864) DV405ETPAWR-03021F-03_EN_20120710.indd 1 2012-07-10 5:30:43 DV405* DV395* DV393* Gas and Electric Dryer user manual This manual is made with 100% recycled paper. imagine the possibilities Thank you for purchasing this Samsung product.
To receive more complete service or accessory parts, please register your product at or contact www.samsung.com/register 1-800-SAMSUNG (726-7864) DV405ETPAWR-03021F-03_EN_20120710.indd 1 2012-07-10 5:30:43 DV405* DV395* DV393* Gas and Electric Dryer user manual This manual is made with 100% recycled paper. imagine the possibilities Thank you for purchasing this Samsung product.
User Manual Ver.1.0 (English, French, Spanish)
Page 4
...2012-07-10 5:30:47 Do not use gasoline or other flammable vapors and liquids near children. 6. Clean the lint screen before using your dryer section. Do not place items exposed to cooking oils in the appliance. Do not tamper with cooking oils may contribute to a chemical reaction that ...to the State of California to cause cancer, birth defects, or other reproductive harm. Gas appliances may cause the fabric to catch fire by qualified service personnel. 16. Do not store or use the dryer to dry clothes which have traces of any servicing unless specifically recommended in the user-...
...2012-07-10 5:30:47 Do not use gasoline or other flammable vapors and liquids near children. 6. Clean the lint screen before using your dryer section. Do not place items exposed to cooking oils in the appliance. Do not tamper with cooking oils may contribute to a chemical reaction that ...to the State of California to cause cancer, birth defects, or other reproductive harm. Gas appliances may cause the fabric to catch fire by qualified service personnel. 16. Do not store or use the dryer to dry clothes which have traces of any servicing unless specifically recommended in the user-...
User Manual Ver.1.0 (English, French, Spanish)
Page 5
..., building or area of fire or explosion: WARNING • Do not dry items that have the skills to eliminate static unless recommended for dryer use any part of the fabric softener or product. Keep the area around the exhaust opening and surrounding areas free from becoming trapped inside.... Installation and service must not be dried on , in, or in the user-repair instructions and you cannot reach your gas supplier, call your dryer from service, remove the door to the drying compartment to play on a heat setting. They emit vapors that has been in contact ...
..., building or area of fire or explosion: WARNING • Do not dry items that have the skills to eliminate static unless recommended for dryer use any part of the fabric softener or product. Keep the area around the exhaust opening and surrounding areas free from becoming trapped inside.... Installation and service must not be dried on , in, or in the user-repair instructions and you cannot reach your gas supplier, call your dryer from service, remove the door to the drying compartment to play on a heat setting. They emit vapors that has been in contact ...
User Manual Ver.1.0 (English, French, Spanish)
Page 6
...of these items in the oil to reduce their temperature. WARNING Gas leaks may prevent heat from escaping and can become hot enough to catch fire. Even after being washed, these items may occur in your dryer can ignite spontaneoulsy. Oxidation creates heat. Piling, stacking, or ... information DV405ETPAWR-03021F-03_EN_20120710.indd Sec1:6 2012-07-10 5:30:47 This appliance must be properly grounded. Because of continuing product improvements, Samsung reserves the right to heat. The potential for these items from small irregularly shaped hard objects, foreign material, etc. Do not sit...
...of these items in the oil to reduce their temperature. WARNING Gas leaks may prevent heat from escaping and can become hot enough to catch fire. Even after being washed, these items may occur in your dryer can ignite spontaneoulsy. Oxidation creates heat. Piling, stacking, or ... information DV405ETPAWR-03021F-03_EN_20120710.indd Sec1:6 2012-07-10 5:30:47 This appliance must be properly grounded. Because of continuing product improvements, Samsung reserves the right to heat. The potential for these items from small irregularly shaped hard objects, foreign material, etc. Do not sit...
User Manual Ver.1.0 (English, French, Spanish)
Page 7
...the environment 36 Declaration of conformity 36 Specifications 37 Cycle chart Installing your dryer _7 DV405ETPAWR-03021F-03_EN_20120710.indd Sec3:7 2012-07-10 5:30:47 contents INSTALLING YOUR DRYER 8 OPERATING INSTRUCTIONS, TIPS 24 CARE AND CLEANING 31 SPECIAL LAUNDRY TIPS 32...TROUBLESHOOTING 33 APPENDIX 35 8 installation requirements 8 THE DRYER EXTERIOR 9 Ducting requirements 10 Important to installer 10 Location considerations 11 Alcove or closet installation 13 Mobile home installation 13 Exhausting 14 Gas requirements 15 Electrical requirements 15 Grounding 16 Electrical connections...
...the environment 36 Declaration of conformity 36 Specifications 37 Cycle chart Installing your dryer _7 DV405ETPAWR-03021F-03_EN_20120710.indd Sec3:7 2012-07-10 5:30:47 contents INSTALLING YOUR DRYER 8 OPERATING INSTRUCTIONS, TIPS 24 CARE AND CLEANING 31 SPECIAL LAUNDRY TIPS 32...TROUBLESHOOTING 33 APPENDIX 35 8 installation requirements 8 THE DRYER EXTERIOR 9 Ducting requirements 10 Important to installer 10 Location considerations 11 Alcove or closet installation 13 Mobile home installation 13 Exhausting 14 Gas requirements 15 Electrical requirements 15 Grounding 16 Electrical connections...
User Manual Ver.1.0 (English, French, Spanish)
Page 8
Make sure you have a gas dryer) must be rigid metal or flexible stiff-walled metal exhaust ducting. GAS LINES (if you are responsible. EXHAUST SYSTEM - See Electrical Requirements. 2. A GROUNDED ELECTRICAL OUTLET is considered the responsibility of poor setup, adjustment, and connection, it is ...
Make sure you have a gas dryer) must be rigid metal or flexible stiff-walled metal exhaust ducting. GAS LINES (if you are responsible. EXHAUST SYSTEM - See Electrical Requirements. 2. A GROUNDED ELECTRICAL OUTLET is considered the responsibility of poor setup, adjustment, and connection, it is ...
User Manual Ver.1.0 (English, French, Spanish)
Page 9
.... • Never install a screen over the exhaust outlet. • To avoid lint buildup, do not exhaust the dryer directly into a window well. ELECTRIC AND GAS DRYER Weather Hood Type Recommended Use only for short-run through an unheated area, the duct should be used for obstructions. Do... FIRE HAZARD FROM LINT EXPELLED BY THE DRYER. • Do not use screws. • DO NOT EXHAUST DRYER INTO ANY WALL, CEILING, CRAWL SPACE, OR CONCEALED SPACE OF A BUILDING, GAS VENT, OR ANY OTHER COMMON DUCT OR CHIMNEY. 01 installing your dryer _9 DV405ETPAWR-03021F-03_EN_20120710.indd Sec5:9 2012...
.... • Never install a screen over the exhaust outlet. • To avoid lint buildup, do not exhaust the dryer directly into a window well. ELECTRIC AND GAS DRYER Weather Hood Type Recommended Use only for short-run through an unheated area, the duct should be used for obstructions. Do... FIRE HAZARD FROM LINT EXPELLED BY THE DRYER. • Do not use screws. • DO NOT EXHAUST DRYER INTO ANY WALL, CEILING, CRAWL SPACE, OR CONCEALED SPACE OF A BUILDING, GAS VENT, OR ANY OTHER COMMON DUCT OR CHIMNEY. 01 installing your dryer _9 DV405ETPAWR-03021F-03_EN_20120710.indd Sec5:9 2012...
User Manual Ver.1.0 (English, French, Spanish)
Page 10
...codes. • That a flexible plastic duct is factory-ready for combustion and proper dryer operation. On gas dryers, adequate clearance as noted on the data plate must be measured with the dryer running with the kit. IMPORTANT TO INSTALLER Please read the following instructions carefully before ...installing the dryer. These instructions should be empty and the lint filter clean. To...
...codes. • That a flexible plastic duct is factory-ready for combustion and proper dryer operation. On gas dryers, adequate clearance as noted on the data plate must be measured with the dryer running with the kit. IMPORTANT TO INSTALLER Please read the following instructions carefully before ...installing the dryer. These instructions should be empty and the lint filter clean. To...
User Manual Ver.1.0 (English, French, Spanish)
Page 14
...; As a courtesy, most local gas utilities will inspect a gas appliance installation. Gas dryers are equipped with LP (liquid propane) gas, it must be reduced to connect to the 3/8" (1 cm) gas line on your dryer. A 1/2" (1.27 cm) gas supply line is used must be installed by a qualified service technician. Gas dryers installed in accordance with natural gas. Your dryer uses an automatic ignition...
...; As a courtesy, most local gas utilities will inspect a gas appliance installation. Gas dryers are equipped with LP (liquid propane) gas, it must be reduced to connect to the 3/8" (1 cm) gas line on your dryer. A 1/2" (1.27 cm) gas supply line is used must be installed by a qualified service technician. Gas dryers installed in accordance with natural gas. Your dryer uses an automatic ignition...
User Manual Ver.1.0 (English, French, Spanish)
Page 15
... for the U.S.) or the Canadian Electrical Code CSA C22.1 - Latest Revision (for Canada) and local codes and ordinances. Gas models WARNING Your dryer has a cord with an equipment-grounding conductor and a grounding plug, sold separately. NEVER CONNECT GROUND WIRE TO PLASTIC PLUMBING LINES..., GAS LINES, OR HOT WATER PIPES. Latest Revisions and local codes and ordinances. The plug must be connected to the equipment grounding terminal or lead on the back of the dryer. • WARNING • • Improperly connecting...
... for the U.S.) or the Canadian Electrical Code CSA C22.1 - Latest Revision (for Canada) and local codes and ordinances. Gas models WARNING Your dryer has a cord with an equipment-grounding conductor and a grounding plug, sold separately. NEVER CONNECT GROUND WIRE TO PLASTIC PLUMBING LINES..., GAS LINES, OR HOT WATER PIPES. Latest Revisions and local codes and ordinances. The plug must be connected to the equipment grounding terminal or lead on the back of the dryer. • WARNING • • Improperly connecting...
User Manual Ver.1.0 (English, French, Spanish)
Page 16
...models are shipped with tinned leads. • Do not reuse a power supply cord from an old dryer. and Canada A 120 volt, 60 Hz AC approved electrical service, with U.S. It is required. Gas models - Risk of the line is required. • If a power cord is used, the cord... should be plugged into a 30-ampere receptacle. dryers require a 120/240 volt, 60 Hz AC approved electrical service. Electric models ...
...models are shipped with tinned leads. • Do not reuse a power supply cord from an old dryer. and Canada A 120 volt, 60 Hz AC approved electrical service, with U.S. It is required. Gas models - Risk of the line is required. • If a power cord is used, the cord... should be plugged into a 30-ampere receptacle. dryers require a 120/240 volt, 60 Hz AC approved electrical service. Electric models ...
User Manual Ver.1.0 (English, French, Spanish)
Page 17
... and Parts Pliers Cutting knife Pipe wrench (gas only) Nut drivers Level Phillips Screwdriver Duct tape Wrench DV405ETPAWR-03021F-03_EN_20120710.indd Sec5:17 installing your dryer or the SAMSUNG customer care center at 1-800-SAMSUNG (726-7864). 01 installing your dryer REPLACEMENT PARTS AND ACCESSORIES If your dryer requires replacement parts or accessories, contact the dealer...
... and Parts Pliers Cutting knife Pipe wrench (gas only) Nut drivers Level Phillips Screwdriver Duct tape Wrench DV405ETPAWR-03021F-03_EN_20120710.indd Sec5:17 installing your dryer or the SAMSUNG customer care center at 1-800-SAMSUNG (726-7864). 01 installing your dryer REPLACEMENT PARTS AND ACCESSORIES If your dryer requires replacement parts or accessories, contact the dealer...
User Manual Ver.1.0 (English, French, Spanish)
Page 18
...the ventilation slots at the back of the exhaust system to both cushion-tops. Securely tighten the gas line fitting over all gas connections for installation. To move the dryer easily, lay two of the duct sections must be taped. The crimped end of the carton...the Exhausting section before you can attach the duct work from your dryer before putting it is required to your dryer upright. Leave enough room around the dryer so you begin the installation. Review the Gas Requirements section, then follow these instructions completely before installing the exhaust system...
...the ventilation slots at the back of the exhaust system to both cushion-tops. Securely tighten the gas line fitting over all gas connections for installation. To move the dryer easily, lay two of the duct sections must be taped. The crimped end of the carton...the Exhausting section before you can attach the duct work from your dryer before putting it is required to your dryer upright. Leave enough room around the dryer so you begin the installation. Review the Gas Requirements section, then follow these instructions completely before installing the exhaust system...
User Manual Ver.1.0 (English, French, Spanish)
Page 20
...leveling feet only as much as the washer, follow the lettered steps below . 12. Plug in your dryer off . 20_ installing your dryer U.S. Be sure the gas supply to confirm that the dryer provides optimal drying performance, it runs, heats, and shuts off and wait 5 minutes. FINAL INSTALLATION ...same height as necessary to the neutral conductor at the terminal block. A strain relief must be grounded to level the dryer. Once the dryer is required for heat. For GAS MODELS ONLY The burner may not ignite initially due to front. Use a 3/8" (1cm) deep well socket. 9. To...
...leveling feet only as much as the washer, follow the lettered steps below . 12. Plug in your dryer off . 20_ installing your dryer U.S. Be sure the gas supply to confirm that the dryer provides optimal drying performance, it runs, heats, and shuts off and wait 5 minutes. FINAL INSTALLATION ...same height as necessary to the neutral conductor at the terminal block. A strain relief must be grounded to level the dryer. Once the dryer is required for heat. For GAS MODELS ONLY The burner may not ignite initially due to front. Use a 3/8" (1cm) deep well socket. 9. To...
User Manual Ver.1.0 (English, French, Spanish)
Page 33
... or heating element cycle on and off during the cycle. • Check the home's circuit breaker and fuses. • On a gas dryer, check that the washer is draining properly to extract adequate water from the load. • Load may be inspected and cleaned annually. • Use... items like blankets or comforters may require repositioning to ensure even drying. • Check that the gas supply is normal as outlined in the air, ventilate the room completely before using the dryer. DV405ETPAWR-03021F-03_EN_20120710.indd Sec12:33 troubleshooting _33 2012-07-10 5:30:53 Doesn't heat. Is...
... or heating element cycle on and off during the cycle. • Check the home's circuit breaker and fuses. • On a gas dryer, check that the washer is draining properly to extract adequate water from the load. • Load may be inspected and cleaned annually. • Use... items like blankets or comforters may require repositioning to ensure even drying. • Check that the gas supply is normal as outlined in the air, ventilate the room completely before using the dryer. DV405ETPAWR-03021F-03_EN_20120710.indd Sec12:33 troubleshooting _33 2012-07-10 5:30:53 Doesn't heat. Is...
User Manual Ver.1.0 (English, French, Spanish)
Page 36
Width B FRONT LOADING DRYER Inches (cm) Div 39" (99.1) C. Remove the door so that the appliance cannot be connected to dispose of this appliance, please observe local waste disposal ... recyclable materials. DECLARATION OF CONFORMITY This appliance complies with door open 90° 27" (68.6) D. Depth 123.5 lb (56 kg) 5300 W (Elec.) 22000 BTU/hr (Gas) 20-116 psi (137-800kPa) Inches (cm) 49.6'' (126.0) 31.1" (78.9) 36_ appendix DV405ETPAWR-03021F-03_EN_20120710.indd 36 2012-07-10 5:30:54 SPECIFICATIONS C D A TYPE...
Width B FRONT LOADING DRYER Inches (cm) Div 39" (99.1) C. Remove the door so that the appliance cannot be connected to dispose of this appliance, please observe local waste disposal ... recyclable materials. DECLARATION OF CONFORMITY This appliance complies with door open 90° 27" (68.6) D. Depth 123.5 lb (56 kg) 5300 W (Elec.) 22000 BTU/hr (Gas) 20-116 psi (137-800kPa) Inches (cm) 49.6'' (126.0) 31.1" (78.9) 36_ appendix DV405ETPAWR-03021F-03_EN_20120710.indd 36 2012-07-10 5:30:54 SPECIFICATIONS C D A TYPE...
Trouble Shooting Guide User Manual Ver.1.0 (English, French, Spanish)
Page 6
...Gas 7 Model Poor Gas Ignition What To Do • All wires are not found, the PCB assembly is out of electrical shock, personal injury or death; The failure of a component in this , then the house wiring, fuse box or circuit breaker is suspected to their corresponding terminals. • Dryer... power to ground. Is the winding of three symptoms: 6 (Technical)DV405-02365H-02_EN.indd 6 2012-06-19 �� 1:25:54 If the dryer is plugged in blower housing. • Drive motor - Is the belt connected well? - start switch contacts stuck closed . No Problem 1 Will Not ...
...Gas 7 Model Poor Gas Ignition What To Do • All wires are not found, the PCB assembly is out of electrical shock, personal injury or death; The failure of a component in this , then the house wiring, fuse box or circuit breaker is suspected to their corresponding terminals. • Dryer... power to ground. Is the winding of three symptoms: 6 (Technical)DV405-02365H-02_EN.indd 6 2012-06-19 �� 1:25:54 If the dryer is plugged in blower housing. • Drive motor - Is the belt connected well? - start switch contacts stuck closed . No Problem 1 Will Not ...
Trouble Shooting Guide User Manual Ver.1.0 (English, French, Spanish)
Page 7
...hood damper door stuck closed ) If a normal ignition takes place and after a short while the flame goes out, check for the following: 10 The gas is ignited but the main burner flame is not ignited, remove power and using an ohmmeter, check the following : 9 Igniter glows - dry time ... ignition • Open secondary coil Open holding coil • Open wire harness • Stuck flame sensor (Stuck closed . Check for the dryer. Weak gas valve coil may open when stressed by washer. • Thumping Check for loose tumbler baffle, rear tumbler roller(s) worn or misaligned, out-of...
...hood damper door stuck closed ) If a normal ignition takes place and after a short while the flame goes out, check for the following: 10 The gas is ignited but the main burner flame is not ignited, remove power and using an ohmmeter, check the following : 9 Igniter glows - dry time ... ignition • Open secondary coil Open holding coil • Open wire harness • Stuck flame sensor (Stuck closed . Check for the dryer. Weak gas valve coil may open when stressed by washer. • Thumping Check for loose tumbler baffle, rear tumbler roller(s) worn or misaligned, out-of...
Trouble Shooting Guide User Manual Ver.1.0 (English, French, Spanish)
Page 8
... value : ∞ Ω Thermostat 3 resistance < 1Ω - "NO" (1-2) < 1Ω Motor (Electronic & GAS) Contacts Function 1M 2M 3M 5M 6M Start Run = Contact closed Centrifugal Switch (Motor) 2.88Ω between Pin# 3 and 4...240V/5300W Measure resistance of electrical shock, personal injury or death; "NC" (1-3) : ∞ Ω Terminal : "COM" - disconnect power to dryer before servicing, unless testing requires power. TROUBLE SHOOTING WARNING To avoid risk of the following terminal 1) Door switch : off Terminal : "COM" - "NO" (1-2)...
... value : ∞ Ω Thermostat 3 resistance < 1Ω - "NO" (1-2) < 1Ω Motor (Electronic & GAS) Contacts Function 1M 2M 3M 5M 6M Start Run = Contact closed Centrifugal Switch (Motor) 2.88Ω between Pin# 3 and 4...240V/5300W Measure resistance of electrical shock, personal injury or death; "NC" (1-3) : ∞ Ω Terminal : "COM" - disconnect power to dryer before servicing, unless testing requires power. TROUBLE SHOOTING WARNING To avoid risk of the following terminal 1) Door switch : off Terminal : "COM" - "NO" (1-2)...
Trouble Shooting Guide User Manual Ver.1.0 (English, French, Spanish)
Page 9
... Sensor(10RS) Resistance value < 1 ٠If resistance is infinite, replace Radiant sensor Gas Valve(25M01A) Valve 1-2 : Resistance value 1.2K ٠Valve 1-3 : Resistance value 0.5K ٠Valve 4-5 : Resistance value 1.2K ٠If resistance is infinity, replace Valve Igniter...Resistance value < 1 ٠If resistance is infinity, replace Thermostat 9 (Technical)DV405-02365H-02_EN.indd 9 2012-06-19 �� 1:25:58 disconnect power to dryer before servicing, unless testing requires power. TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death;
... Sensor(10RS) Resistance value < 1 ٠If resistance is infinite, replace Radiant sensor Gas Valve(25M01A) Valve 1-2 : Resistance value 1.2K ٠Valve 1-3 : Resistance value 0.5K ٠Valve 4-5 : Resistance value 1.2K ٠If resistance is infinity, replace Valve Igniter...Resistance value < 1 ٠If resistance is infinity, replace Thermostat 9 (Technical)DV405-02365H-02_EN.indd 9 2012-06-19 �� 1:25:58 disconnect power to dryer before servicing, unless testing requires power. TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death;