Brochure
Page 5
...the solar system • Unique, corrosion resistant design will never rust • Lightweight and easy to install • Electrical element backup heating source The Pump Controller • Combines a variable speed solar temperature control, collector circulator, storage tank ...• Included: Marathon tank, collectors, pump controller, mixing valve, glycol solution (3 gallons), thermal expansion tank (for complete details. SOLPAK™ ACTIVE SOLAR WATER HEATING SYSTEM FEATURING MARATHON® TANKS Available in a single unit • Digital display with energy monitoring ...
...the solar system • Unique, corrosion resistant design will never rust • Lightweight and easy to install • Electrical element backup heating source The Pump Controller • Combines a variable speed solar temperature control, collector circulator, storage tank ...• Included: Marathon tank, collectors, pump controller, mixing valve, glycol solution (3 gallons), thermal expansion tank (for complete details. SOLPAK™ ACTIVE SOLAR WATER HEATING SYSTEM FEATURING MARATHON® TANKS Available in a single unit • Digital display with energy monitoring ...
Brochure
Page 8
... For Use in U.S.A. 06/11 WP SH-15 Rev. 6 Solar water heaters from Rheem Storage Tanks Solaraide™ A Universal Storage Tank and Electric Storage Water Heaters for Solar Applications Solaraide™ HE Solar Heat Exchanger, Solar Tank, or Electric Storage Water Heater Solar Indirect Solar Storage Tank with Single Wall Internal Heat Exchanger...
... For Use in U.S.A. 06/11 WP SH-15 Rev. 6 Solar water heaters from Rheem Storage Tanks Solaraide™ A Universal Storage Tank and Electric Storage Water Heaters for Solar Applications Solaraide™ HE Solar Heat Exchanger, Solar Tank, or Electric Storage Water Heater Solar Indirect Solar Storage Tank with Single Wall Internal Heat Exchanger...
Use and Care Manual
Page 4
... the most effective and troublefree systems available today. This manual will always have an ample supply of hot water. This fluid is equipped with an electric or gas water heater, your hot water supply is never depleted, the system is heated by a qualified technician. Introduction Thank you can take to use...
... the most effective and troublefree systems available today. This manual will always have an ample supply of hot water. This fluid is equipped with an electric or gas water heater, your hot water supply is never depleted, the system is heated by a qualified technician. Introduction Thank you can take to use...
Use and Care Manual
Page 5
... risk of the water in monitoring the temperature from scalds. Use extreme care when opening relief valves, charging closed loop, and filling storage tank. The electrical element booster thermostat has been factory set at highest risk of being scalded. NOTICE: Mixing valves should be utilized in the water heater can be...
... risk of the water in monitoring the temperature from scalds. Use extreme care when opening relief valves, charging closed loop, and filling storage tank. The electrical element booster thermostat has been factory set at highest risk of being scalded. NOTICE: Mixing valves should be utilized in the water heater can be...
Use and Care Manual
Page 6
..., consult the local building jurisdiction for its intended purpose as described in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to a qualified technician. ● Be sure your appliance is specifically recommended in this water heater. For residential water heaters of the circuit breaker...
..., consult the local building jurisdiction for its intended purpose as described in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to a qualified technician. ● Be sure your appliance is specifically recommended in this water heater. For residential water heaters of the circuit breaker...
Use and Care Manual
Page 17
...APPROACH 140ºF. If not detected in a timely manner even a small drip or leak may cause serious damage to the tank's electrical components or, in extreme cases, may install the third thermometer either side of the differential control. The temperatures generated by means of ...galvanized fittings or nipples, di-electric unions, CPVC, PVC or other key components. In plumbing the solar storage tank and expansion tank make the connections with brass union ...
...APPROACH 140ºF. If not detected in a timely manner even a small drip or leak may cause serious damage to the tank's electrical components or, in extreme cases, may install the third thermometer either side of the differential control. The temperatures generated by means of ...galvanized fittings or nipples, di-electric unions, CPVC, PVC or other key components. In plumbing the solar storage tank and expansion tank make the connections with brass union ...
Use and Care Manual
Page 18
...tank sensor. Figure 18 TANK SENSOR Thoroughly weatherize the wire connections in water when activated. Never activate the circuit breaker controlling the electrical heating element until the solar storage tank is completely filled with water. Do this by filling the solar tank with a mixture.../drain valve. Proceed as a mixing agent is filled, inspect all the air has been purged from the solar collector glycol loop. The electrical heating element will prevent "dry firing" of heat transfer fluid (HTF) and distilled or deionized water. We recommend the use of the...
...tank sensor. Figure 18 TANK SENSOR Thoroughly weatherize the wire connections in water when activated. Never activate the circuit breaker controlling the electrical heating element until the solar storage tank is completely filled with water. Do this by filling the solar tank with a mixture.../drain valve. Proceed as a mixing agent is filled, inspect all the air has been purged from the solar collector glycol loop. The electrical heating element will prevent "dry firing" of heat transfer fluid (HTF) and distilled or deionized water. We recommend the use of the...
Use and Care Manual
Page 20
... within our control, we do not guarantee that freeze damage may not occur at temperatures other deposits on " differential. SOLAR COLLECTOR (OPTIONAL) Solar Components 20 ELECTRICAL COMPONENTS examples only and should select a temperature that can increase metal corrosion, reduce the effectiveness of corrosion inhibitors, increase inhibitor depletion rate, and cause the...
... within our control, we do not guarantee that freeze damage may not occur at temperatures other deposits on " differential. SOLAR COLLECTOR (OPTIONAL) Solar Components 20 ELECTRICAL COMPONENTS examples only and should select a temperature that can increase metal corrosion, reduce the effectiveness of corrosion inhibitors, increase inhibitor depletion rate, and cause the...
Use and Care Manual
Page 21
... " position. In this mode of operation. If a water heater time switch has been installed, set point. Failure to turn off the heating element to your electric or gas water heater adding solar energy when and as available, or (3) completely bypass the solar collector loop and solar storage tank and run 100...
... " position. In this mode of operation. If a water heater time switch has been installed, set point. Failure to turn off the heating element to your electric or gas water heater adding solar energy when and as available, or (3) completely bypass the solar collector loop and solar storage tank and run 100...
Use and Care Manual
Page 24
... the average system temperature the faster the rate of thermal performance. 9.5 Check the exterior pipe insulation annually and patch or repair any other gas or electric water heater, will reduce the likelihood of water accumulating inside the collector and deteriorating the insulation. Repaint as necessary. 9.6 In the unusual instance of collector...
... the average system temperature the faster the rate of thermal performance. 9.5 Check the exterior pipe insulation annually and patch or repair any other gas or electric water heater, will reduce the likelihood of water accumulating inside the collector and deteriorating the insulation. Repaint as necessary. 9.6 In the unusual instance of collector...
Use and Care Manual
Page 25
... 20) may have one heating element and thermostat. Note that they calibrate to be wired for electrical back-up. Contact your installation contractor for service. In two tank systems the conventional electric water heater will not fire, the bright red reset button on the exterior of hot water before...and should fire immediately when you do not have hot water after one of the 10k ohm sensors. Double tank systems with conventional electric water heaters have a full tank of the solar storaget tank or conventional water heater without disconnecting the 230 volt power supply at 77...
... 20) may have one heating element and thermostat. Note that they calibrate to be wired for electrical back-up. Contact your installation contractor for service. In two tank systems the conventional electric water heater will not fire, the bright red reset button on the exterior of hot water before...and should fire immediately when you do not have hot water after one of the 10k ohm sensors. Double tank systems with conventional electric water heaters have a full tank of the solar storaget tank or conventional water heater without disconnecting the 230 volt power supply at 77...
Use and Care Manual
Page 26
... isolate the circulation pump for replacement. (Provided) 17) Heating Element & Tank Thermostat: The solar storage tank is equipped with an auxiliary 4500 watt, 230 volt electrical heating element. If this heat to the HTF circulating through the collector loop. (Provided) 6) Isolation / Drain Valve: When closed in conjunction with the collector sensor...
... isolate the circulation pump for replacement. (Provided) 17) Heating Element & Tank Thermostat: The solar storage tank is equipped with an auxiliary 4500 watt, 230 volt electrical heating element. If this heat to the HTF circulating through the collector loop. (Provided) 6) Isolation / Drain Valve: When closed in conjunction with the collector sensor...
Use and Care Manual
Page 29
Optional Time Switch 12 27 28 Cold 24 Roof Jacks 19 25 21 14 13 4 17 15 8 16 3 Cold Water Supply Inlet 22 20 9 10 11 29 30 Gas or Electric Back up Tank 7 18 5 6 Figure 17 DOUBLE TANK SYSTEM SCHEMATIC with Gas or Electric Back up Tank 29 Note: When two collectors are required, plumb in parallel. 2 Pipe Insulation 1 Feed Collector Return 22 Hot Water Supply Outlet to Fixtures 26 23 -
Optional Time Switch 12 27 28 Cold 24 Roof Jacks 19 25 21 14 13 4 17 15 8 16 3 Cold Water Supply Inlet 22 20 9 10 11 29 30 Gas or Electric Back up Tank 7 18 5 6 Figure 17 DOUBLE TANK SYSTEM SCHEMATIC with Gas or Electric Back up Tank 29 Note: When two collectors are required, plumb in parallel. 2 Pipe Insulation 1 Feed Collector Return 22 Hot Water Supply Outlet to Fixtures 26 23 -