PPCX2 Manual 1
Page 1
ACTIVE CROSSOVERS INSTRUCTION MANUAL 2-way stereo plus subwoofer OFF +10 LOW GAIN CHANNEL 1 OFF ON 880 390 1.7K 4.1K 30HZ LOW CUT 250 6K XOVER FREQ OFF +10 HIGH GAIN PHASE SUB WOOFER 120 OFF ON 70 170 230 OFF +10 SUB GAIN 30HZ LOW CUT 50 250 XOVER FREQ OFF +10 LOW GAIN CHANNEL 2 OFF ON 880 390 1.7K 4.1K 30HZ LOW CUT 250 6K XOVER FREQ OFF +10 HIGH GAIN PHASE 2-WAY STEREO CROSSOVER PLUS SUBWOOFER ON OFF English
ACTIVE CROSSOVERS INSTRUCTION MANUAL 2-way stereo plus subwoofer OFF +10 LOW GAIN CHANNEL 1 OFF ON 880 390 1.7K 4.1K 30HZ LOW CUT 250 6K XOVER FREQ OFF +10 HIGH GAIN PHASE SUB WOOFER 120 OFF ON 70 170 230 OFF +10 SUB GAIN 30HZ LOW CUT 50 250 XOVER FREQ OFF +10 LOW GAIN CHANNEL 2 OFF ON 880 390 1.7K 4.1K 30HZ LOW CUT 250 6K XOVER FREQ OFF +10 HIGH GAIN PHASE 2-WAY STEREO CROSSOVER PLUS SUBWOOFER ON OFF English
PPCX2 Manual 1
Page 2
...sources such as recommended by items placed upon or against them, paying particular attention to cords and plugs, convenience receptacles and the point where they are not likely to qualified personnel. Retain Instructions: The safety and operating instructions should be taken so that may impede...rain or moisture. Read the manual. in the accompanying literature. Power-Cord Protection: Power supply cords should be situated away from the appliance. This symbol, wherever it appear, alerts you to important operating and maintenance instructions in installation, such as maked on or ...
...sources such as recommended by items placed upon or against them, paying particular attention to cords and plugs, convenience receptacles and the point where they are not likely to qualified personnel. Retain Instructions: The safety and operating instructions should be taken so that may impede...rain or moisture. Read the manual. in the accompanying literature. Power-Cord Protection: Power supply cords should be situated away from the appliance. This symbol, wherever it appear, alerts you to important operating and maintenance instructions in installation, such as maked on or ...
PPCX2 Manual 1
Page 3
... liquid has been spilled into the enclosure through openings. TYPICAL SET-UP HIGH AMP LOW AMP SUB AMP AC INPUT 95-120V /210-240V 60-50Hz Rated Power Consumption 6W FUSE: 210-240V: T100mAL 250VAC 95-120V: 200mA 250VAC REPLACE FUSE WITH CORRECT TYPE ONLY HIGH OUT2 CHANNEL 2 SUB LOW OUT2 INPUT2 (UNBALANCED) INPUT2 (BALANCED) WOOFER HIGH OUT1 CHANNEL 1 LOW OUT1 INPUT1 (UNBALANCED) INPUT1 (BALANCED) Non-use Periods: The power cord of time.
... liquid has been spilled into the enclosure through openings. TYPICAL SET-UP HIGH AMP LOW AMP SUB AMP AC INPUT 95-120V /210-240V 60-50Hz Rated Power Consumption 6W FUSE: 210-240V: T100mAL 250VAC 95-120V: 200mA 250VAC REPLACE FUSE WITH CORRECT TYPE ONLY HIGH OUT2 CHANNEL 2 SUB LOW OUT2 INPUT2 (UNBALANCED) INPUT2 (BALANCED) WOOFER HIGH OUT1 CHANNEL 1 LOW OUT1 INPUT1 (UNBALANCED) INPUT1 (BALANCED) Non-use Periods: The power cord of time.
PPCX2 Manual 1
Page 4
CONTENTS CONTROLS CONNECTION CONNECTION CABLES SPECIFICATIONS TYPICAL SET-UP SPECIFICATIONS 1 Crossover Type Stereo 2 ways Subwoofer 2 Crossover Range Subwoofer: 50 - 250Hz, 24/10dB 3 Low/High : 250 - 6000Hz, 24/10dB Filter Type (Slope) 2nd order, 12dB/Octave 5 Inputs 6 Type Balanced XLR and unbalanced 1/4" Impedance 100 Kohms Outputs Type Impedance Unbalanced 1/4" 220 Ohms Low Cut Filters Frequency Response 30Hz/ 3dB, 12dB/Octave 20Hz - 25KHz / 1dB Total Harmonic Distortion (THD) Noise < 0.05 % S/N Ratio Fuse > 95 dB 95-120V...
CONTENTS CONTROLS CONNECTION CONNECTION CABLES SPECIFICATIONS TYPICAL SET-UP SPECIFICATIONS 1 Crossover Type Stereo 2 ways Subwoofer 2 Crossover Range Subwoofer: 50 - 250Hz, 24/10dB 3 Low/High : 250 - 6000Hz, 24/10dB Filter Type (Slope) 2nd order, 12dB/Octave 5 Inputs 6 Type Balanced XLR and unbalanced 1/4" Impedance 100 Kohms Outputs Type Impedance Unbalanced 1/4" 220 Ohms Low Cut Filters Frequency Response 30Hz/ 3dB, 12dB/Octave 20Hz - 25KHz / 1dB Total Harmonic Distortion (THD) Noise < 0.05 % S/N Ratio Fuse > 95 dB 95-120V...
PPCX2 Manual 1
Page 5
...: 200mA 250VAC REPLACE FUSE WITH CORRECT TYPE ONLY HIGH OUT2 CHANNEL 2 SUB LOW OUT2 INPUT2 (UNBALANCED) INPUT2 (BALANCED) WOOFER HIGH OUT1 CHANNEL 1 LOW OUT1 INPUT1 (UNBALANCED) INPUT1 (BALANCED) 12 9 11 10 11 11 10 CONTROLS 1 ON/OFF SWITCH Caution: Always turn the Crossover ON before the amplifier, and turn it OFF after the amplifier or transients harmful to the speakers may result. 2 CROSSOVER FREQUENCY CONTROLS: These select the crossover frequencies of each stereo channel with a 12dB...
...: 200mA 250VAC REPLACE FUSE WITH CORRECT TYPE ONLY HIGH OUT2 CHANNEL 2 SUB LOW OUT2 INPUT2 (UNBALANCED) INPUT2 (BALANCED) WOOFER HIGH OUT1 CHANNEL 1 LOW OUT1 INPUT1 (UNBALANCED) INPUT1 (BALANCED) 12 9 11 10 11 11 10 CONTROLS 1 ON/OFF SWITCH Caution: Always turn the Crossover ON before the amplifier, and turn it OFF after the amplifier or transients harmful to the speakers may result. 2 CROSSOVER FREQUENCY CONTROLS: These select the crossover frequencies of each stereo channel with a 12dB...
PPCX2 Manual 1
Page 6
... the signal, to suppress hum, and to your cables are in the upper left comer of problems (faulty contacts, ground hum. Periodically check that your advantage. 5 PHASE SWITCHES: These allow switching the polarity to avoid possible speaker damage. 6 SUB CROSSOVER FREQUENCY CONTROL: This selects the crossover frequency of the SUB WOOFER way. This is always to prevent low frequency subwoofer speaker resonance. With a small screw driver pull/pop out the Fuse...
... the signal, to suppress hum, and to your cables are in the upper left comer of problems (faulty contacts, ground hum. Periodically check that your advantage. 5 PHASE SWITCHES: These allow switching the polarity to avoid possible speaker damage. 6 SUB CROSSOVER FREQUENCY CONTROL: This selects the crossover frequency of the SUB WOOFER way. This is always to prevent low frequency subwoofer speaker resonance. With a small screw driver pull/pop out the Fuse...