Panasonic YE9WKU1 Support and Manuals
Get Help and Manuals for this Panasonic item
This item is in your list!
View All Support Options Below
Free Panasonic YE9WKU1 manuals!
Problems with Panasonic YE9WKU1?
Ask a Question
Free Panasonic YE9WKU1 manuals!
Problems with Panasonic YE9WKU1?
Ask a Question
Popular Panasonic YE9WKU1 Manual Pages
Submittal - Page 3
Product Dimensions
Indoor Unit:
Model
CS-YE9WKU1 CS-YE12WKU1
A
811(31.9) 811(31.9)
Indoor unit(mm/inch) B
292(11.5) 292(11.5)
C
203(7.99) 203(7.99)
5 Air Conditioner Service Manual
3.
Submittal - Page 4
Outdoor Unit:
Air Conditioner Service Manual
Model
CU-YE9WKU1 CU-YE12WKU1
Outdoor unit(mm/inch)
D
E
F
G
I
787(31.0) 498(19.6) 290(11.4) 415(16.3) 225(8.9) 787(31.0 ) 498(19.6 ) 290(11.4 ) 415(16.3) 225(8.9)
J
K
48.5(1.9) 52(2) 48.5(1.9) 52(2)
6
Outdoor Unit Parts List - Page 2
...30
Part Name Grille Top Cover Condenser Outdoor Motor Supporter Outdoor Motor Propeller Fan Left grille supporter Front Plate...Supporter Three-way Valve Electrical Box Cover Terminal Cable clamp1 Cable clamp2 Outdoor PCB Assembly Inductor Capillary Assembly Partition plate Pipe Temp. sensor Discharge Temp. sensor and outdoor Temp. Air Conditioner Service Manual
Outdoor Unit- CU-YE9WKU1...
YE Service Manual - Page 1
Installation
11. Technical Specifications
5. Precaution
2. Wiring diagram
9. Names of parts
7. Product Dimensions
4. Refrigeration cycle diagram
6. Explosion view and parts
10. Important Notice
3. Operation details
8. Trouble shooting
0 Air Conditioner Service Manual
Inverter Air Conditioner
Service Manual
Models
CS-YE9WKU1(indoor unit) CU-YE9WKU1(outdoor unit) CS-...
YE Service Manual - Page 6
Air Conditioner Service Manual
3. Product Dimensions
Indoor Unit:
Model
CS-YE9WKU1 CS-YEWKU1
A 811(31.9) 811(31.9)
Indoor unit(mm/inch) B
292(11.5) 292(11.5)
C 203(7.99) 203(7.99)
5
YE Service Manual - Page 8
Technical Specifications
Technical Specifications
Model
CS-YE9WKU1 (indoor unit) CS-YE12WKU1 (indoor unit) CU-YE9WKU1 (outdoor... 32/70.5
*** Indoor Unit ***
Indoor Motor Indoor air circulation/Hi
Motor Brand
Motor Model(Factory Code)
m3/h
Weilling/Broad-Ocean AC 600
Weilling/Broad-Ocean AC 650
Evaporator
mm
Φ...(cooling/heating) ℃
>=17/=17/
Air Conditioner Service Manual
4.
YE Service Manual - Page 13
...make room temperature closing to set temperature, the compressor will go...8457;)
25℃(77℉)
Setting
Low fan Breeze
34℃(93.2...operates in cooling mode, the set temperature.
(2) Indoor fan motor... shut down compressor and show error code, while the ambient temperature is... closing to the set temperature (ST) ... temperature is less than set temperature.
(2) Outdoor temperature...
YE Service Manual - Page 15
...:
The indoor fan speed is set temperature will stop automatically. 7.
If power supply cut off . Air Conditioner Service Manual
(5) Indoor exchanger overheat protection When Indoor exchanger... Display
When protection display is available, controller will show error code, digital LED shows error code and setting temperature by turns.
If there is operating in SLEEP ...
YE Service Manual - Page 16
...and it always light (ON) while compressor running; Error list
Air Conditioner Service Manual
Failure Type Indoor and outdoor communication fault Outdoor communication failure Indoor room...Model configuration wrong Indoor fan motor fault Outdoor temperature sensor Exhaust temp. TIMER: 2 blink /8 sec RUN: Blink; TIMER: 4 blink /8 sec RUN: Bright; TIMER: 10 blink /8 sec
Digital LED Code...
YE Service Manual - Page 17
Air Conditioner Service Manual
Display on outdoor power source board:
blink time (n)
Failure
1
IPM protection
2
Over voltage /lower voltage
3...
19
Outdoor EEPROM fault
20
Outdoor fan motor protection
21
Indoor fan motor protection
23
System fault
24
Model configuration wrong
25
Indoor room temperature sensor fault
26
Indoor coil temperature sensor fault
27
Indoor EEPROM fault...
YE Service Manual - Page 18
Wiring diagram
MODEL: CS-YE9WKU1/CU-YE9WKU1 . CS-YE12WKU1/CU-YE12WKU1
INDOOR UNIT:
OUTDOOR UNIT
¦È ¦È
¦È
17 Air Conditioner Service Manual
8.
YE Service Manual - Page 20
... CU-YE9WKU1
7
6
Air Conditioner Service Manual
5
4
3
2
1
8 24
23 9
22 21 20 19
18
10
11
17
12
13
14 15
16
No.
sensor and outdoor Temp. sensor Discharge Temp. sensor Base carton Cabinet carton Base foaming Cover foaming
Q'ty
Remark
1 Optional
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1 1
Not shown in explosion view
1
1
1
19 Part...
YE Service Manual - Page 23
...should be selected according to the following specifications sheet. Appliance Amps
Wire Size
5...Installation manual
10.1 Installation Details Connecting pipe length
Model
CS-YE9WKU1/CU-YE9WKU1 CS-YE12WKU1/CU-YE12WKU1
Liquid 1/4 1/4
Pipe size(Inch) Gas 3/8 3/8
Outdoor unit Pipe length is 15 m(49 ft) Max. Indoor unit
Indoor unit Pipe length is 15 m(49 ft) Max. Air Conditioner Service Manual...
YE Service Manual - Page 28
...Service Manual
11. Trouble... heater control Selection of heat and cool-only model Selection of data sheet Selection of Fahrenheit and Centigrade...output
Display pc board
AC rectifier
Temperature or fault code display Emergencyl Switch signal input
Power factor adjustment ...check
11.2 The structure of ODU PCB CS-YE9WKU1/CU-YE9WKU1;CS-YE12WKU1/CU-YE12WKU1
Indicator
DC motor
Compressor ...