Service Manual - Page 1
... no refrigerant leakage during the installation or repairing of potential dangers in serious injury or death. It does not contain warnings or cautions to advise non-technical individuals of refrigerant circuit.
© Panasonic Corporation 2013.
Any attempt to service a product. Order No: PAPAMY1305056CE
Air Conditioner
Indoor Unit CS-XE9PKUA CS-XE12PKUA
Outdoor Unit CU-XE9PKUA...
Service Manual - Page 3
.... Do not modify the machine, part, material during repairing service.
2. Exchange the whole wiring unit.
3. If installation is less than 1/32" (0.8 mm). Install at veranda of equipment breakdown.
Clamp the cable so that the amount of lightning rod and telephone.
Do not install outdoor unit near handrail of the instruction will cause the set 's weight. Poor contact, poor...
Service Manual - Page 4
... in explosion, injury etc.)
21. Ventilate if there is no leakage or refrigerant gas. Using of installation or service, confirm there is refrigerant gas leakage during repairing a refrigerant parts. If drainage is over-tightened, after a long period, the flare may need two people to a circuit breaker for permanent connection.
8. It may enter the room...
Service Manual - Page 11
...
Environment Protection o Non-ozone depletion substances refrigerant (R410A)
Long Installation Piping o Long piping up to 65.6ft (20 meters) during single split connection...mode to reach the desired room temperature quickly o 24-hour timer setting o RFP (Room Freeze Protection) operation is designed to circulate ...Serviceability Improvement o Breakdown Self Diagnosis function
`
11 3.
Service Manual - Page 30
...of a charging set and the service port of the 3-way valve.
2 Connect the micron gauge between vacuum pump and service port of outdoor...repair location of leak. - If the leak does not stop when the connections are tightened further, continue working from the service port of the 3-way valve. 6 Tighten the service port caps of the 3-way valve at a torque of the valves to check for installation...
Service Manual - Page 33
... is judged. For the 1st judgment
o If indoor intake temperature - Manual Fan Speed [Cooling, Dry] Fan motor's number of rotation is determined according to remote control setting. Lo
33 remote control setting temperature < -3.6°F (-2°C), HEAT mode is decided. remote control setting temperature < 5.4°F (3°C), maintain with speed of rotation is determined...
Service Manual - Page 35
...;C)
During above condition, when indoor heat exchanger temperature is below 41°F (5°C), the outdoor fan will stop . Manual vertical airflow direction can be automatic (angles of airflow direction can be set using remote control, the vane will shift to close position.
35 When the air conditioner is stopped using remote...
Service Manual - Page 36
... "on" activates, quiet operation maintains. After off , when on back, quiet operation is not memorised.
Control contents o Fan speed manual Fan speed is changed from normal setting to quiet setting of respective fan speed. POWERFUL/QUIET LED illuminates. 12.4.2 Horizontal Airflow
The horizontal airflow direction louvers can be adjusted...
Service Manual - Page 44
... (AC) exceeds X value, the frequency instructed for compressor operation will be decreased.
2 If the running current exceeds...Model Operation Mode Cooling / Soft Dry (A) Cooling / Soft Dry (B)
Heating Cooling / Soft Dry (C)
XE9PKUA
X (A)
Y (A)
6.48
15.00
6.48
15.00
7.48
15.00
6.48
15.00
XE12PKUA... restart after 3 minutes. 2 If the set value is cut off and on again. This phenomenon...
Service Manual - Page 48
...will be used together with remote control to set / change remote control transmission code, short or open jumpers at the fifth seconds, in order to the EEPROM. Servicing Mode
14.1 Auto OFF/ON Button
1 ...seconds to identify the starting of indoor unit. There are 2 or more indoor units installed nearby together.
This operation can be activated immediately once the Auto OFF/ON button ...
Installation Manual - Page 7
.... If the leak stops when the piping connections are retightened, repair location of leak. - Do not release refrigerant during piping work... a charging set and the service port of the 3-way valve.
2 Connect the micron gauge between vacuum pump and service port of ...WHEN INSTALLING AN AIR CONDITIONER, BE SURE TO EVACUATE THE AIR INSIDE THE INDOOR UNIT AND PIPES in accordance with local electric codes....
Operating Manual - Page 3
...guide
1 3
Inserting the batteries
2
1 Pull out the back cover of
remote control
2 Insert AAA or R03 batteries (can be used ~ 1 year)
3 Close the cover
2 3 Clock setting
TIMER
ON
SET
1 Press CLOCK
1
2
3
2 Set the time
OFF
CANCEL
1
AC RC
SET... illustrations in this manual are subject to use 6-7 To learn more 8-9 Cleaning instructions 10 Troubleshooting 11 Information 12
...
Operating Manual - Page 7
... by
ON
pressing or to select respective or OFF then press . For clock setting, please refer to Quick guide. See "To learn more..." How to use
English
Note
POWERFUL/ AUTO
ECONAVI
QUIET...3
SET
1
2
3
OFF
CANCEL
AC
C
1 Select ON or OFF timer • Each time pressed:
Cancel
Example: OFF at the same time.
To adjust horizontal airflow direction • Manually adjustable...
Operating Manual - Page 12
...interference in the European Union. Installation of Old Equipment and used ...part 15 of the FCC Rules. Industry Canada Notice
This Class B digital apparatus complies with the instructions...ciency. Models Number
CS-XE9PKUA / CU-XE9PKUA CS-XE12PKUA / CU-XE12PKUA
The above listed models have been...this case it complies with the requirement set by the party responsible for energy ef...
Submittal Sheet - Page 1
... Self-Diagnosis Air Filter
Standard Optional
Microprocessor LCD Wireless Type IC Thermostat Manual Automatic Built-In Built-In Washable, One-touch
Operating Range Cooling (Max...Aluminum Fin & Copper Tube Slit Plate - O.D. Split System Submittal Data
Indoor: CS-XE12PKUA Outdoor: CU-XE12PKUA Wall Mounted Air Conditioners
Job Name: Location: Engineer: Submitted to: Submitted by: Reference:...
Panasonic XE12PKUA Reviews
Do you have an experience with the Panasonic XE12PKUA that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Panasonic yet.
Earn 750 points for your review!