Panasonic WU-216MF2U9 Support and Manuals

Get Help and Manuals for this Panasonic item

View All Support Options Below
Free Panasonic WU-216MF2U9 manuals!
Problems with Panasonic WU-216MF2U9?

Ask a Question

Popular Panasonic WU-216MF2U9 Manual Pages

- Service Manual - Page 2

Follow each installation or repair step exactly as possible. • Apply refrigerant lubricant to install or service the system so it operates safely and efficiently. This air conditioner shall be responsible for improper installation or maintenance service, including failure to follow the instructions in personal injury or product or property damage. Pay close attention to a hazard...
- Service Manual - Page 78

...-control settings) using the service ports at the liquid tube side, suction tube side and discharge tube side ball valves. END 9 2 - 10 Refrigerant Recovery Procedures (Indoor Unit) Fig. 3-b The flowchart below shows the refrigerant recovery procedures you must follow when replacing or repairing the indoor unit due to trouble in the Open ball valve "Installation Instructions" on...
- Service Manual - Page 80

... (outdoor unit serial communication signal error) occurs and the unit will ... 2 - 12 Quickly connect each part to prevent air from entering the tube... circuit must be isolated. (6) Change the setting of refrigerant recovery, follow the instructions that each connection port. (10) Use hoses... suction tube 5 service port, the discharge tube service port and the liquid tube service port in the ...
- Service Manual - Page 124

...Settings Function 3WAY VRF SYSTEM Remote Controller Functions Item code 03 04 Item Central control address Operating mode priority change Enabled only in 3WAY VRF System heat-pump models. 1 With indoor units that are installed in combination with an outdoor unit model... subsequently operated. Used when setting the central control address manually from a specific remote controller - When ...
- Service Manual - Page 129

... input (differential pressure switch input) Filter (CN70) input 0001 Alarm input (for trouble input about air cleaner or similar device) switching 0002 Humidifier input (Operates linked with...reminder 0002 Fire prevention input 8 4 - 11 9 Detailed Settings Function 3WAY VRF SYSTEM Remote Controller Functions Item code (1B) Item Forced thermostat ON time Cooling discharge temperature shift ...
- Service Manual - Page 131

... 4 and stay Flap Separately". Detailed Settings Function 3WAY VRF SYSTEM Remote Controller Functions Item code Item No. Setting data Description DC fan tap operating mode Purpose 0000 Standard Standard (setting at shipment) Fan tap setting (Fan tap change in order to prevent drop in air discharge caused by filter installation) 0001 0003 High ceiling use For...
- Service Manual - Page 132

...shipping from the factory. These must be set after installation if auto address setting is not performed. This setting establishes a shift temperature for difference between the room temperature and the temperature set at which an indoor unit is replaced during servicing. Detailed Settings Function 3WAY VRF SYSTEM Remote Controller Functions Item code 10 11 12 13 14 Item Unit...
- Service Manual - Page 133

...OFF of use this display from remote controller stop of shipping. Detailed Settings Function 3WAY VRF SYSTEM Remote Controller Functions Item code Item Description 1F (Upper limit) 20 (Lower limit) Cooling 21 ... this setting is used when the T10 terminal is displayed. However, this setting is ON, however it is 35 OFF reminder function for humidifying. It is possible to install a ...
- Service Manual - Page 154

... No response from outdoor unit. E31 4 Improper setting Indoor unit model does not match with the setting on R1-R2 link. L06 Group control wiring is detected for outdoor ambient air temperature has failure. (TO) F08 Continued 9 5 - 2 cation errors Mis-setting error signal from sub outdoor unit. E06 Improper setting Indoor unit address is duplicating. E08 Two...
- Service Manual - Page 159

... the blinking on the remote controller. E15 Alarm 4 Alarm code E15 Alarm meaning Fewer indoor units are completed. Probable cause (1) The number of indoor units set ," or other trouble that occurs before initial communications are completed. Example - Auto address setting was started when auto address setting was in progress at the outdoor unit where it...
- Service Manual - Page 181

... wiring. Fan motor start , or when inverter compressor lock occurs, there is locked, replace the fan motor. Check the fan motor wiring, the Hall IC wiring, and the ...failure and a Fan PCB failure. 3. 3WAY Alarm Codes 3WAY VRF SYSTEM Trouble Diagnosis P22 Alarm (U-72MF2U94 / U-96MF2U94 / U-120MF2U94 / U-144MF2U94) Alarm code P22 Alarm meaning Alarm conditions Probable cause Check Fan...
- Service Manual - Page 203

... unit error data 2. RC setting mode 4.Test run Unit no. 3-1 Code no ." Next 1 2. The indoor unit fan operates only at the selected If you wish to the remote controller can be checked. 3. Simple settings" on...unit. The "Simple settings" screen appears on the LCD display. 3. Service contact 3. Press and hold the button and button for 4 seconds or longer (simple settings mode). 2. Press...
- Technical Data Manual - Page 2

... a torque wrench for a leak-free connection. • Check carefully for improper installation or maintenance service, including failure to refrigerant leakages. • Ventilate the room immediately, in this manual. Provide snow vents. When Connecting Refrigerant Tubing • Pay particular attention to follow the instructions in the event that is refrigerant gas leaks during the...
- Installation Manual - Page 2

... service, including failure to support or hold the unit, and select a location for specified refrigerant (R410A) in no way be responsible for the outdoor unit. Provide a suitable air baffle. ...In a Snowy Area (for additional instructions. Please Read Before Starting This air conditioning system meets strict safety and operating standards. For safe installation and trouble...
- Installation Manual - Page 6

... Indoor and Outdoor Units 5-3. Preparing for Installation 1-5. Auto Address Setting 7-6. Installing the Outdoor Unit 3-3. Prepare the Tubing 3-5. ELECTRICAL WIRING 29 Please Read Before Starting Check of Limit Density 1-12. SELECTING THE INSTALLATION SITE. . . . . . 18 2-1. Dimensions of Joints 1-8. Tools Required for earlier models 1. Straight Equivalent Length of Wind...

Panasonic WU-216MF2U9 Reviews

Do you have an experience with the Panasonic WU-216MF2U9 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Panasonic yet.

Ask a New Question
Use the box below to post a new question about Panasonic WU-216MF2U9.
Manuals / Documents
Download any of our Panasonic WU-216MF2U9 manuals for free!

We have the following 5 documents available for the Panasonic WU-216MF2U9:
  • - Technical Data Manual
  • - Service Manual
  • - Installation Manual
  • - Operation Manual
  • - Submittal

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Panasonic Manuals

Find free Panasonic WU-216MF2U9 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Panasonic Reviews

View thousands of Panasonic WU-216MF2U9 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Panasonic customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Panasonic customer service rankings, employee comments and much more from our sister site.

Panasonic Recalls

Find comprehensive Panasonic recall information updated hourly on RecallOwl.com.