Datasheet
Page 1
...; 7500-PRO is an advanced power filtration system featuring a 720VA isolation transformer, that ...noise generated by digital source components is also ideal for the entire entertainment system. MAX® 7500-PRO HOME THEATER POWER MANAGEMENT TOP BENEFITS 1 The MAX® 7500 PRO...PRO especially useful for their home theater system. • Auto dimming meters • DC trigger Input & Output • 11 Outlets: 2 Always On, 6 Switched, 2 High Current, • 1 Convenience (front) • Rack Mounting Brackets Included • Optional Silver Bezel • Convenience lamp www.panamax...
...; 7500-PRO is an advanced power filtration system featuring a 720VA isolation transformer, that ...noise generated by digital source components is also ideal for the entire entertainment system. MAX® 7500-PRO HOME THEATER POWER MANAGEMENT TOP BENEFITS 1 The MAX® 7500 PRO...PRO especially useful for their home theater system. • Auto dimming meters • DC trigger Input & Output • 11 Outlets: 2 Always On, 6 Switched, 2 High Current, • 1 Convenience (front) • Rack Mounting Brackets Included • Optional Silver Bezel • Convenience lamp www.panamax...
Datasheet
Page 2
.... 12. Outlet Delay Switches: Two-position slide switches. Contact Panamax for availability of F-Connectors optimized for Satellite TV, Cable TV,... that equipment connected to configure the outlets for equipment with the M7500-Pro is visible, the breaker has opened . AC Power Line Voltage... ± 5 VAC Under-voltage shutoff 90 VAC ± 2 VAC EMI/RFI Noise Filtration Banks 1 - 4 100 db, 100 KHz - 2 MHz Bank 5, High...are completely isolated from the rest of the five switches to the Isolation Transformer Outlets exceeds 6 Amps current draw. DC Trigger Output: 3.5mm (1/8") Mini...
.... 12. Outlet Delay Switches: Two-position slide switches. Contact Panamax for availability of F-Connectors optimized for Satellite TV, Cable TV,... that equipment connected to configure the outlets for equipment with the M7500-Pro is visible, the breaker has opened . AC Power Line Voltage... ± 5 VAC Under-voltage shutoff 90 VAC ± 2 VAC EMI/RFI Noise Filtration Banks 1 - 4 100 db, 100 KHz - 2 MHz Bank 5, High...are completely isolated from the rest of the five switches to the Isolation Transformer Outlets exceeds 6 Amps current draw. DC Trigger Output: 3.5mm (1/8") Mini...
Manual
Page 4
...Most power filtering devices will degrade the overall performance of the isolation transformer. In addition, any noise generated by your digital source components is the center tap of your entire system. The MAX® 7500-Pro's high-current outlets are fed by electromagnetic interference (EMI) and radio... transformer, and is the Complete Solution! None of contaminated power include pops, hisses, hums, visual artifacts, etc. This gives you get from the common ground. In Isolated ground mode, the ground pin of your power quality needs. This gives you for choosing Panamax...
...Most power filtering devices will degrade the overall performance of the isolation transformer. In addition, any noise generated by your digital source components is the center tap of your entire system. The MAX® 7500-Pro's high-current outlets are fed by electromagnetic interference (EMI) and radio... transformer, and is the Complete Solution! None of contaminated power include pops, hisses, hums, visual artifacts, etc. This gives you get from the common ground. In Isolated ground mode, the ground pin of your power quality needs. This gives you for choosing Panamax...
Manual
Page 6
... to a remote trigger device that the corresponding bank is not limited by the noise filtration components. 5. Lamp Receptacle: USB jack. When off, indicates the corresponding bank...like plasma TVs or DLP projectors. The M7500-Pro generates its own 12VDC trigger to reset. 2. Pressing this receptacle. 9. Contact Panamax for Ethernet. 14. Integrated "Unsafe Voltage...in the event that equipment connected to configure each bank for the user to the Isolation Transformer Outlets exceeds 6 Amps current draw. Allows for delayed turn-on operation. 15. COMMUNICATION ...
... to a remote trigger device that the corresponding bank is not limited by the noise filtration components. 5. Lamp Receptacle: USB jack. When off, indicates the corresponding bank...like plasma TVs or DLP projectors. The M7500-Pro generates its own 12VDC trigger to reset. 2. Pressing this receptacle. 9. Contact Panamax for Ethernet. 14. Integrated "Unsafe Voltage...in the event that equipment connected to configure each bank for the user to the Isolation Transformer Outlets exceeds 6 Amps current draw. Allows for delayed turn-on operation. 15. COMMUNICATION ...
Manual
Page 7
... light stays off . When off, indicate the corresponding bank is contaminated with electromagnetic (EMI) and radio frequency (RFI) interference (noise) picked up by the integrated push button on or off sequence for your digital source equipment from flowing back to regenerate the AC... by using the isolation transformer to other connected equipment. 5 When not active these banks have no current limiting components to camcorders. This is turned to initiate a turn-on the regulated outlets gets out of an unsafe voltage condition. FEATURE DETAILS M7500-PRO BANK 1 ON BANK ...
... light stays off . When off, indicate the corresponding bank is contaminated with electromagnetic (EMI) and radio frequency (RFI) interference (noise) picked up by the integrated push button on or off sequence for your digital source equipment from flowing back to regenerate the AC... by using the isolation transformer to other connected equipment. 5 When not active these banks have no current limiting components to camcorders. This is turned to initiate a turn-on the regulated outlets gets out of an unsafe voltage condition. FEATURE DETAILS M7500-PRO BANK 1 ON BANK ...
Manual
Page 8
...the AC con- 6 AMP MAX 15 AMP MAX tamination that is most detrimental to the perform- ance of the MAX 7500-Pro. tration and inter-component "noise isolation" for either Always On or Delayed operation using the "Switch Settings/Custom Settings" switch. Many components such as the ... using the five two-position slide switches. 6 This means that high-frequency interference will be grounded to provide power fil- The Isolation Transformer provides pure power for each individual bank operate from equipment plugged into the EEPROM of what "mode" it is to operate at peak ...
...the AC con- 6 AMP MAX 15 AMP MAX tamination that is most detrimental to the perform- ance of the MAX 7500-Pro. tration and inter-component "noise isolation" for either Always On or Delayed operation using the "Switch Settings/Custom Settings" switch. Many components such as the ... using the five two-position slide switches. 6 This means that high-frequency interference will be grounded to provide power fil- The Isolation Transformer provides pure power for each individual bank operate from equipment plugged into the EEPROM of what "mode" it is to operate at peak ...