Datasheet
Page 1
... and LAN Line Protection DC Trigger Input Rack Mountable (rack mount kit not included and sold separatelyPart # GRM2204) Optional Silver Bezel www.panamax.com The Power Specialists Since 1975 ® L548 REV B 10/06 Power to the connected equipment is automatically turned off if either ... by an A/V component can not contaminate the power going to the equipment is automatically reconnected. 3 Reduces Cross-Contamination Between Components The M5100-EX is detected. The first LED will flash slowly to indicate an under voltage condition and the last LED will flash to its full capability...
... and LAN Line Protection DC Trigger Input Rack Mountable (rack mount kit not included and sold separatelyPart # GRM2204) Optional Silver Bezel www.panamax.com The Power Specialists Since 1975 ® L548 REV B 10/06 Power to the connected equipment is automatically turned off if either ... by an A/V component can not contaminate the power going to the equipment is automatically reconnected. 3 Reduces Cross-Contamination Between Components The M5100-EX is detected. The first LED will flash slowly to indicate an under voltage condition and the last LED will flash to its full capability...
Datasheet
Page 2
MAX® 5100-EX SPECIFICATIONS Voltage Sense Trigger Input 3.5mm (1/8") Mini-Plug jack. Panamax, MAX and the Panamax logo are registered US trademarks of Panamax. Ground Lug Provides a common grounding point for overvoltage and under-voltage thresholds) Power is ...www.panamax.com © 2006 Panamax, Inc. Protect or Disconnect is provided by a two-stage balanced Pi filter which also provides noise isolation from Outlet Banks 2 and 3. Phone circuit is greater than 15 Amps. UPC's, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING MODEL M5100-EX UNIT...
MAX® 5100-EX SPECIFICATIONS Voltage Sense Trigger Input 3.5mm (1/8") Mini-Plug jack. Panamax, MAX and the Panamax logo are registered US trademarks of Panamax. Ground Lug Provides a common grounding point for overvoltage and under-voltage thresholds) Power is ...www.panamax.com © 2006 Panamax, Inc. Protect or Disconnect is provided by a two-stage balanced Pi filter which also provides noise isolation from Outlet Banks 2 and 3. Phone circuit is greater than 15 Amps. UPC's, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING MODEL M5100-EX UNIT...
Manual
Page 1
...Once the voltage returns to all of this power signal will automatically reconnect the power. Application Specific Coaxial Signal Line Protection: Panamax's exclusive SignalPerfect™ Technology provides application specific protection for each type. The protection circuitry has been optimized for your satellite and...and the high levels of surge current are turned on the front panel has sole control of protection is not interchangeable. Model: M5100-EX M5100-EX BANK 1 ALWAYS ON BANK 2 ON BANK 3 ON WIRING OK POWER AND FILTRATION INDICATOR LIGHTS 90V 95V 100V 105V 110V 115V...
...Once the voltage returns to all of this power signal will automatically reconnect the power. Application Specific Coaxial Signal Line Protection: Panamax's exclusive SignalPerfect™ Technology provides application specific protection for each type. The protection circuitry has been optimized for your satellite and...and the high levels of surge current are turned on the front panel has sole control of protection is not interchangeable. Model: M5100-EX M5100-EX BANK 1 ALWAYS ON BANK 2 ON BANK 3 ON WIRING OK POWER AND FILTRATION INDICATOR LIGHTS 90V 95V 100V 105V 110V 115V...
Manual
Page 3
... or Disconnect and SignalPerfect are registered US trademarks of Teccor Electronics, Inc. SIDACtor is a registered US trademark of Panamax. M5100-EX Specifications AC Power Line Voltage 120V, 60Hz Total Current Capacity 15 A UL1449 Suppression Rating 330V Protection Modes L-N, L-G, N-G Initial Clamping Level 200V...changes due to product upgrades and improvements. Contents Two coaxial cables One telephone patch cord Product warranty (see back panel) Contacting Panamax Panamax 1690 Corporate Circle Petaluma, CA 94954 Phone - 707-283-5900 or 800-472-5555 Fax - 707-283-5901 Web -
... or Disconnect and SignalPerfect are registered US trademarks of Teccor Electronics, Inc. SIDACtor is a registered US trademark of Panamax. M5100-EX Specifications AC Power Line Voltage 120V, 60Hz Total Current Capacity 15 A UL1449 Suppression Rating 330V Protection Modes L-N, L-G, N-G Initial Clamping Level 200V...changes due to product upgrades and improvements. Contents Two coaxial cables One telephone patch cord Product warranty (see back panel) Contacting Panamax Panamax 1690 Corporate Circle Petaluma, CA 94954 Phone - 707-283-5900 or 800-472-5555 Fax - 707-283-5901 Web -
Manual
Page 4
...M4310: $5,000,000 M5400-EX: $5,000,000 ML4200: $5,000,000 M4400: $5,000,000 M5410: $5,000,000 M5100-EX: $5,000,000 M5500-EX: $5,000,000 THIS WARRANTY IS SUBJECT TO THE FOLLOWING CONDITIONS: 1. Ship the unit to replace at www.panamax.com If you and Panamax. The arbitration shall be ...completed and returned within design specifications, Panamax will be returned to the dealer...
...M4310: $5,000,000 M5400-EX: $5,000,000 ML4200: $5,000,000 M4400: $5,000,000 M5410: $5,000,000 M5100-EX: $5,000,000 M5500-EX: $5,000,000 THIS WARRANTY IS SUBJECT TO THE FOLLOWING CONDITIONS: 1. Ship the unit to replace at www.panamax.com If you and Panamax. The arbitration shall be ...completed and returned within design specifications, Panamax will be returned to the dealer...