Installation Guide
Page 1
30" AND 36" (76.2 AND 91.4 CM) WALL-MOUNT CANOPY RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301 or visit our website at ...
30" AND 36" (76.2 AND 91.4 CM) WALL-MOUNT CANOPY RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301 or visit our website at ...
Installation Guide
Page 2
... Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 9 Complete Installation 10 RANGE HOOD USE 10 Range Hood Controls 10 RANGE HOOD CARE 11 Cleaning 11 WIRING DIAGRAM 12 ASSISTANCE OR SERVICE 13 In the U.S.A...25 SCHÉMA DE CÂBLAGE 26 ASSISTANCE OU SERVICE 27 Au Canada 27 Accessoires 27 GARANTIE 27 RANGE HOOD SAFETY Your safety and the safety of California to cause cancer. WARNING You can happen if the instructions are very ...
... Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 9 Complete Installation 10 RANGE HOOD USE 10 Range Hood Controls 10 RANGE HOOD CARE 11 Cleaning 11 WIRING DIAGRAM 12 ASSISTANCE OR SERVICE 13 In the U.S.A...25 SCHÉMA DE CÂBLAGE 26 ASSISTANCE OU SERVICE 27 Au Canada 27 Accessoires 27 GARANTIE 27 RANGE HOOD SAFETY Your safety and the safety of California to cause cancer. WARNING You can happen if the instructions are very ...
Installation Guide
Page 4
... It is recommended for use with cooktops with installation clearances specified on the rear wall of 60,000 BTUs or less. Canopy hood location should be sealed. Given dimensions provide minimum clearance. See "Electrical Requirements" section. Recirculation Kit Part Number W10294733 is not ...and canopy glass already installed ■■ Vent transition with any tools listed here. Have a qualified technician install the range hood. The canopy hood is determined by ceiling height. All openings in the "Connect Vent System" section. Read and follow the instructions provided with...
... It is recommended for use with cooktops with installation clearances specified on the rear wall of 60,000 BTUs or less. Canopy hood location should be sealed. Given dimensions provide minimum clearance. See "Electrical Requirements" section. Recirculation Kit Part Number W10294733 is not ...and canopy glass already installed ■■ Vent transition with any tools listed here. Have a qualified technician install the range hood. The canopy hood is determined by ceiling height. All openings in the "Connect Vent System" section. Read and follow the instructions provided with...
Installation Guide
Page 5
.... ceiling height Electric cooking surface 7' 4" (2.23 m) 9' 9" (2.97 m) Gas cooking surface 7' 7" (2.31 m) 9' 9" (2.97 m) NOTE: The range hood chimneys are adjustable and designed to provide efficient performance. For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number EXTKIT10ES is recommended. Venting Requirements (vented...An additional back draft damper should be installed to where the vent system enters the heated portion of the range hood and the cooking surface. See the following chart. ceiling height Max. ceiling height Max. Side cabinet 30" (...
.... ceiling height Electric cooking surface 7' 4" (2.23 m) 9' 9" (2.97 m) Gas cooking surface 7' 7" (2.31 m) 9' 9" (2.97 m) NOTE: The range hood chimneys are adjustable and designed to provide efficient performance. For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number EXTKIT10ES is recommended. Venting Requirements (vented...An additional back draft damper should be installed to where the vent system enters the heated portion of the range hood and the cooking surface. See the following chart. ceiling height Max. ceiling height Max. Side cabinet 30" (...
Installation Guide
Page 6
... locale. To vent through the roof or wall. Deflector B. 6" (15.2 cm) round vent To calculate the length of the range hood. ■■ Wire sizes must conform with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical... B B A A. wall cap 8 ft (2.4 m) straight Length of copper wire using ventilation systems greater than specified CFM of the above the hood. Flexible vent creates back pressure and air turbulence that the electrical installation is used in your area. Connect the aluminum wiring to aluminum. The...
... locale. To vent through the roof or wall. Deflector B. 6" (15.2 cm) round vent To calculate the length of the range hood. ■■ Wire sizes must conform with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical... B B A A. wall cap 8 ft (2.4 m) straight Length of copper wire using ventilation systems greater than specified CFM of the above the hood. Flexible vent creates back pressure and air turbulence that the electrical installation is used in your area. Connect the aluminum wiring to aluminum. The...
Installation Guide
Page 7
... Select a flat surface for the home power supply cable and drill a 11/4" (3.2 cm) hole at this location. 3. Failure to slide range hood into wood. Remove the template. 5. For wood, drill 3/16" (4.8 mm) pilot holes at all openings. 7 Use the optional wall anchors...reconnect power until the wall anchors are being used. 6. Place covering over that the vent system be installed. 2. Mounting height reference (hood bottom line) Vent Cover Bracket Installation 1. Ceiling B. Centerline Complete Preparation 1. Disconnect power. 2. Select a mounting height between the wall ...
... Select a flat surface for the home power supply cable and drill a 11/4" (3.2 cm) hole at this location. 3. Failure to slide range hood into wood. Remove the template. 5. For wood, drill 3/16" (4.8 mm) pilot holes at all openings. 7 Use the optional wall anchors...reconnect power until the wall anchors are being used. 6. Place covering over that the vent system be installed. 2. Mounting height reference (hood bottom line) Vent Cover Bracket Installation 1. Ceiling B. Centerline Complete Preparation 1. Disconnect power. 2. Select a mounting height between the wall ...
Installation Guide
Page 8
... the duct cover bracket using (4) 4.2 x 8 mm screws. Connect Vent System 1. Measure from range hood and metal filters. 1. Exhaust outlet 3. Slide the duct onto the bottom of hood (if removed for shipping) with (2) 3.5 x 9.5 mm sheet metal screws. Seal connections with clamps....the mounting slots on top of the air deflector. 6. Mounting screws B. Mounting slots C. Lower mounting screws 2. Remove the grease filter. See "Range Hood Care" section. 3. Seal connection with vent clamps. 8 A B C A. Duct cover bracket 2. Vent clamp C. Cut the duct to cut vent...
... the duct cover bracket using (4) 4.2 x 8 mm screws. Connect Vent System 1. Measure from range hood and metal filters. 1. Exhaust outlet 3. Slide the duct onto the bottom of hood (if removed for shipping) with (2) 3.5 x 9.5 mm sheet metal screws. Seal connections with clamps....the mounting slots on top of the air deflector. 6. Mounting screws B. Mounting slots C. Lower mounting screws 2. Remove the grease filter. See "Range Hood Care" section. 3. Seal connection with vent clamps. 8 A B C A. Duct cover bracket 2. Vent clamp C. Cut the duct to cut vent...
Installation Guide
Page 9
... or electrical shock. 7. Failure to green and yellow ground wire in terminal box using both upper and lower vent covers, push lower cover down onto hood, and then lift upper cover to hide slots. 9 B A. A B C FE C D G A. Terminal box 5. Remove terminal box cover. 3. Reconnect power. Terminal box cover 4. White wires E. UL listed wire...
... or electrical shock. 7. Failure to green and yellow ground wire in terminal box using both upper and lower vent covers, push lower cover down onto hood, and then lift upper cover to hide slots. 9 B A. A B C FE C D G A. Terminal box 5. Remove terminal box cover. 3. Reconnect power. Terminal box cover 4. White wires E. UL listed wire...
Installation Guide
Page 10
...holes B. Grease filter release handle 10 For non-vented (recirculating) installations only, install charcoal filters over metal grease filter. RANGE HOOD USE The range hood is complete to remove smoke, cooking vapors, and odors from the cooktop area. The speed can be changed anytime during fan ... and allow it to operate several minutes after the cooking is designed to clear all smoke and odors from your new range hood, read the "Range Hood Use" section. Blower speed maximum button B. On/Off light button C Operating the light The On/Off light button controls...
...holes B. Grease filter release handle 10 For non-vented (recirculating) installations only, install charcoal filters over metal grease filter. RANGE HOOD USE The range hood is complete to remove smoke, cooking vapors, and odors from the cooktop area. The speed can be changed anytime during fan ... and allow it to operate several minutes after the cooking is designed to clear all smoke and odors from your new range hood, read the "Range Hood Use" section. Blower speed maximum button B. On/Off light button C Operating the light The On/Off light button controls...
Installation Guide
Page 11
... to latch into top side of metal filter. Replace with normal use steel wool or soap-filled scouring pads. Bend spring clips away from range hood. Remove the filter by a service technician only. A 4. A. Insert aluminum filter into place to secure the charcoal filter to 6 months with Charcoal Filter Kit Number ... or hot detergent solution. 3. Push up to the metal filter. Wash metal filter as needed in this section. 2. Place charcoal filter into place. 5. RANGE HOOD CARE Cleaning IMPORTANT: Clean the hood and grease filters frequently according to avoid water marks.
... to latch into top side of metal filter. Replace with normal use steel wool or soap-filled scouring pads. Bend spring clips away from range hood. Remove the filter by a service technician only. A 4. A. Insert aluminum filter into place to secure the charcoal filter to 6 months with Charcoal Filter Kit Number ... or hot detergent solution. 3. Push up to the metal filter. Wash metal filter as needed in this section. 2. Place charcoal filter into place. 5. RANGE HOOD CARE Cleaning IMPORTANT: Clean the hood and grease filters frequently according to avoid water marks.
Dimension Guide
Page 1
... on the distance "X" between the elbows if more than 1 elbow is required. ceiling height 9' 9" (2.97 m) 9' 9" (2.97 m) NOTE: The range hood chimneys are for planning purposes only. Plastic or metal foil vent is not recommended. ■■ The length of vent system and number of 2 Ref.... 30" (76.2 cm) and 36" (91.4 cm) Wall-Mount Canopy Range Hood PRODUCT MODEL NUMBERS WVW51UC0F WVW51UC6F ELECTRICAL REQUIREMENTS A 120-volt, 60-Hz., AC-only, 15-amp, fused electrical circuit is used. ■■ Do not install 2 elbows...
... on the distance "X" between the elbows if more than 1 elbow is required. ceiling height 9' 9" (2.97 m) 9' 9" (2.97 m) NOTE: The range hood chimneys are for planning purposes only. Plastic or metal foil vent is not recommended. ■■ The length of vent system and number of 2 Ref.... 30" (76.2 cm) and 36" (91.4 cm) Wall-Mount Canopy Range Hood PRODUCT MODEL NUMBERS WVW51UC0F WVW51UC6F ELECTRICAL REQUIREMENTS A 120-volt, 60-Hz., AC-only, 15-amp, fused electrical circuit is used. ■■ Do not install 2 elbows...
Dimension Guide
Page 2
...m) = 13 ft (3.9 m) Because Whirlpool Corporation includes a continues commitment to improve our products, we reserve the right to change without notice. The hood exhaust opening is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance. To vent through a wall, a 90°...of 35 ft (10.7 m). 1 - 90° Elbow 1 - VENTING METHODS This canopy hood is needed for installation (not included). Specifications subject to the outside, the hood can terminate either through the top grille. Page 2 of the system you need, add the ...
...m) = 13 ft (3.9 m) Because Whirlpool Corporation includes a continues commitment to improve our products, we reserve the right to change without notice. The hood exhaust opening is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance. To vent through a wall, a 90°...of 35 ft (10.7 m). 1 - 90° Elbow 1 - VENTING METHODS This canopy hood is needed for installation (not included). Specifications subject to the outside, the hood can terminate either through the top grille. Page 2 of the system you need, add the ...