Dimension Guide
Page 1
Electric MGD7230HW - Gas Metallic Slate Available MED7230HC - Gas 43 1∕8" Height W11412670B 29 7∕8" Depth 27" Width Dimension Guide Maytag® Dryer with Extra Power and Advanced Moisture Sensing - 7.4 cu. Electric MGD7230HC - White Available MED7230HW - ft.
Electric MGD7230HW - Gas Metallic Slate Available MED7230HC - Gas 43 1∕8" Height W11412670B 29 7∕8" Depth 27" Width Dimension Guide Maytag® Dryer with Extra Power and Advanced Moisture Sensing - 7.4 cu. Electric MGD7230HC - White Available MED7230HW - ft.
Dimension Guide
Page 4
... and servicing. Ƀ Additional clearances might be considered. 14" max (356 mm) 18" (460 mm) 3" (76 mm) 48 in the top and bottom of the dryer is recommended to reduce noise transfer. Ƀ For closet installation, with a door, minimum ventilation openings in .2 (310 cm ) 242"42/i2n4.2"2 3" (155 cm ) (76 mm...
... and servicing. Ƀ Additional clearances might be considered. 14" max (356 mm) 18" (460 mm) 3" (76 mm) 48 in the top and bottom of the dryer is recommended to reduce noise transfer. Ƀ For closet installation, with a door, minimum ventilation openings in .2 (310 cm ) 242"42/i2n4.2"2 3" (155 cm ) (76 mm...
Owners Manual 1
Page 2
The dryer must conform with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, ... Natural Gas and Propane Installation Code, CSA B149.1. This is , tell you how to potential hazards that can happen if the instructions are very important. DRYER SAFETY Your safety and the safety of others .
The dryer must conform with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, ... Natural Gas and Propane Installation Code, CSA B149.1. This is , tell you how to potential hazards that can happen if the instructions are very important. DRYER SAFETY Your safety and the safety of others .
Owners Manual 1
Page 4
...(60°C) minimum. The cord should contain: ■ A UL listed 30 A power supply cord, rated 120/240 V minimum, with clothes dryers. Check existing electrical supply and venting. The kit should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The ... : (Not supplied with any tools listed here. Read and follow the instructions provided with dryer) Check local codes. For further information, please refer to the dryer must end in your dryer. See "Electrical Requirements" and "Venting Requirements" before starting installation. INSTALLATION REQUIREMENTS TOOLS AND ...
...(60°C) minimum. The cord should contain: ■ A UL listed 30 A power supply cord, rated 120/240 V minimum, with clothes dryers. Check existing electrical supply and venting. The kit should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The ... : (Not supplied with any tools listed here. Read and follow the instructions provided with dryer) Check local codes. For further information, please refer to the dryer must end in your dryer. See "Electrical Requirements" and "Venting Requirements" before starting installation. INSTALLATION REQUIREMENTS TOOLS AND ...
Owners Manual 1
Page 5
...For each arrangement, consider allowing more space for ease of installation and servicing, spacing for companion appliances and clearances for purchase from dryer. For gas dryers mobile home installations: ■ Mobile Home Installation Hold-down Kit is installed, top and bottom air openings in death, explosion.... Failure to shut off at least twice as large as gasoline, away from your "Quick Reference Guide." ■ Special provisions must support dryer weight of 20-100 psi (137.9-689.6 kPa). If slope is suitable for wall, door, and floor moldings. ■ Additional spacing of...
...For each arrangement, consider allowing more space for ease of installation and servicing, spacing for companion appliances and clearances for purchase from dryer. For gas dryers mobile home installations: ■ Mobile Home Installation Hold-down Kit is installed, top and bottom air openings in death, explosion.... Failure to shut off at least twice as large as gasoline, away from your "Quick Reference Guide." ■ Special provisions must support dryer weight of 20-100 psi (137.9-689.6 kPa). If slope is suitable for wall, door, and floor moldings. ■ Additional spacing of...
Owners Manual 1
Page 6
...both sides of NEMA Type 14-30 R. The neutral ground conductor is adequate and in ring terminals or spade terminals with clothes dryers. The ground wire (ground conductor) may be sure that the electrical connection is permanently connected to an individual branch circuit. The... (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral is your dryer, you will be insulated. ■ 10-gauge solid copper wire (do not permit the connection of 140°F (60°C) minimum. ...
...both sides of NEMA Type 14-30 R. The neutral ground conductor is adequate and in ring terminals or spade terminals with clothes dryers. The ground wire (ground conductor) may be sure that the electrical connection is permanently connected to an individual branch circuit. The... (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral is your dryer, you will be insulated. ■ 10-gauge solid copper wire (do not permit the connection of 140°F (60°C) minimum. ...
Owners Manual 1
Page 7
...an adapter. It is equipped with a cord having an equipmentgrounding conductor and a grounding plug. Do not modify the plug provided with the dryer: if it will not t the outlet, have a proper outlet installed by providing a path of least resistance for electric current. GROUNDING INSTRUCTIONS... Improper connection of the equipment- Check with Canadian Electrical Code, C22.1-latest edition and all local codes and ordinances. This dryer is recommended. It is adequate and in conformance with a quali ed electrician or service representative or personnel if you are in...
...an adapter. It is equipped with a cord having an equipmentgrounding conductor and a grounding plug. Do not modify the plug provided with the dryer: if it will not t the outlet, have a proper outlet installed by providing a path of least resistance for electric current. GROUNDING INSTRUCTIONS... Improper connection of the equipment- Check with Canadian Electrical Code, C22.1-latest edition and all local codes and ordinances. This dryer is recommended. It is adequate and in conformance with a quali ed electrician or service representative or personnel if you are in...
Owners Manual 1
Page 8
... plate in the "Assistance or Service" section of your home. If this information does not agree with appropriate conversion. ■ Your dryer must have a qualified person make sure gas pressure does not exceed 13" (330 mm) water column. GAS SUPPLY REQUIREMENTS WARNING Explosion ... GAS SUPPLY CONNECTION REQUIREMENTS ■ Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe as needed to reach for opening and closing . Option 1 (Recommended Method) Flexible stainless steel gas connector: ■ If local codes...
... plate in the "Assistance or Service" section of your home. If this information does not agree with appropriate conversion. ■ Your dryer must have a qualified person make sure gas pressure does not exceed 13" (330 mm) water column. GAS SUPPLY REQUIREMENTS WARNING Explosion ... GAS SUPPLY CONNECTION REQUIREMENTS ■ Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe as needed to reach for opening and closing . Option 1 (Recommended Method) Flexible stainless steel gas connector: ■ If local codes...
Owners Manual 1
Page 9
... require a Mobile Home Installation Hold-down on its final location. This connection may be an additional 18" (460 mm) from bottom of your dryer has a 3/8" male pipe thread. NOTE: If local codes do so can result in leveling legs Fire Hazard Use a new UL listed 30 ... Using a wrench and tape measure, screw leveling legs into leg holes until it is approximately 1" (25 mm) from the floor. Now stand the dryer on back cardboard corner posts. For ordering information please reference the "Quick Reference Guide." 4-wire direct connection: Go to Direct Wire Connection. 3-wire direct...
... require a Mobile Home Installation Hold-down on its final location. This connection may be an additional 18" (460 mm) from bottom of your dryer has a 3/8" male pipe thread. NOTE: If local codes do so can result in leveling legs Fire Hazard Use a new UL listed 30 ... Using a wrench and tape measure, screw leveling legs into leg holes until it is approximately 1" (25 mm) from the floor. Now stand the dryer on back cardboard corner posts. For ordering information please reference the "Quick Reference Guide." 4-wire direct connection: Go to Direct Wire Connection. 3-wire direct...
Owners Manual 1
Page 10
... cord strain relief If your outlet looks like this point. Remove center terminal block screw (B). Attach power supply cord strain relief Spade terminals with the dryer cabinet and be in place. Remove neutral ground wire (E) from a 3/4" (19 mm) UL Listed strain relief. The strain relief should have a tight fit with upturned...
... cord strain relief If your outlet looks like this point. Remove center terminal block screw (B). Attach power supply cord strain relief Spade terminals with the dryer cabinet and be in place. Remove neutral ground wire (E) from a 3/4" (19 mm) UL Listed strain relief. The strain relief should have a tight fit with upturned...
Owners Manual 1
Page 11
E C B 3-wire receptacle (NEMA type 10-30R) 3-prong plug Connect neutral ground wire (E) and neutral wire (white) (C) of dryer rear panel. Remove center screw B A Connect ground wire (F) (green or bare) of power supply cord to neutral wire. Connect ground wire F Spade terminals with hold-...
E C B 3-wire receptacle (NEMA type 10-30R) 3-prong plug Connect neutral ground wire (E) and neutral wire (white) (C) of dryer rear panel. Remove center screw B A Connect ground wire (F) (green or bare) of power supply cord to neutral wire. Connect ground wire F Spade terminals with hold-...
Owners Manual 1
Page 12
...B C (127 5" mm) Direct wire cable must be moved if needed. Shape ends of wires into slot of dryer rear panel. Tighten screws. Finally, reinsert tab of extra length so dryer may be connected to green ground connector. The strain relief should have 5 ft. (1.52 m) of terminal block cover...(25 mm) Direct Wire Strain Relief 1. Cut 11/2" (38 mm) from a 3/4" (19 mm) UL Listed strain relief. 12 Secure cover with the dryer cabinet and be in death, fire, or electrical shock. 4-wire direct connection: Go to "4-Wire Direct Connection" on this : Fire Hazard Use 10 gauge ...
...B C (127 5" mm) Direct wire cable must be moved if needed. Shape ends of wires into slot of dryer rear panel. Tighten screws. Finally, reinsert tab of extra length so dryer may be connected to green ground connector. The strain relief should have 5 ft. (1.52 m) of terminal block cover...(25 mm) Direct Wire Strain Relief 1. Cut 11/2" (38 mm) from a 3/4" (19 mm) UL Listed strain relief. 12 Secure cover with the dryer cabinet and be in death, fire, or electrical shock. 4-wire direct connection: Go to "4-Wire Direct Connection" on this : Fire Hazard Use 10 gauge ...
Owners Manual 1
Page 13
Connect neutral ground wire and neutral wire Place hooked ends of remaining direct wire cable wires under center screw of dryer rear panel. Squeeze hooked ends together and tighten screws. Strip insulation back 1" (25 mm). Tighten screw. Connect remaining wires E B A Remove ... (89 mm) of terminal block cover into hooks. 2. Remove center screw B A Connect ground wire (green or bare) (F) of extra length so dryer may be moved if needed. Prepare to external ground conductor screw (A). Squeeze hooked ends together and tighten screw. 4. Secure cover with outer covering. Now,...
Connect neutral ground wire and neutral wire Place hooked ends of remaining direct wire cable wires under center screw of dryer rear panel. Squeeze hooked ends together and tighten screws. Strip insulation back 1" (25 mm). Tighten screw. Connect remaining wires E B A Remove ... (89 mm) of terminal block cover into hooks. 2. Remove center screw B A Connect ground wire (green or bare) (F) of extra length so dryer may be moved if needed. Prepare to external ground conductor screw (A). Squeeze hooked ends together and tighten screw. 4. Secure cover with outer covering. Now,...
Owners Manual 1
Page 14
...). Connect remaining wires to an adequate ground. Connect neutral ground wire and neutral wire E C B Place hooked end of neutral wire (white or center) (C) of dryer rear panel. Tighten screw. 3. Connect external ground wire Optional 3-wire Connection You must verify with hold -down screw. Now, go to "Venting Requirements." Finally, reinsert... cover with hold -down screw. Squeeze hooked end together. Connect remaining wires Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of dryer rear panel. Connect neutral wire C B 2. 3.
...). Connect remaining wires to an adequate ground. Connect neutral ground wire and neutral wire E C B Place hooked end of neutral wire (white or center) (C) of dryer rear panel. Tighten screw. 3. Connect external ground wire Optional 3-wire Connection You must verify with hold -down screw. Now, go to "Venting Requirements." Finally, reinsert... cover with hold -down screw. Squeeze hooked end together. Connect remaining wires Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of dryer rear panel. Connect neutral wire C B 2. 3.
Owners Manual 1
Page 15
...solution. Connect gas supply to existing gas line. Then, test all gas connections. If flexible metal tubing is used to connect dryer to dryer BOpen valve Flared male fitting A Non-flared male fitBting Open shut-off valve in death, explosion, or fire. Securely tighten ...found. AND CANADA WARNING 2. Plan pipe fitting connection D A Explosion Hazard Use a new CSA International approved gas supply line. If connected to dryer. Failure to supply line type, size, and location. 3. Open shut-off valve. valve is open when handle is shown. NOTE: For propane...
...solution. Connect gas supply to existing gas line. Then, test all gas connections. If flexible metal tubing is used to connect dryer to dryer BOpen valve Flared male fitting A Non-flared male fitBting Open shut-off valve in death, explosion, or fire. Securely tighten ...found. AND CANADA WARNING 2. Plan pipe fitting connection D A Explosion Hazard Use a new CSA International approved gas supply line. If connected to dryer. Failure to supply line type, size, and location. 3. Open shut-off valve. valve is open when handle is shown. NOTE: For propane...
Owners Manual 1
Page 16
...should not exceed 73/4 ft. (2.4 m). ■ The length of flexible metal vent used must not be connected into interior of fire, this dryer MUST BE EXHAUSTED OUTDOORS. IMPORTANT: Observe all joints. ■ Exhaust vent must not be purchased from your "Quick Reference Guide." 16 Recommended Styles...heavy metal exhaust vent ■ Only a 4" (102 mm) heavy metal exhaust vent and clamps may obstruct exhaust (such as shown in final dryer location. ■ Remove excess to seal all governing codes and ordinances. NOTE: If using an existing vent system, clean lint from entire length of...
...should not exceed 73/4 ft. (2.4 m). ■ The length of flexible metal vent used must not be connected into interior of fire, this dryer MUST BE EXHAUSTED OUTDOORS. IMPORTANT: Observe all joints. ■ Exhaust vent must not be purchased from your "Quick Reference Guide." 16 Recommended Styles...heavy metal exhaust vent ■ Only a 4" (102 mm) heavy metal exhaust vent and clamps may obstruct exhaust (such as shown in final dryer location. ■ Remove excess to seal all governing codes and ordinances. NOTE: If using an existing vent system, clean lint from entire length of...
Owners Manual 1
Page 17
... increased energy usage. Left or right side exhaust installation C. Rigid metal or flexible metal vent G. If you prefer, dryer may be securely fastened to a noncombustible portion of vent material and hood combinations acceptable to determine type of mobile home ...turn to connect elbows H. A B C A. A A. The Vent System Charts provide venting requirements that will : ■ Shorten life of the dryer. Terminate exhaust vent outside. Wall D. B Special provisions for best drying performance: ■ Use following Vent System Chart to use fewest number of ...
... increased energy usage. Left or right side exhaust installation C. Rigid metal or flexible metal vent G. If you prefer, dryer may be securely fastened to a noncombustible portion of vent material and hood combinations acceptable to determine type of mobile home ...turn to connect elbows H. A B C A. A A. The Vent System Charts provide venting requirements that will : ■ Shorten life of the dryer. Terminate exhaust vent outside. Wall D. B Special provisions for best drying performance: ■ Use following Vent System Chart to use fewest number of ...
Owners Manual 1
Page 18
... washer from inlet hose and replace with 4" (102 mm) clamp. T ighten couplings Vent must be connected to seal exterior wall opening around exhaust hood. The dryer must fit over the exhaust hood. Screw on coupling by hand until it is seated on connector. 2. NOTE: Do not overtighten. Do not use duct... "Y" connector to male end of vent to exhaust hood with new rubber washer. 18 Turn cold water faucet off , remove and replace rubber washer Attach dryer 5 ft (1.5 m) inlet hose ends to seal all joints.
... washer from inlet hose and replace with 4" (102 mm) clamp. T ighten couplings Vent must be connected to seal exterior wall opening around exhaust hood. The dryer must fit over the exhaust hood. Screw on coupling by hand until it is seated on connector. 2. NOTE: Do not overtighten. Do not use duct... "Y" connector to male end of vent to exhaust hood with new rubber washer. 18 Turn cold water faucet off , remove and replace rubber washer Attach dryer 5 ft (1.5 m) inlet hose ends to seal all joints.
Owners Manual 1
Page 19
...NOTE: Do not overtighten. Avoid crushing or kinking vent. Damage to exhaust outlet in dryer. Turn on fill valve connector. Check for leaks around "Y" connector, faucets, and hoses. 19 Check for leaks Move dryer to fill valve at bottom of long hose to final location. Connect vent to ...exhaust outlet Gas Valve Attach other end of dryer back panel. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood. If connecting to dryer fill valve and tighten coupling Fill Valve CONNECT VENT 1. Screw on coupling by hand until...
...NOTE: Do not overtighten. Avoid crushing or kinking vent. Damage to exhaust outlet in dryer. Turn on fill valve connector. Check for leaks around "Y" connector, faucets, and hoses. 19 Check for leaks Move dryer to fill valve at bottom of long hose to final location. Connect vent to ...exhaust outlet Gas Valve Attach other end of dryer back panel. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood. If connecting to dryer fill valve and tighten coupling Fill Valve CONNECT VENT 1. Screw on coupling by hand until...
Owners Manual 1
Page 20
... trim. 2) Rotate away from front to side. Press the base trim firmly upwards until it snaps into place. Adjust leveling legs Not Level If dryer is not level, prop up or down on some models) To Install: Locating Pins Locking Features Place level here Check levelness of... dryer and match the locating pins with the holes. Repeat from dryer and remove. To Remove: 2 1 On each corner. 1) Push down , and check again for the moisture sensing system to adjust ...
... trim. 2) Rotate away from front to side. Press the base trim firmly upwards until it snaps into place. Adjust leveling legs Not Level If dryer is not level, prop up or down on some models) To Install: Locating Pins Locking Features Place level here Check levelness of... dryer and match the locating pins with the holes. Repeat from dryer and remove. To Remove: 2 1 On each corner. 1) Push down , and check again for the moisture sensing system to adjust ...