Installation Instructions
Page 1
U.S.A. W10252706B U.S.A. Only 4 INSTALLATION INSTRUCTIONS 6 Unpack Range 6 Install Anti-Tip Bracket 6 Electrical Connection - INSTALLATION INSTRUCTIONS 30" (76 CM) FREESTANDING ELECTRIC RANGES Table of Contents RANGE SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 3 Electrical Requirements - Only 7 Verify Anti-Tip Bracket Location 12 Level Range 12 Storage Drawer 12 Complete Installation 13 Moving the Range 14 ANTI-TIP BRACKET TEMPLATE 15 IMPORTANT: Save for local electrical inspector's use.
U.S.A. W10252706B U.S.A. Only 4 INSTALLATION INSTRUCTIONS 6 Unpack Range 6 Install Anti-Tip Bracket 6 Electrical Connection - INSTALLATION INSTRUCTIONS 30" (76 CM) FREESTANDING ELECTRIC RANGES Table of Contents RANGE SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 3 Electrical Requirements - Only 7 Verify Anti-Tip Bracket Location 12 Level Range 12 Storage Drawer 12 Complete Installation 13 Moving the Range 14 ANTI-TIP BRACKET TEMPLATE 15 IMPORTANT: Save for local electrical inspector's use.
Installation Instructions
Page 3
...; ¼" nut driver and nut driver 3.2 mm) drill bit (for wood floors) 4.8 mm) carbide-tipped masonry drill bit (for concrete/ceramic floors) ■ Tin snips or large wire cutters (for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening dimensions that projects...anti-tip bracket must be securely mounted to be made by a licensed, qualified electrical installer. To install the antitip bracket shipped with the range, see "Install Anti-Tip Bracket" section. ■ Grounded electrical supply is not applicable, use the Standard for use in a mobile home ...
...; ¼" nut driver and nut driver 3.2 mm) drill bit (for wood floors) 4.8 mm) carbide-tipped masonry drill bit (for concrete/ceramic floors) ■ Tin snips or large wire cutters (for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening dimensions that projects...anti-tip bracket must be securely mounted to be made by a licensed, qualified electrical installer. To install the antitip bracket shipped with the range, see "Install Anti-Tip Bracket" section. ■ Grounded electrical supply is not applicable, use the Standard for use in a mobile home ...
Installation Instructions
Page 4
...way in conformance with leveling legs screwed all local codes and ordinances. opening width C. Outlet - 8" (20.3 cm) to top of electric shock. from : National Fire Protection Association One Batterymarch Park Quincy, MA 02269. Be sure that the ground path and wire gauge are ... determine that the electrical connection and wire size are in doubt as to combustible walls with local codes. Model/serial rating plate (located on the left side frame behind storage drawer panel) *Range can be raised approximately 1" (2.5 cm) by a qualified electrician. 4 opening width E. required ...
...way in conformance with leveling legs screwed all local codes and ordinances. opening width C. Outlet - 8" (20.3 cm) to top of electric shock. from : National Fire Protection Association One Batterymarch Park Quincy, MA 02269. Be sure that the ground path and wire gauge are ... determine that the electrical connection and wire size are in doubt as to combustible walls with local codes. Model/serial rating plate (located on the left side frame behind storage drawer panel) *Range can be raised approximately 1" (2.5 cm) by a qualified electrician. 4 opening width E. required ...
Installation Instructions
Page 5
...and connections must conform with upturned ends, terminating in the "Product Dimensions" section of the "Location Requirements" section. ■ This range is used . See "Electrical Connection." The fourth (grounding) conductor must be at the point the power supply cord enters the appliance. Cord should be Type SRD ...load listed on the model/serial rating plate. **If connecting to a 50-amp circuit, use kits that the range can be connected to the proper electrical voltage and frequency as specified on the supply end. If local codes do not permit ground through the neutral conductor...
...and connections must conform with upturned ends, terminating in the "Product Dimensions" section of the "Location Requirements" section. ■ This range is used . See "Electrical Connection." The fourth (grounding) conductor must be at the point the power supply cord enters the appliance. Cord should be Type SRD ...load listed on the model/serial rating plate. **If connecting to a 50-amp circuit, use kits that the range can be connected to the proper electrical voltage and frequency as specified on the supply end. If local codes do not permit ground through the neutral conductor...
Installation Instructions
Page 7
... tag holding three 10-32 hex nuts from range. 3. To mount anti-tip bracket to drill 2 holes at the positions marked on the bracket template. Remove template from floor. Electrical Connection - Electrical Shock Hazard Disconnect power before servicing. To mount anti-tip bracket to concrete or ceramic floor, use a 4.8 mm) masonry drill bit to...
... tag holding three 10-32 hex nuts from range. 3. To mount anti-tip bracket to drill 2 holes at the positions marked on the bracket template. Remove template from floor. Electrical Connection - Electrical Shock Hazard Disconnect power before servicing. To mount anti-tip bracket to concrete or ceramic floor, use a 4.8 mm) masonry drill bit to...
Installation Instructions
Page 8
...Electrical Connection Options If your type of the range. Concuit ■ Tighten strain relief screw against the power supply cord. 4-wire direct ³⁄₈" (1.0 cm) A circuit breaker 4-wire connection: box or fused Direct wire disconnect 5" (12.7 cm) 3-wire receptacle (NEMA type 10-50R) A UL listed, 250-volt minimum, 40-amp, range...the end of metal ground strap must be Go to Section: connecting to remove the ground-link screw from the back of electrical connection: 4-wire (recommended) 3-wire (if 4-wire is not available) A. 4. Add strain relief. UL listed strain ...
...Electrical Connection Options If your type of the range. Concuit ■ Tighten strain relief screw against the power supply cord. 4-wire direct ³⁄₈" (1.0 cm) A circuit breaker 4-wire connection: box or fused Direct wire disconnect 5" (12.7 cm) 3-wire receptacle (NEMA type 10-50R) A UL listed, 250-volt minimum, 40-amp, range...the end of metal ground strap must be Go to Section: connecting to remove the ground-link screw from the back of electrical connection: 4-wire (recommended) 3-wire (if 4-wire is not available) A. 4. Add strain relief. UL listed strain ...
Installation Instructions
Page 10
... connect the bare (green) ground wire to line 1 (black), neutral (white), and line 2 (red) wires. Depending on your type of electrical supply (4-wire or 3-wire connection). 4-wire Connection: Direct Wire Use this method for: ■ New branch-circuit installations (1996 NEC) ■...lugs to the range with the ground-link screw and ground-link section. Metal ground strap B. Setscrew C. Line 2 (red) wire D. Neutral (white) wire E. Strip outer covering back 3" (7.6 cm) to the terminal block. A A B B C A. The ground wire must be connected directly to your electrical supply, make ...
... connect the bare (green) ground wire to line 1 (black), neutral (white), and line 2 (red) wires. Depending on your type of electrical supply (4-wire or 3-wire connection). 4-wire Connection: Direct Wire Use this method for: ■ New branch-circuit installations (1996 NEC) ■...lugs to the range with the ground-link screw and ground-link section. Metal ground strap B. Setscrew C. Line 2 (red) wire D. Neutral (white) wire E. Strip outer covering back 3" (7.6 cm) to the terminal block. A A B B C A. The ground wire must be connected directly to your electrical supply, make ...
Installation Instructions
Page 13
... its fully forward position. 2. See the Use and Care Guide for heat. Slowly push the storage drawer into the closed position. 5. See "Level Range." 5. Plug power cord into an outlet. ■ Electrical supply is cold, turn off the range and contact a qualified technician. 13 Turn on . 8. or circuit breaker has not tripped. ■...
... its fully forward position. 2. See the Use and Care Guide for heat. Slowly push the storage drawer into the closed position. 5. See "Level Range." 5. Plug power cord into an outlet. ■ Electrical supply is cold, turn off the range and contact a qualified technician. 13 Turn on . 8. or circuit breaker has not tripped. ■...
Installation Instructions
Page 14
... the anti-tip bracket securely attached to floor. ■ Slide range back so rear range foot is level. 14 Replace all parts and panels before servicing. Check that range is under anti-tip bracket. 5. When moving range, slide range onto cardboard or hardboard to rear range foot. Electrical Shock Hazard Disconnect power before operating. WARNING Moving the...
... the anti-tip bracket securely attached to floor. ■ Slide range back so rear range foot is level. 14 Replace all parts and panels before servicing. Check that range is under anti-tip bracket. 5. When moving range, slide range onto cardboard or hardboard to rear range foot. Electrical Shock Hazard Disconnect power before operating. WARNING Moving the...
Owners Manual
Page 1
...covered in TROUBLESHOOTING, please visit our website at 1-800-688-9900. You will need assistance, call us at www.maytag.com for purchasing this high-quality product. If you still need your model and serial number located on the oven frame... Foil 6 Positioning Racks and Bakeware 6 Oven Vent 7 Baking and Roasting 7 Broiling 7 Convection Baking and Roasting 7 Timed Cooking 8 RANGE CARE 8 Self-Cleaning Cycle 8 General Cleaning 9 Oven Light 9 TROUBLESHOOTING 10 ACCESSORIES 11 WARRANTY 11 W10234645A ELECTRIC RANGE USER INSTRUCTIONS THANK YOU for additional information.
...covered in TROUBLESHOOTING, please visit our website at 1-800-688-9900. You will need assistance, call us at www.maytag.com for purchasing this high-quality product. If you still need your model and serial number located on the oven frame... Foil 6 Positioning Racks and Bakeware 6 Oven Vent 7 Baking and Roasting 7 Broiling 7 Convection Baking and Roasting 7 Timed Cooking 8 RANGE CARE 8 Self-Cleaning Cycle 8 General Cleaning 9 Oven Light 9 TROUBLESHOOTING 10 ACCESSORIES 11 WARRANTY 11 W10234645A ELECTRIC RANGE USER INSTRUCTIONS THANK YOU for additional information.
Owners Manual
Page 3
... time to cause burns - Boilover causes smoking and greasy spillovers that it is in color. Only certain types of glass, glass/ceramic, ceramic, earthenware, or other servicing should never be careful to avoid steam burn. Some cleaners can produce noxious fumes if applied to cover...these openings, oven doors, and windows of oven doors. IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electrical shock, injury to persons, or damage when using the range. ■ User Servicing - Areas near surface units. ■ Do Not Use Water on any kind should break...
... time to cause burns - Boilover causes smoking and greasy spillovers that it is in color. Only certain types of glass, glass/ceramic, ceramic, earthenware, or other servicing should never be careful to avoid steam burn. Some cleaners can produce noxious fumes if applied to cover...these openings, oven doors, and windows of oven doors. IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electrical shock, injury to persons, or damage when using the range. ■ User Servicing - Areas near surface units. ■ Do Not Use Water on any kind should break...
Owners Manual
Page 11
... Scraper (ceramic glass models) Order Part Number WA906B Stainless Steel Cleaner and Polish (stainless steel models) Order Part Number 31462 All-Purpose Appliance Cleaner Order Part Number 31682 Split-Rack with Removable Insert Order Part Number 4396927 Broiler Pan Order Part Number 4396923 MAYTAG® ...shall be easily determined. Outside the 50 United States and Canada, this warranty. 8. This warranty is not installed in accordance with electrical or plumbing codes, or use or when it is used in the country in which it is installed in accordance with published installation ...
... Scraper (ceramic glass models) Order Part Number WA906B Stainless Steel Cleaner and Polish (stainless steel models) Order Part Number 31462 All-Purpose Appliance Cleaner Order Part Number 31682 Split-Rack with Removable Insert Order Part Number 4396927 Broiler Pan Order Part Number 4396923 MAYTAG® ...shall be easily determined. Outside the 50 United States and Canada, this warranty. 8. This warranty is not installed in accordance with electrical or plumbing codes, or use or when it is used in the country in which it is installed in accordance with published installation ...
Dimension Guide
Page 1
... the cabinet. For complete details, see NOTE*. Specifications subject to change without notice. Ref. 30" (76 cm) Freestanding Electric Range PRODUCT MODEL NUMBERS MER5605W MER7661W MER7662W MER7765W MER7775W Electrical: Range must be connected to the proper electrical voltage and frequency as specified on the left side frame behind the storage drawer panel. Model/serial rating...
... the cabinet. For complete details, see NOTE*. Specifications subject to change without notice. Ref. 30" (76 cm) Freestanding Electric Range PRODUCT MODEL NUMBERS MER5605W MER7661W MER7662W MER7765W MER7775W Electrical: Range must be connected to the proper electrical voltage and frequency as specified on the left side frame behind the storage drawer panel. Model/serial rating...
Warranty Information
Page 1
... not cover: 1. Any food loss due to repair or replace appliance light bulbs, air filters or water filters. Major appliances with electrical or plumbing codes, or use your major appliance is located in the United States or Canada and applies only when the major appliance ... Cooktop Scraper (ceramic glass models) Order Part Number WA906B Stainless Steel Cleaner and Polish (stainless steel models) Order Part Number 31462 All-Purpose Appliance Cleaner Order Part Number 31682 Split-Rack with Removable Insert Order Part Number 4396927 Broiler Pan Order Part Number 4396923 MAYTAG® MAJOR...
... not cover: 1. Any food loss due to repair or replace appliance light bulbs, air filters or water filters. Major appliances with electrical or plumbing codes, or use your major appliance is located in the United States or Canada and applies only when the major appliance ... Cooktop Scraper (ceramic glass models) Order Part Number WA906B Stainless Steel Cleaner and Polish (stainless steel models) Order Part Number 31462 All-Purpose Appliance Cleaner Order Part Number 31682 Split-Rack with Removable Insert Order Part Number 4396927 Broiler Pan Order Part Number 4396923 MAYTAG® MAJOR...