INTENDED FOR PROFESSIONAL INSTALLATION ONLY. The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com SL3000UL™ VEHICULAR SLIDE GATE OPERATOR OWNER'S MANUAL THE SL3000UL™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES.
INTENDED FOR PROFESSIONAL INSTALLATION ONLY. The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com SL3000UL™ VEHICULAR SLIDE GATE OPERATOR OWNER'S MANUAL THE SL3000UL™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES.
Owners Manual
Page 3
... 3 Safety Installation Information 4 Gate Construction Information 5 Safety Precautions 6 Suggested Safety Protection Device Locations 7-8 INSTALLATION When you see this manual and follow all safety instructions. • DO NOT attempt repair or service of your gate and/or the gate operator if you...29 Adjusting Reversing Sensor(s 30 MAINTENANCE AND OPERATION Maintenance 31 OPERATION Built-In Reset Switch 32 Audio Alarm 32 EMERGENCY MANUAL RELEASE 33 ACCESSORIES 34 WIRING DIAGRAMS 35-42 TROUBLESHOOTING 43-44 REPAIR PARTS Repair Part Illustrations 45 How to Order ...
... 3 Safety Installation Information 4 Gate Construction Information 5 Safety Precautions 6 Suggested Safety Protection Device Locations 7-8 INSTALLATION When you see this manual and follow all safety instructions. • DO NOT attempt repair or service of your gate and/or the gate operator if you...29 Adjusting Reversing Sensor(s 30 MAINTENANCE AND OPERATION Maintenance 31 OPERATION Built-In Reset Switch 32 Audio Alarm 32 EMERGENCY MANUAL RELEASE 33 ACCESSORIES 34 WIRING DIAGRAMS 35-42 TROUBLESHOOTING 43-44 REPAIR PARTS Repair Part Illustrations 45 How to Order ...
Owners Manual
Page 6
... edge of travel of the gate operator. 8. Outdoor or easily accessible controls shall have a security feature to the installation of the vehicular gate. 6. Reference owner's manual regarding placement of non-contact sensor for the construction and the usage class of entrapment. c. One or more contact sensors shall be located at the...
... edge of travel of the gate operator. 8. Outdoor or easily accessible controls shall have a security feature to the installation of the vehicular gate. 6. Reference owner's manual regarding placement of non-contact sensor for the construction and the usage class of entrapment. c. One or more contact sensors shall be located at the...
Owners Manual
Page 7
... Class IV vehicular horizontal slide gates: 3.2.1 All weight bearing exposed rollers 8 feet (2.44 m), or less, above grade. 1.5 An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator. 1.6 A gate latch shall not be installed on an automatically operated gate. 1.7 Protrusions shall not be permitted on...
... Class IV vehicular horizontal slide gates: 3.2.1 All weight bearing exposed rollers 8 feet (2.44 m), or less, above grade. 1.5 An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator. 1.6 A gate latch shall not be installed on an automatically operated gate. 1.7 Protrusions shall not be permitted on...
Owners Manual
Page 21
...Make sure the "System ON" and "Charge OK" LEDs are lit. Socket Reset button and interlock wires, Do Not Remove. 120Vac Power Failure Manual Mode Push and Hold to 12 Volt 1 2 3 315 MHz 12 VDC 4 See Accessories 19 Normal operation will be dedicated to operate in ...On, OmniControl™ Board Malfunction Turn the 120Vac power off then gate opens automatically. FACTORY INSTALLED DC2000™ CONNECTION DC2000™ Startup Plug in "manual mode" until 120Vac power is set the same as "One-Button", "Three Push Button", "Key Switch", "Photoelectric Sensor" or "Edge Sensor" ...
...Make sure the "System ON" and "Charge OK" LEDs are lit. Socket Reset button and interlock wires, Do Not Remove. 120Vac Power Failure Manual Mode Push and Hold to 12 Volt 1 2 3 315 MHz 12 VDC 4 See Accessories 19 Normal operation will be dedicated to operate in ...On, OmniControl™ Board Malfunction Turn the 120Vac power off then gate opens automatically. FACTORY INSTALLED DC2000™ CONNECTION DC2000™ Startup Plug in "manual mode" until 120Vac power is set the same as "One-Button", "Three Push Button", "Key Switch", "Photoelectric Sensor" or "Edge Sensor" ...
Owners Manual
Page 22
.... Turn key again and HOLD to Open. DC2000™ DEVICE WIRING Manually Operated DC2000™ Devices Manual external devices should be dry-contact which do not consume any reason. Manual One-Button 1234567 See Accessories 1234567 Reset button and interlock wires, Do Not... 1234567 Ground Failsafe Photoelectric Sensor: If a photoelectric sensor is not working, loses power or photoelectric sensor is for property owner's emergency access ONLY. Manual 3-Button N.O. 3 N.O. 2 N.O. 1 Com 4 4 Com Com 4 Push and HOLD a button to maintain gate safety when the DC2000™...
.... Turn key again and HOLD to Open. DC2000™ DEVICE WIRING Manually Operated DC2000™ Devices Manual external devices should be dry-contact which do not consume any reason. Manual One-Button 1234567 See Accessories 1234567 Reset button and interlock wires, Do Not... 1234567 Ground Failsafe Photoelectric Sensor: If a photoelectric sensor is not working, loses power or photoelectric sensor is for property owner's emergency access ONLY. Manual 3-Button N.O. 3 N.O. 2 N.O. 1 Com 4 4 Com Com 4 Push and HOLD a button to maintain gate safety when the DC2000™...
Owners Manual
Page 23
... NOTE: Refer to operator before installing plug-in loop detectors. 21 Plug-In "Safety" Loop Detector - Example of a 3 wire turn loop connected in loop detector manual for information about plug-in loop detectors. Example of a inside and outside 2 wire turn loop. (See "Installing Insulated Loop Wire" on next page for exiting...
... NOTE: Refer to operator before installing plug-in loop detectors. 21 Plug-In "Safety" Loop Detector - Example of a 3 wire turn loop connected in loop detector manual for information about plug-in loop detectors. Example of a inside and outside 2 wire turn loop. (See "Installing Insulated Loop Wire" on next page for exiting...
Owners Manual
Page 27
...W4 Quick Close Circuit Allows the gate's close cycle to close quicker than the OmniControl™ timer will allow. Refer to the QCC manual for more specific information. Ground Comm N.C. CENTER SAFETY EXIT SENSOR ALARM W4 G B A MS LINK ALARM SENSOR DC-BACKUP SYSTEM ON... OFF OPEN LEFT 1 3 ON OPEN RIGHT COMMAND PROCESSED FIRE DEPT. OMNI OPTION BOARD CONNECTIONS NOTE: Refer to the Omni Option Board manual for more specific information. See Accessories. N.O. N.C. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE ...
...W4 Quick Close Circuit Allows the gate's close cycle to close quicker than the OmniControl™ timer will allow. Refer to the QCC manual for more specific information. Ground Comm N.C. CENTER SAFETY EXIT SENSOR ALARM W4 G B A MS LINK ALARM SENSOR DC-BACKUP SYSTEM ON... OFF OPEN LEFT 1 3 ON OPEN RIGHT COMMAND PROCESSED FIRE DEPT. OMNI OPTION BOARD CONNECTIONS NOTE: Refer to the Omni Option Board manual for more specific information. See Accessories. N.O. N.C. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE ...
Owners Manual
Page 33
.... KEEP GATES PROPERLY MAINTAINED. ALL maintenance MUST be kept clean to the operator it monthly (Page 30). 6. Test the gate operator monthly. Read the owner's manual. Disconnect power before servicing. 2.
.... KEEP GATES PROPERLY MAINTAINED. ALL maintenance MUST be kept clean to the operator it monthly (Page 30). 6. Test the gate operator monthly. Read the owner's manual. Disconnect power before servicing. 2.
Owners Manual
Page 35
... to disconnect power to release the chain. Turn the power OFF! Allen wrench drill bit size is held in hole. The chain is 5/16" OPTIONAL MANUAL RELEASE Pull firmly on the "T" Handle to the operator. Serve 2 Air (2) Conditioner Eug. Turn the crank to open the gate. Push the crank tool in...
... to disconnect power to release the chain. Turn the power OFF! Allen wrench drill bit size is held in hole. The chain is 5/16" OPTIONAL MANUAL RELEASE Pull firmly on the "T" Handle to the operator. Serve 2 Air (2) Conditioner Eug. Turn the crank to open the gate. Push the crank tool in...
Owners Manual
Page 44
... Com Red N.O. Interlock Assembly Black Com Red N.O. 5 One Button 4 One Button 5 Key Switch 4 Key Switch Manual Key Switch Dry Contact 4 Black 3 Red Reset Switch 12Vdc Photoelectric Sensor Manual One Button Dry Contact J # J Pin # J20 1 J20 2 J20 3 J20 4 J20 5 J20 6...dedicated to J6 Pin 3,4 OmniControl™ Board (Sensor) 1 2 3 4 5 6 7 J20 1 Open N.O. 2 Close N.O. 3 Stop N.O. Close N.O. Manual Three Button Dry Contact 6 + 12Vdc 5 Radio Relay 4 - Radio Relay Reset Switch/Interlock Assembly One Button Key Switch Radio Relay Radio + 12Vdc Photoelectric Sensor +...
... Com Red N.O. Interlock Assembly Black Com Red N.O. 5 One Button 4 One Button 5 Key Switch 4 Key Switch Manual Key Switch Dry Contact 4 Black 3 Red Reset Switch 12Vdc Photoelectric Sensor Manual One Button Dry Contact J # J Pin # J20 1 J20 2 J20 3 J20 4 J20 5 J20 6...dedicated to J6 Pin 3,4 OmniControl™ Board (Sensor) 1 2 3 4 5 6 7 J20 1 Open N.O. 2 Close N.O. 3 Stop N.O. Close N.O. Manual Three Button Dry Contact 6 + 12Vdc 5 Radio Relay 4 - Radio Relay Reset Switch/Interlock Assembly One Button Key Switch Radio Relay Radio + 12Vdc Photoelectric Sensor +...
Owners Manual
Page 48
HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA. Manual Crank not Included Power Back-Up Unit - Drive Belt DC SL (DM) - Bushing, 7/8" OD, .120" Wall x 1.950" - Limit Switch Bearing Holder - Electronic Metal Box - ... Assembly K75-50893 - Omni Motor Harness DM 312HM - Pulley DC2000 1/2 ID Idler Pulley Assembly - Chain no . 40 K23-51158 - PC Board Nuts (1 Set) Q014 - Manual Crank Q029 - Cover HD Polyethylene SL Q400D - Omni Motor Harness Single Motor Q421 - ODC2000SL - Chassis DC Back-Up - Pulley, Idler, Molded Plastic, SL - Surge Suppressor...
HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA. Manual Crank not Included Power Back-Up Unit - Drive Belt DC SL (DM) - Bushing, 7/8" OD, .120" Wall x 1.950" - Limit Switch Bearing Holder - Electronic Metal Box - ... Assembly K75-50893 - Omni Motor Harness DM 312HM - Pulley DC2000 1/2 ID Idler Pulley Assembly - Chain no . 40 K23-51158 - PC Board Nuts (1 Set) Q014 - Manual Crank Q029 - Cover HD Polyethylene SL Q400D - Omni Motor Harness Single Motor Q421 - ODC2000SL - Chassis DC Back-Up - Pulley, Idler, Molded Plastic, SL - Surge Suppressor...